scholarly journals Maternal (oral) hydration increases amniotic fluid volume

2016 ◽  
Vol 12 (2) ◽  
Author(s):  
Aneela Umber

Objective:To determine the effect of maternal (oral) hydration on amniotic fluid volume in patients with third trimester oligohydramnios. Design: Interventional study. Place and Duration of Study: Department of Obs & Gynae Unit III, Sir Ganga Ram Hospital, Lahore from May 2002 to October 2002. Patients and Methods: Twenty five women with third trimester oligohydramnios (AFI ?5.0cm) and twenty five controls with normal amniotic fluid volume (AFI 8-24 cm) were prospectively recruited for this study. Maternal urine specific gravity and amniotic fluid index were determined before and after maternal hydration by asking them to drink 2 L of water in 2-4 hours before repeat amniotic fluid index and recorded on printed proformas. Results: Hydration increased amniotic fluid volume in women with oligohydramnios (mean change in amniotic fluid index 4.3 cm, 95% confidence interval 4.02 to 5.06; P value <0.001); as well as in women with normal fluid volume (mean change in Amniotic fluid index 2.7 cm, 95% confidence interval 2.23 to 3.21; P value <0.01). However, percentage increase in mean AFI was 58.6% in the oligohydramnios group, which was significantly greater (P value <0.05) than the percentage increase of 28.4% in control group. Hydration was associated with decrease in urine specific gravity in both groups. Conclusion: Maternal (oral) hydration increases AFV in women with oligohydramnios as well as in women with normal AFV and may be beneficial in the management of oligohydramnios.

2019 ◽  
Vol 26 (12) ◽  
pp. 2064-2069
Author(s):  
Saima Kiran ◽  
Adeela Ameen ◽  
Ayesha Akram ◽  
Mahwash Jamil

Objectives: To compare oral maternal hydration and intravenous infusion in women with third trimester isolated oligohydramnios in terms of mean change in amniotic fluid. Study Design: This is a Comparative Study. Setting: The study was conducted in Department of Gynecology, Pakistan Institute of Medical Sciences, Islamabad. Period: Between 1st May, 2015 to 31st July, 2016. Material & Methods: One hundred and fourteen pregnant females with singleton pregnancy, beyond 28 weeks gestation and AFI < 5cm were included. Placental insufficiency was ruled out on Doppler ultrasound of umbilical artery. Basal AFI and routine intake of fluid of all patients was noted. Patients were randomized either to receive oral maternal hydration or intravenous infusion. AFI measurement was repeated at 6th day after hydration therapy. Data was stratified for mean difference in improvement in amniotic fluid index. Results: One hundred and fourteen patients with mean age of 27.33 ± 3.87 years were included. 52 patients (45.6%) were primigravida and remaining 62 patients (54.4%) were multipara. Mean AFI value before treatment in sampled population was 3.35 ± 0.744 in oral hydration and 3.33 ± 0.787 in intravenous hydration (p=0.903). Mean AFI value after treatment was 5.53 ± 0.966 in oral hydration and 5.68 ± 1.490 in intravenous hydration, independent sample test showed non-significant (p=0.903) difference. Mean increase in AFI before and after treatment was cross tabulated and resultant difference was significant (p value=0.001). There is no effect of age, gestational age, history of oligohydramnios on improvement in amniotic fluid index. Conclusion: Both treatment modalities i.e. oral maternal hydration and intravenous infusion are effective in terms of improvement of amniotic fluid index but there is no difference in both treatments in pregnant females with isolated oligohydramnios in 3rd trimester at current sample size.


