scholarly journals Evaluation of the drinking water quality surveillance system in the metropolitan region of Rio de Janeiro

Author(s):  
Clarissa Perez Faria ◽  
Ricardo Almendra ◽  
Gisele Silva Dias ◽  
Paula Santana ◽  
Maria do Céu Sousa ◽  
...  

Abstract The present work evaluated the surveillance of the drinking water quality information system database and correlated the findings of the microbiological analysis with the distribution of intestinal protozoa from the metropolitan region of Rio de Janeiro. From the database, we obtained 1,654 georeferenced monitoring stations that were used in the analysis. The results indicate that the minimum number of samples collected per parameter (free residual chlorine, turbidity, counts of total and fecal coliforms (Escherichia coli)) was not fulfilled, the collection of samples throughout the year was irregular and the representability of sampling points considered strategic was low (48% of municipalities). Besides, municipalities with a high prevalence for intestinal parasite protozoa were also the ones that had the highest counts for coliforms and the reverse can also be observed, indicating a transmission through contaminated drinking water. Despite the increased participation of municipalities in water surveillance actions during the studied period, it is necessary to implement managerial measures to improve the system, aiming to correct flaws and inconsistencies in the application of the water quality monitoring protocol.

Author(s):  
Yu.A. Novikova ◽  
I.O. Myasnikov ◽  
A.A. Kovshov ◽  
N.A. Tikhonova ◽  
N.S. Bashketova

Summary. Introduction: Drinking water is one of the most important environmental factors sustaining life and determining human health. The goal of the Russian Federal Clean Water Project is to improve drinking water quality through upgrading of water treatment and supply systems using advanced technologies, including those developed by the military-industrial complex. The most informative and reliable sources of information for assessing drinking water quality are the results of systematic laboratory testing obtained within the framework of socio-hygienic monitoring (SGM) and production control carried out by water supply organizations. The objective of our study was to formulate approaches to organizing quality monitoring programs for centralized cold water supply systems. Materials and methods: We reviewed programs and results of drinking water quality laboratory tests performed by Rospotrebnadzor bodies and institutions within the framework of SGM in 2017–2018. Results: We established that drinking water quality monitoring in the constituent entities of the Russian Federation differs significantly in the number of monitoring points (566 in the Krasnoyarsk Krai vs 10 in Sevastopol) and measured indicators, especially sanitary and chemical ones (53 inorganic and organic substances in the Kemerovo Region vs one indicator in the Amur Region). Discussion: For a more complete and objective assessment of drinking water quality in centralized cold water supply systems, monitoring points should be organized at all stages of water supply with account for the coverage of the maximum number of people supplied with water from a particular network. Thus, the number of points in the distribution network should depend, inter alia, on the size of population served. In urban settlements with up to 10,000 inhabitants, for example, at least 4 points should be organized while in the cities with more than 3,000,000 inhabitants at least 80 points are necessary. We developed minimum mandatory lists of indicators and approaches to selecting priority indices to be monitored at all stages of drinking water supply.


Author(s):  
Kanij Fatema Nishan ◽  
Nilufa Yeasmin ◽  
Urmi Rani Devi ◽  
Sumiya Akter ◽  
Md. Abu Bakar ◽  
...  

Chattogram is the second most populated city in Bangladesh. This port city faces a serious threat mainly due to the lack of safe drinking water. This study was conducted for determining drinking water quality of groundwater sources in Chattogram city. The study was performed in the BCSIR laboratory, Chattogram. It was carried out for a period of six months from 1st July, 2018 to 31th December, 2018. Total six water samples were collected from three different locations (Baluchora, C&B colony and Khulshi area). Each sampling location consists of two separate sampling points. Physicochemical parameters of the collected samples like Temperature, pH, Electrical Conductivity (EC), Total dissolved solid (TDS), Hardness, Turbidity and concentration of Cl, As, Mn, Fe, Pb, Cr and Cd were examined. Microbial parameters like Total Coliform (TC) were also measured. All the analyzed parameters compared with BSTI and WHO drinking water quality standards to understand the overall ground water quality status of the study area. The results reveal that water samples in almost all locations were contaminated with microbial contamination and that the range of physico-chemical parameters was not adequate for consumption. Preliminary treatments like boiling, filtering etc are required before using groundwater for drinking and the necessary measures must be taken for a safe alternative source of drinking water.


