scholarly journals Comparison of the cleaning methods for the preparation of brachyuran crabs for scanning electron microscopy

2021 ◽  
Vol 25 (1) ◽  
pp. 1049-1057
Author(s):  
Marwa Osman ◽  
Wafaa Sallam ◽  
Fedekar Madkour
2019 ◽  
Vol 82 (11) ◽  
pp. 1965-1972 ◽  
Author(s):  
EWA PIETRYSIAK ◽  
JULIANNE M. KUMMER ◽  
INES HANRAHAN ◽  
GIRISH M. GANJYAL

ABSTRACT Large amounts of water used in the apple packing process, the presence of organic matter, and difficult-to-clean equipment are vectors for contaminating apples with foodborne pathogens, such as Listeria monocytogenes. There is a need to develop new cleaning methods for fresh apples and evaluate their antimicrobial efficacy. A series of surfactants of different chemical properties (cationic lauric arginate [LAE], anionic sodium dodecyl sulfate [SDS], and nonionic Tween 20 [T20]) alone and combined with peracetic acid (PAA) were evaluated for their efficiency in the removal of L. innocua, a surrogate of L. monocytogenes, from fresh apples. Whole fresh apples were inoculated with L. innocua (7 log CFU/mL) by a dipping method, dried, and subjected to wash treatments with selected cleaning solutions (water, PAA, PAA-LAE, PAA-SDS, and PAA-T20). The contact angle between the cleaning solutions and the surface of the apples was measured. The antimicrobial activity of the cleaning solutions and the efficacy of the cleaning treatment were evaluated by enumeration of L. innocua from treated apples and visualized by scanning electron microscopy. Stem bowl and calyx cavities of the apple harbored higher bacteria concentrations (∼4.82 log CFU per apple), compared with the equatorial section (∼2.66 log CFU per apple). Addition of 0.1% of selected surfactants led to a significant decrease in surface tension of cleaning solutions and allowed better spreading on the apple surface. Surfactants combined with PAA solution resulted in higher L. innocua reduction compared with PAA alone; however, their efficacy was limited. The most effective cleaning solution was PAA-T20, with reduction of approximately 2.2 log. Scanning electron microscopy imaging confirmed that most bacteria were harbored inside the surface irregularities. PAA alone and with surfactants caused damage and deformation of bacteria cells. Cleaning apples with PAA combined with surfactants may improve microbial safety in whole apples; however, the efficiency of the decontamination treatment can be reduced because of variations in apple morphology.


1997 ◽  
Vol 13 (04) ◽  
pp. 242-257
Author(s):  
Paul A. Blomquist

Equipment and technologies which could be used to clean three adjacent surfaces of shipbuilding steels simultaneously in a single pass prior to welding operations have been surveyed. Seven methods were evaluated: closed-circuit grit blasting, laser beam stripping, high-pressure water blasting, high velocity oxy-fuel flame stripping, multiple-head wire brushing, vacuum-shrouded needle-gunning, and carbon dioxide bead blasting. A commercially available vacuum-recovery recirculating grit-blast unit was evaluated in a shipyard trial. Results of the survey are presented in a comparison table and discussed in detail. For each method, production speed, approximate acquisition cost, consumables used, and environmental effects are considered. Surfaces produced by various cleaning methods were evaluated by visual examination and Scanning Electron Microscopy.


Author(s):  
P.S. Porter ◽  
T. Aoyagi ◽  
R. Matta

Using standard techniques of scanning electron microscopy (SEM), over 1000 human hair defects have been studied. In several of the defects, the pathogenesis of the abnormality has been clarified using these techniques. It is the purpose of this paper to present several distinct morphologic abnormalities of hair and to discuss their pathogenesis as elucidated through techniques of scanning electron microscopy.


Author(s):  
P.J. Dailey

The structure of insect salivary glands has been extensively investigated during the past decade; however, none have attempted scanning electron microscopy (SEM) in ultrastructural examinations of these secretory organs. This study correlates fine structure by means of SEM cryofractography with that of thin-sectioned epoxy embedded material observed by means of transmission electron microscopy (TEM).Salivary glands of Gromphadorhina portentosa were excised and immediately submerged in cold (4°C) paraformaldehyde-glutaraldehyde fixative1 for 2 hr, washed and post-fixed in 1 per cent 0s04 in phosphosphate buffer (4°C for 2 hr). After ethanolic dehydration half of the samples were embedded in Epon 812 for TEM and half cryofractured and subsequently critical point dried for SEM. Dried specimens were mounted on aluminum stubs and coated with approximately 150 Å of gold in a cold sputtering apparatus.Figure 1 shows a cryofractured plane through a salivary acinus revealing topographical relief of secretory vesicles.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Author(s):  
Ronald H. Bradley ◽  
R. S. Berk ◽  
L. D. Hazlett

The nude mouse is a hairless mutant (homozygous for the mutation nude, nu/nu), which is born lacking a thymus and possesses a severe defect in cellular immunity. Spontaneous unilateral cataractous lesions were noted (during ocular examination using a stereomicroscope at 40X) in 14 of a series of 60 animals (20%). This transmission and scanning microscopic study characterizes the morphology of this cataract and contrasts these data with normal nude mouse lens.All animals were sacrificed by an ether overdose. Eyes were enucleated and immersed in a mixed fixative (1% osmium tetroxide and 6% glutaraldehyde in Sorenson's phosphate buffer pH 7.4 at 0-4°C) for 3 hours, dehydrated in graded ethanols and embedded in Epon-Araldite for transmission microscopy. Specimens for scanning electron microscopy were fixed similarly, dehydrated in graded ethanols, then to graded changes of Freon 113 and ethanol to 100% Freon 113 and critically point dried in a Bomar critical point dryer using Freon 13 as the transition fluid.


Author(s):  
Jane A. Westfall ◽  
S. Yamataka ◽  
Paul D. Enos

Scanning electron microscopy (SEM) provides three dimensional details of external surface structures and supplements ultrastructural information provided by transmission electron microscopy (TEM). Animals composed of watery jellylike tissues such as hydras and other coelenterates have not been considered suitable for SEM studies because of the difficulty in preserving such organisms in a normal state. This study demonstrates 1) the successful use of SEM on such tissue, and 2) the unique arrangement of batteries of nematocysts within large epitheliomuscular cells on tentacles of Hydra littoralis.Whole specimens of Hydra were prepared for SEM (Figs. 1 and 2) by the fix, freeze-dry, coat technique of Small and Màrszalek. The specimens were fixed in osmium tetroxide and mercuric chloride, freeze-dried in vacuo on a prechilled 1 Kg brass block, and coated with gold-palladium. Tissues for TEM (Figs. 3 and 4) were fixed in glutaraldehyde followed by osmium tetroxide. Scanning micrographs were taken on a Cambridge Stereoscan Mark II A microscope at 10 KV and transmission micrographs were taken on an RCA EMU 3G microscope (Fig. 3) or on a Hitachi HU 11B microscope (Fig. 4).


Sign in / Sign up

Export Citation Format

Share Document