Author(s):  
Mumal Nagwani ◽  
P.K. Sharma ◽  
Anita Rani ◽  
Urmila Singh ◽  
Seema Mehrotra

Introduction: Placenta is the most important temporary organ during pregnancy. Healthy placenta is utmost needed for a healthy baby. Ultrasonography is the preferred modality for antenatal evaluation of placenta. Amniotic fluid plays a major role in fetal growth and development and for adequate amniotic fluid volume, a normally developed placenta is required. Thus, Placental parameters may indirectly affect the amniotic fluid volume which plays a crucial role for fetal development. Material & Methods: One hundred (100) antenatal cases were recruited for the present study. Those women who were with uncomplicated, singleton pregnancy of more than 26 weeks and gave their written informed consent, were taken as subjects. Thickness of the placenta was measured at the level of cord insertion. Amniotic Fluid Index (AFI) was obtained by adding the vertical lengths of deepest fluid pockets in four uterine quadrants. Results: The mean placental thickness in third trimester was found as 3.90±1.1cm and mean AFI as 125.20±38.5. Conclusion: A linear but inverse correlation was observed between placental thickness and amniotic fluid index.


Author(s):  
Humaira Zafar ◽  
Mubashra Naz ◽  
Umber Fatima ◽  
Uzma Shahzad ◽  
Anees Fatima ◽  
...  

Background: To study the effect of oral and intravenous maternal hydration in patients with isolated oligohydramnios in terms of mean change in amniotic fluid.Methods: A total number of 38 patients included in the study which fulfill the selection criteria.  Patients were randomly divided in two groups. Amniotic fluid index (AFI) of all patients was measured before the hydration therapy according to the method of Phelan et al.  In maternal oral hydration (Group A), every patient was instructed to drink two liters of water over two hours daily for 1 week. In intravenous hydration (Group B), every woman infused two liters of 0.9% normal saline in two hour daily for 1 week. After 48 hours and 1 week of oral and intravenous hydration, the AFI was reassessed by the same observer. Patients were monitored closely for sign and symptoms of fluid overload. Data was stratified for mean difference in improvement in amniotic fluid index.Results: After oral hydration therapy AFI was 5.926±0.4593 after 48 hours and 8.286±0.6000 after 7 days in Group A. In Group B AFI was 5.784±0.4622 after 48 hours and 7.868±0.2810 after 7 days of intravenous hydration. P value after 48 hours is 0.348 and p=0.014 after 7 days means oral hydration therapy significantly increase amniotic fluid index.Conclusions: Oral maternal hydration significantly increase the amniotic fluid index in patients with isolated oligohydramnios. It is simple, safe and non-invasive method.


2021 ◽  
Vol 17 ◽  
Author(s):  
Roopa Padavagodu Shivananda ◽  
Rekha Anbu ◽  
Shubha Rao ◽  
Nivedita Hegde ◽  
Anjali Suneel Mundkur ◽  
...  

Background: The best method of estimation of amniotic fluid volume is a matter of ongoing debate. Objectives: To determine the perinatal & maternal outcomes in pregnant patients when the amniotic fluid volume was assessed by the amniotic fluid index (AFI) in comparison to the single deepest vertical pocket (SDVP). Methods: We studied abnormal Cardiotocograph, meconium stained amniotic fluid, birth weight <2.5kg, Apgar score at 5 min <7, cord blood pH <7.2 & necessity for NICU admission as perinatal outcomes. Rate of diagnosis of oligohydramnios, induction of labor for oligohydramnios & mode of delivery were observed in maternal outcomes. Results: Of the 697 pregnant patients recruited, 353 were in the AFI and 344 in the SDVP group. Perinatal outcomes were similar in both. In the AFI group, the number of women diagnosed with oligohydramnios was higher (p = 0.0333) & the rate of induction was also higher (p = 0.003378). Vaginal deliveries were more in the SDVP group. The Receiver Operating Characteristic curves showed statistically significant correlation with NICU stay, birth-weight, and mode of delivery. While an AFI of >5cm and SDVP of >1.9cm had good sensitivity in predicting babies with a birth weight of ≥ 2.5kg and avoiding NICU admissions, an AFI of > 5.8cm and an SDVP of > 1.9 cm had a sensitivity of around 80% in predicting successful vaginal deliveries. Conclusion: The SDVP method has a slight edge over the AFI in terms of lower inductions and higher vaginal deliveries with comparable perinatal outcomes.