Author(s):  
L. O. Bobor ◽  
C. M. Umeh

The indiscriminate disposal of industrial effluents and solid wastes in surface water bodies is detrimental to humans and aquatic organisms. Water quality monitoring is critical to identify pollutants of concern and develop effective management strategies. Hence, this study was conducted to assess the impact of waste disposal on the water quality of Aba Waterside River, Ogbor hill, Aba. Grab samples were collected upstream, midstream and downstream and some physicochemical and microbiological parameters were analyzed in accordance with standard methods for the analysis of water and wastewater. The results were compared with the Nigerian standard for drinking water quality and the national environmental effluent limitation regulations. Turbidity levels (10 -31mg/l) exceeded the maximum permissible levels for drinking water (5mg/l) and may be associated with higher levels of embedded disease-causing microbes and potentially harmful organic and inorganic substances. The biological oxygen demand midstream (1960mg/l) was remarkably high due to the effluent discharged from the abattoirs at that point. Fecal coliforms (3-198MPN/100ml) were detected in all samples, indicating the presence of other potentially harmful microorganisms. The findings of this study indicate that the water is unsuitable for direct drinking water purposes and stringent water quality control measures should be implemented.


Author(s):  
Sajjad Haydar ◽  
Obaidullah Nadeem ◽  
Ghulam Hussain ◽  
Haroon Rashid ◽  
Rashid Majeed

A study was conducted to evaluate the drinking water quality of Gujranwala city. Samples were collected from 16 locations including: 4 tube wells, 4 overhead reservoirs (OHR) and 8 house connections. Twelve physicochemical and two bacteriological parameters were tested, before and after monsoon and compared with National Standards for Drinking Water Quality (NSDWQ). The results demonstrated that most of the physicochemical parameters, except lead, nickle and chromium were within NSDWQ before and after monsoon. Bacteriological and heavy metal contamination was found before and after the monsoon. Possible reasons of contamination are: no disinfection, old and leaking water pipes, poor drainage duringmonsoon and possible cross connections between water and sewerage lines. It is recommended to practice disinfection, laying of water and sewerage pipes on opposite sides of streets and periodic water quality monitoring.


2021 ◽  
Vol 9 ◽  
Author(s):  
Chiqian Zhang ◽  
Jingrang Lu

Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).


Author(s):  
IO Myasnikov ◽  
YuA Novikova ◽  
OS Alenteva ◽  
GB Yeremin ◽  
PA Ganichev

Summary. Introduction: In order to conduct a more precise and objective assessment of drinking water quality in the centralized cold water supply systems, it is essential to increase the coverage of population with laboratory control. It is therefore expedient to consider the possibility of using production control data collected within the drinking water quality monitoring system and including them in statistical reporting forms of Rospotrebnadzor for subsequent accounting when assessing the implementation of the Russian Federal Clean Water Project within the National Ecology Project. Our objective was to substantiate requirements for organization of production control of drinking water with considering a further use of its results in assessing drinking water quality. The materials of the research included current regulations and literature data. We applied methods of sanitary and epidemiologic expert examination, assessment and survey as well as methods of systemic and content analysis. Results: To evaluate the supply of the population with high-quality drinking water, it is important to consider not only test results collected within the framework of the federal state sanitary and epidemiologic surveillance but also the results of production control carried out by legal entities and individual entrepreneurs operating centralized cold water supply systems. However, organization of production control and the use of its results is usually associated with such problems as the choice of the most representative sampling points, identification of a sufficient list of controlled indicators, quality of results, etc. Conclusions: Before including the results of drinking water quality production control in the drinking water quality monitoring system, it is necessary to set the requirements for selecting monitoring sites, analytes, frequency of testing, etc. To legitimize the use of production control results, it is important to develop regulations that oblige organizations carrying out production control of drinking water quality to submit their results to Rospotrebnadzor bodies and institutions for their use in comprehensive drinking water quality assessments.


Waterlines ◽  
1994 ◽  
Vol 13 (2) ◽  
pp. 8-10 ◽  
Author(s):  
Mukundan Sugunan Pillay ◽  
Mustafa Selim ◽  
Debbie Siru

2014 ◽  
Vol 44 (12) ◽  
pp. 1370-1421 ◽  
Author(s):  
Muinul H. Banna ◽  
Syed Imran ◽  
Alex Francisque ◽  
Homayoun Najjaran ◽  
Rehan Sadiq ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document