scholarly journals Scum yield and effectiveness of a hydrostatic removal device: case study of Laboreaux STP

2017 ◽  
Vol 12 (1) ◽  
pp. 202-210 ◽  
Author(s):  
A. P. Rosa ◽  
A. V. Santos ◽  
A. D. U. C. Schmidt ◽  
J. M. Borges ◽  
C. A. L. Chernicharo

This paper aimed to evaluate the effectiveness of a device to remove scum from the inner part of gas-liquid-solid separators of a full-scale upflow anaerobic sludge blanket reactor treating domestic sewage, as well as determining the scum yield coefficient for different reactors’ operating conditions. The experiments were carried out at the Laboreaux sewage treatment plant (Itabira, Minas Gerais, Brazil) and the effectiveness of the scum removal device was fully demonstrated, with median efficiencies ranging from 65 to 90%. The average scum yield varied from 6.8 to 14.6 mL of scum formed per kg COD applied.

2017 ◽  
Vol 76 (8) ◽  
pp. 2003-2014 ◽  
Author(s):  
Pollyane Diniz Saliba ◽  
Marcos von Sperling

The objective of this study was to evaluate the behaviour of a system comprising an upflow anaerobic sludge blanket reactor followed by activated sludge to treat domestic sewage. The Betim Central sewage treatment plant, Brazil, was designed to treat a mean influent flow of 514 L/s. The study consisted of statistical treatment of monitoring data from the treatment plant covering a period of 4 years. This work presents the concentrations and removal efficiencies of the main constituents in each stage of the treatment process, and a mass balance of chemical oxygen demand (COD) and nitrogen. The results highlight the good overall performance of the system, with high mean removal efficiencies: BOD (biochemical oxygen demand) (94%), COD (91%), ammonia (72%) and total suspended solids (92%). As expected, this system was not effective for the removal of nutrients, since it was not designed for this purpose. The removal of Escherichia coli (99.83%) was higher than expected. There was no apparent influence of operational and design parameters on the effluent quality in terms of organic matter removal, with the exceptions of the BOD load upstream of the aeration tank and the sludge age in the unit. Results suggest that this system is well suited for the treatment of domestic sewage.


2011 ◽  
Vol 63 (4) ◽  
pp. 680-688 ◽  
Author(s):  
R. Walia ◽  
P. Kumar ◽  
I. Mehrotra

In India, recently, upflow anaerobic sludge blanket (UASB) based sewage treatment plants (STPs) have come up in a big way. Sequence adopted: screens- grit chambers- UASB reactors followed by one-day detention ponds (DP). Performance of DPs located at five STPs (27–70 ML/d) was evaluated over a period of one year from July 2004 to July 2005. The installation of these non-algal ponds reduced land requirement, but from treatment point of view it at best offered only removal of solids washed out of the UASB reactor. Total coliform count in the effluent from ponds ranging from 106 to 109 MPN/100 mL is more than the maximum permissible limit of 10,000 MPN/100 mL. A need has, therefore, been felt to evaluate the possibility of aerating the effluent from UASBR. During aeration, ORP and DO increase, whereas COD and BOD decrease. In a continuous aeration ~50% reduction in COD and nearly 50% increase in DO saturation (DO/DOs) can be achieved by increasing ORP from −100 to 122 mV. Regression equation established between ORP and COD/CODi & DO/DOs may find wide application.


1998 ◽  
Vol 38 (8-9) ◽  
pp. 189-195 ◽  
Author(s):  
Ricardo Franci Gonçalves ◽  
Vera Lúcia de Araújo ◽  
Carlos Augusto L. Chernicharo

This paper presents exploratory results on the association of an Upflow Anaerobic Sludge Blanket - UASB reactor (46 L) and a submerged aerated biofilter – BF (6.3 L) for domestic sewage treatment. The experimental period extended for 322 days, during which the hydraulic and organic loads were gradually increased in both reactors. Having the UASB as a reference, the following hydraulic loads were tested: 0.4 m3/m2.h (θ = 16 h); 0.6m3/m2.h (θ = 10h); 0.8 m3/m2.h (θ = 8 h); 1.0 m3/m2.h (θ = 6 h) and 1.45 m3/m2.h (θ = 4h). During the experiments carried out with the UASB reactor operating at a hydraulic detention time of 6 hours, related to a θ < 11′ in the granular media of the BF, the mean removal efficiency in terms of SS, BOD5 and COD, in both reactors, were respectively 94%, 96% and 91%. The final effluent, related to the BF effluent, presented the following mean characteristics: SS = 10 mg/L, BOD5 = 9 mg/L and COD = 38 mg/L. The results obtained in the last phase of the experiments, when the hydraulic load in the UASB reactor reached 1.45 m3/m2.h (θ = 4h), were similar to those obtained in the previous phase. These results demonstrate that submerged aerated biofilters can be considered a viable alternative for the post-treatment of effluents from UASB reactors treating domestic sewage. These reactors are capable of being operated with very short hydraulic detention times.