2017 ◽  
Vol 13 (4) ◽  
pp. 401-405
Author(s):  
Rajiv Shah ◽  
Paban Sharma

Background & Objectives: The measurement of amniotic fluid volume (AFV) has been an important component of antenatal evaluation of fetal well being. The most commonly used methods are by amniotic fluid index technique (AFI) and single deepest pool method (SDVP). Both the methods employ ultrasound for AFV measurement. The objective of this study is to compare the usefulness of AFI and SDVP method in assessing amniotic fluid volume for predicting adverse perinatal outcome.Materials & Methods: This is a hospital based prospective comparative study. The patient whose amniotic fluid was measured by SDVP technique was study group and that by AFI was comparison group. Any case with high risk factor was excluded from the study. First case was decided by lottery and then alternately one case was kept in study group and the other in comparative group. If the women did not deliver within 1 week the measurements was retaken and the final values was used for analysis.AFI was estimated as described by Phelan and colleagues and SDVP as described by Manning. Data collection was started after the approval of Institution review board. This study was conducted at Patan Academy of Health Sciences. Duration of data collection was 3 months, Asadh –Bhadra, 2071.Results: A total of one hundred and fifty four cases which met the inclusion criteria were taken. Incidence of oligohydramnios by SDVP method was 10.4 % by SDVP technique and by AFI method it was 18.2 %. There was no statistical significant difference between the two groups in terms of rate of induction, mode of delivery, meconium staining of liquor, fetal heart rate tracings, APGAR score at 5 mins and admission to special care baby unit.Conclusion: In non-high risk pregnancy AFI technique detects slightly more number of oligohydramnios as compared to SDVP technique without apparently any difference in perinatal outcome.


Author(s):  
Jeyamani B. ◽  
Anurekha J. P. ◽  
Arun Daniel J.

Background: Oligohydramnios is the term coined for a condition where the amount of liquor amnii is less than 200 ml at term. Using an ultrasonogram, oligohydramnios can be deliberated when the vertical pocket of liquor is less than 2 cm or when amniotic fluid index (AFI) is less than 5 cm. Oligohydramnios is reported to occur in 1 to 5% of total pregnancies. It has been associated with adverse maternal and foetal outcomes.Methods: This hospital-based follow-up study was conducted among 540 pregnant women at 37 weeks attending to the Department of Obstetrics and Gynaecology for a period of 1 year from January to December 2018. All included pregnant women were subjected to routine ultrasound examination and assessment of amniotic fluid volume using Amniotic fluid index.Results: The incidence of oligohydramnios was 17.04% (n=92) among the included women and 62% (n=57) among them were primigravida. Among those women diagnosed with Oligohydramnios, the caesarean section rate was 56.5% (n=52), the common indications for LSCS being fetal distress 44. 2% (n=23) and IUGR 34.6% (n=18). The oligohydramnios pregnancies had more associated post-dated deliveries (28.3%), pregnancy induced hypertension (10.9%) and gestational diabetes (8.7%). It was also associated with higher incidence of low birth weight (27.2%), NICU admissions (32.6%), congenital anomalies (3.3%) and fetal deaths (5.4%).Conclusions: The study showed that an amniotic fluid index of less than 5 at term was associated with adverse maternal and perinatal pregnancy outcomes emphasizing the importance of amniotic fluid volume surveillance during the antenatal period.


1992 ◽  
Vol 9 (05/06) ◽  
pp. 315-318 ◽  
Author(s):  
Iffath Hoskins ◽  
Peter McGovern ◽  
Steven Ordorica ◽  
Faith Frieden ◽  
Bruce Young

Sign in / Sign up

Export Citation Format

Share Document