scholarly journals INTRAORAL SCANNING SYSTEMS - A CURRENT OVERVIEW

2020 ◽  
Vol 8 (10) ◽  
pp. 1214-1223
Author(s):  
Sheela Kannan ◽  
◽  
Chalakuzhiyil Abraham Mathew ◽  
Roseline Savarimuthu Paulraj ◽  
◽  
...  

Intraoral scanners (IOSs) are devices used for capturing direct optical impressions in dentistry. IOS eliminates the errors that are encountered with the conventional impression making procedures. The last decade has seen an increasing number of optical IOS devices, and these are based on different technologies. The objective of this review article is to discuss intraoral scanners with regards to its technology, generation systems, scanning paths, necessity of a powdering medium, accuracy (Trueness and precision), intermaxillary relationship registration, commercially available IOS, clinical recommendations, advantages, disadvantages, indications and contraindications. Digital impressions with IOS is likely going to be a routine procedure in dentistry in the near future.

2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Maria Francesca Sfondrini ◽  
Paola Gandini ◽  
Maurizio Malfatto ◽  
Francesco Di Corato ◽  
Federico Trovati ◽  
...  

Introduction. Intraoral scanners allow direct images of oral situation, with fewer steps than conventional impressions. The purpose of this study was to compare the accuracy of digital impressions, traditional impressions, and digitalization of full-arch gypsum models, to evaluate timing of different methods and finally to study perception of patients about conventional and digital impression techniques. Methods. Dental arches of fourteen patients were evaluated by alginate impression, titanium dioxide powder-free intraoral scanning (Trios, 3Shape), and digitalization obtained from gypsum models using the same scanner. Conventional and digital techniques were evaluated through measurements (lower and upper arch anteroposterior length, lower and upper intercanine distance, and lower and upper intermolar distance) with a caliber for analogic models and using a computer software for digital models (Ortho Analyzer, Great Lakes Orthodontics). In addition, chairside and processing times were recorded. Finally, each patient completed a VAS questionnaire to evaluate comfort. Statistical analyses were performed with ANOVA and Tukey tests for accuracy measurements and paired t-test for times and VAS scores. Significance was predetermined at P<0.05. Results. The measurements obtained with intraoral scanning, gypsum models after conventional impression, and digitalized gypsum models were not significantly different. Both chairside and processing times of digital scanning were shorter than the traditional method. VAS reporting patients comfort were significantly higher when evaluating digital impression. Conclusions. Intraoral scanners used for orthodontic applications provide useful data in clinical practice, comparable to conventional impression. This technology is more time efficient than traditional impression and comfortable for patients. Further evolution with more accurate and faster scanners could in future replace traditional impression methods.


2018 ◽  
Vol 55 (3) ◽  
pp. 376-379
Author(s):  
Smaranda Buduru ◽  
Anca Mesaros ◽  
Cristian Culcitchi ◽  
Marioara Moldovan ◽  
Doina Prodan ◽  
...  

The objective of this in-vitro study was to compare if there are any differences in the marginal fit of crowns fabricated by CAD/CAM technique. We used three different types of materials (two types of polymethylmetacrylate (PMMA) provided by two different manufacturers and one type of hybrid ceramic) and three different types of impressions: intraoral scanning, model scanning and conventional impression scanning. The crowns were subsequently measured with an electronic microscope at 1000X. Our results showed better results for the hybrid ceramic. The differences between the PMMA were not significant. There were no statistic differences with the ANOVA analysis between the scanning methods. Best combination in terms of marginal fit was found with hybrid ceramic and intraoral scanning.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bowen Ma ◽  
Xinxin Yue ◽  
Yujie Sun ◽  
Lingyan Peng ◽  
Wei Geng

Abstract Background To compare the accuracy of photogrammetry, intraoral scanning and conventional impression techniques for complete-arch implant rehabilitation. Methods A master cast containing 6 implant abutment replicas was fabricated. Group PG: digital impressions were taken 10 times using a photogrammetry system; Group IOS: intraoral scanning was performed to fabricate 10 digital impressions; Group CNV: splinted open-tray impression technique was used to fabricate 10 definitive casts. The master cast and conventional definitive casts were digitized with a laboratory reference scanner. For all STL files obtained, scan bodies were converted to implant abutment replicas using a digital library. The accuracy of a digitizer was defined by 2 main parameters, trueness and precision. "Trueness" was used to describe the deviation between test files and reference file, and "precision" was used to describe the closeness between test files. Then, the trueness and precision of three impression techniques were evaluated and statistically compared (α = 0.05). Results The median trueness was 24.45, 43.45 and 28.70 μm for group PG, IOS and CNV; Group PG gave more accurate trueness than group IOS (P < 0.001) and group CNV (P = 0.033), group CNV showed more accurate trueness than group IOS (P = 0.033). The median precision was 2.00, 36.00 and 29.40 μm for group PG, IOS and CNV; Group PG gave more accurate precision than group IOS (P < 0.001) and group CNV (P < 0.001), group CNV showed more accurate precision than IOS (P = 0.002). Conclusions For complete-arch implant rehabilitation, the photogrammetry system showed the best accuracy of all the impression techniques evaluated, followed by the conventional impression technique, and the intraoral scanner provided the least accuracy.