2017 ◽  
Vol 75 (7) ◽  
pp. 1659-1666 ◽  
Author(s):  
T. Bressani-Ribeiro ◽  
E. M. F. Brandt ◽  
K. G. Gutierrez ◽  
C. A. Díaz ◽  
G. B. Garcia ◽  
...  

This paper aims to present perspectives for energy (thermal and electric) and nutrient (N and S) recovery in domestic sewage treatment systems comprised of upflow anaerobic sludge blanket (UASB) reactors followed by sponge-bed trickling filters (SBTF) in developing countries. The resource recovery potential was characterized, taking into account 114 countries and a corresponding population of 968.9 million inhabitants living in the tropical world, which were grouped into three desired ranges in terms of cities’ size. For each of these clusters, a technological arrangement flow-sheet was proposed, depending on their technical and economic viability from our best experience. Considering the population living in cities over 100, 000 inhabitants, the potential of energy and nutrient recovery via the sewage treatment scheme would be sufficient to generate electricity for approximately 3.2 million residents, as well as thermal energy for drying purposes that could result in a 24% volume reduction of sludge to be transported and disposed of in landfills. The results show that UASB/SBTF systems can play a very important role in the sanitation and environmental sector towards more sustainable sewage treatment plants.


2019 ◽  
Vol 35 (4) ◽  
pp. 1352-1359
Author(s):  
Nimeshchandra Vasanji Vashi ◽  
Navinchandra Champaklal Shah ◽  
Kishor Ratilal Desai

Upflow Anaerobic Sludge Blanket (UASB) process is a popular process for treatment of sewage in India due to its low power requirement. However, UASB system has many limitations in terms of removal of carbon, nutrients and pathogens. This requires post treatment after UASB to meet the treated water quality standards. Current treatment processes adopted for the post-treatment of anaerobically treated sewage, especially the full-scale UASB reactors in Surat, India are presented. Two full scale treatment plants with different UASB post treatment processes viz., Extended Aeration and Moving Bed Biological Reactor (MBBR) are selected for studies. A pilot study was carried out in a full scale Sewage Treatment Plant (STP) to study the performance of Sequential Batch Reactor (SBR) for treatment of UASB treated sewage and the results are reported for period of Three months. Inlet and outlet parameters such as Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), etc. for post UASB biological process are presented. The performance of the SBR process was observed to be better among all the processes studied.


1996 ◽  
Vol 33 (3) ◽  
pp. 73-84 ◽  
Author(s):  
J. T. de Sousa ◽  
E. Foresti

Domestic sewage treatment in up-flow anaerobic sludge blanket (UASB) reactors has presented significant results in tropical regions. This reactor configuration has proven to be efficient in removing organic matter and total suspended solids as well as in producing smaller amounts of excess sludge than conventional aerobic reactor. On the other hand, its effluent often requires to be post-treated in order to achieve the emission standards. This paper is concerned with the alternative proposed here for treating domestic sewage in a combined anaerobic-aerobic system composed of an UASB reactor followed by sequencing batch aerobic reactors (SBR). In such a system, the UASB reactor removes considerable fraction of the influent organic matter, while the SBRs oxidize part of the remaining organic matter and ammonium nitrogen. A proper system operation would also permit the removal of nutrients (N and P). In order to investigate on the performance of this system for sewage treatment, a bench scale installation fed with synthetic substrate simulating domestic sewage was operated continuously during 38 weeks. The results permit to confirm the hypothesis proposed, since the system has consistently produced high quality effluents (BOD5 and VSS lower than 10 mg.L-1). The results also indicate that such combined anaerobic-aerobic system compete favorably with conventional aerobic systems in three essential cost features: energy consumption, excess sludge production and nutrient removal.


Author(s):  
Narendra Pal Gole

The implementation of wastewater treatment plants has been a challenge for most countries. Economic resources, political will, institutional strength, and cultural background are important factors that define the trajectory of pollution control in many countries. Technology is sometimes mentioned as one of the reasons hindering further development. Therefore, a key objective of this research is to evaluate the performance of a plant based on the 345 MLD Upflow Anaerobic Sludge Blanket (UASB) technology by analyzing the physical and chemical parameters of the water treated by UASB to evaluate the performance of the plant located. at Bharwara Tech from Gomti Nagar Lucknow. In this study, the performance of the wastewater treatment plant and the UASB reactor was calculated. Wastewater is mixed with domestic wastewater, so the concentration of BOD and COD is relatively low. The amount of biogas produced by the UASB reactor is also less than its design value. All STP inlet and outlet water concentration results are displayed graphically.


Sign in / Sign up

Export Citation Format

Share Document