2021 ◽  
Vol 11 (10) ◽  
pp. 4612
Author(s):  
KweonSoo Seo ◽  
Sunjai Kim

Purpose: The aim of this study was to present a new method to analyze the three-dimensional accuracy of complete-arch dental impressions and verify the reliability of the method. Additionally, the accuracies of conventional and intraoral digital impressions were compared using the new method. Methods: A master model was fabricated using 14 milled polyetheretherketone cylinders and a maxillary acrylic model. Each cylinder was positioned and named according to its corresponding tooth position. Twenty-five definitive stone casts were fabricated using conventional impressions of the master model. An intraoral scanner was used to scan the master model 25 times to fabricate 25 digital models. A coordinate measuring machine was used to physically probe each cylinder in the master model and definitive casts. An inspection software was used to probe cylinders of digital models. A three-dimensional part coordinate system was defined and used to compute the centroid coordinate of each cylinder. Intraclass correlation coefficient (ICC) was evaluated to examine the reliability of the new method. Independent two sample t-test was performed to compare the trueness and precision of conventional and intraoral digital impressions (α = 0.05). Results: ICC results showed that, the new method had almost perfect reliability for the measurements of the master model, conventional and digital impression. Conventional impression showed more accurate absolute trueness and precision than intraoral digital impression for most of the tooth positions (p < 0.05). Conclusions: The new method was reliable to analyze the three-dimensional deviation of complete-arch impressions. Conventional impression was still more accurate than digital intraoral impression for complete arches.


Author(s):  
Alexander Schmidt ◽  
Leona Klussmann ◽  
Maximiliane A. Schlenz ◽  
Bernd Wöstmann

Abstract Objectives Due to the partly strongly differing results in the literature, the aim of the present study was to investigate a possible deformation of the mandible during mouth opening using an intraoral scanner (IOS) and a conventional impression for comparison with a reference aid. Materials and methods Four steel spheres were reversibly luted in the mandibular (n = 50) with a metallic reference aid at maximum mouth opening (MMO). Two digital impressions (Trios3), at MMO and at slightly mouth opening SMO and a conventional impression (Impregum), were taken as the measuring accuracy of the reference structure was already known. Difference between MMO-SMO for digital impressions and deviations between digital and conventional (SMO) were calculated. Furthermore, the angle between the normal vectors of two constructed planes was measured. Statistical analysis was performed with SPSS25. Results Deviations for linear distances ranged from −1 ± 3 μm up to 17 ± 78 μm (digital impressions, MMO-SMO), from 19 ± 16 μm up to 132 ± 90 μm (digital impressions, SMO), and from 28 ± 17 μm up to 60 ± 52 μm (conventional impressions, SMO). There were no significant differences for digital impressions (MMO-SMO), and there were significant differences between the conventional and digital impressions at SMO. Conclusions Based on the results of the present study, no mandibular deformation could be detected during mouth opening with regard to the digital impressions. The results were rather within the measuring tolerance of the intraoral scanner. Clinical relevance Based on the present study, no deformation of the mandibular during mouth opening could be observed at the level previously assumed. Therewith related, dental techniques related to a possible mandibular deformation therefore should be reconsidered.


Author(s):  
Jesús Peláez Rico ◽  
Jorge Cortés-Bretón Brinkmann ◽  
María Carrión Martín ◽  
Mabel Albanchez González ◽  
Celia Tobar Arribas ◽  
...  

The aim of this clinical report is to describe a maxillary full-arch implant supported restoration with immediate loading performed by means of an entirely digital workflow with photogrammetric system and intraoral scanning. A female patient with an edentulous maxillary arch attended the dental clinic seeking a maxillary fixed restoration. After treatment planning, six implants were placed using a surgical splint fabricated digitally by intraoral scanning of her previous removable prosthesis. Multi-unit abutments were fitted and two digital impressions were taken, one with a photogrammetric system for determining implant positions, and the other with an intraoral scanner for soft tissue registration. The acrylic resin structure of the immediate prosthesis was milled and placed within 8 hours of implant surgery. This provisional structure fitted correctly and provided adequate esthetics and function. Radiographic and clinical follow-up after 24 months observed adequate implant evolution.


Author(s):  
Jae‐Hoon Kim ◽  
Sung‐Ae Son ◽  
Hyeonjong Lee ◽  
Yeon‐Jee Yoo ◽  
Seoung‐Jin Hong ◽  
...  

2011 ◽  
Vol 05 (04) ◽  
pp. 472-477 ◽  
Author(s):  
Meltem Ozdemir Karatas ◽  
Ebru Demet Cifter ◽  
Didem Ozdemir Ozenen ◽  
Ali Balik ◽  
Erman Bulent Tuncer

ABSTRACTMaxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to.Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses. (Eur J Dent 2011;5:472-477)


2019 ◽  
Vol 41 (4) ◽  
pp. 539-549
Author(s):  
Natasha Silva Constancio ◽  
Maria Lucia Gomes Ferraz ◽  
Carmen Tzanno Branco Martins ◽  
Angiolina Campos Kraychete ◽  
Paulo Lisboa Bitencourt ◽  
...  

Abstract According to data from the last census of the Brazilian Society of Nephrology (SBN), the prevalence of hepatitis C virus (HCV) in Brazilian hemodialysis units (HU) is 3.3%, about three times higher than what is reported for the Brazilian general population. Often, professionals working in HU are faced with clinical situations that require rapid HCV diagnosis in order to avoid horizontal transmission within the units. On the other hand, thanks to the development of new antiviral drugs, the cure of patients with HCV, both in the general population and in patients with chronic kidney disease and the disease eradication, appear to be very feasible objectives to be achieved in the near future . In this scenario, SBN and the Brazilian Society of Hepatology present in this review article a proposal to approach HCV within HUs.