Application of microfiltration for reuse of backwash water in a conventional water treatment plant - a case study

2001 ◽  
Vol 1 (5-6) ◽  
pp. 199-206 ◽  
Author(s):  
H. Song ◽  
X. Fan ◽  
Y. Zhang ◽  
T. Wang ◽  
Y. Feng

In conventional drinking water treatment processes, the amount of the filter backwash water covers nearly 3% of the total production. To reduce the water loss and waste discharge in the conventional drinking water treatment process, the Macao Water Supply Co. Ltd (SAAM) plans to recover the backwash water by Microfiltration (MF) membrane process as water resources are scarce and new environmental regulations are mandated in Macao. Generally, the filter backwash water from the conventional water treatment plant with sedimentation process is recycled to the source water to be treated again under certain conditions, and the sedimentation tank discharges most of the sludge. However, it is possible to recycle the backwash water directly to the inlet for direct filtration process due to the limitation of inlet turbidity. This paper describes how to apply MF technology to treat the backwash water of the direct filtration plant and to optimize MF operation. Without pre-treatment of the settling basin for backwash water, the operation of the MF pilot plant is proved to be stable and the permeate quality can meet EU drinking water standards. The pilot study shows that it is both economically and technically feasible to adopt MF technology in backwash water treatment. The main parameters to test MF process include flux, chemical cleaning duration and transmembrane pressure (TMP). They are 150-200 L/m2.h, 20 days and <1 bar respectively. The estimated cost including O&M and investment for a 1320-1760 m3/d backwash water treatment plant is USD 0.126-0.168/m3.

2019 ◽  
Vol 19 (8) ◽  
pp. 2330-2337
Author(s):  
Susumu Hasegawa ◽  
Yasuhiro Tanaka ◽  
Naokazu Wake ◽  
Ryosuke Takagi ◽  
Hideto Matsuyama

Abstract Recently, membrane filtration systems have become increasingly common in drinking water treatment plants. In this industry, preventing membrane fouling is of utmost importance. Many studies on the relationship between raw water components and membrane fouling have been performed in laboratory conditions. However, very few studies have analyzed the components of foulants on the fouled membrane as operated in actual drinking water treatment plants. By analyzing these components in plant-conditions, membrane fouling will be more effectively prevented. In this study, we analyzed the components of foulants extracted with 0.1 N NaOH from a fouled membrane operated in a drinking water treatment plant in Japan. Our analysis revealed that the main foulants were humic substances. In order to dissolve the accumulated humic substances, additional chemical cleaning was attempted with 500 ppm sodium hypochlorite. As a result, it was found that humic substances were dissolved and filtration resistance significantly decreased. Additionally, the removal of inorganic foulants was also greater after chemical cleaning with 500 ppm sodium hypochlorite, as inorganic foulants trapped within humic substances were released to the membrane surface as hydroxides by the additional sodium hypochlorite cleaning and were dissolved by the periodic citric acid cleaning.


RSC Advances ◽  
2016 ◽  
Vol 6 (80) ◽  
pp. 76922-76932 ◽  
Author(s):  
Bingwei Hou ◽  
Tao Lin ◽  
Wei Chen

Recycling the filter backwash water of a drinking water treatment plant (DWTP) was considered as a feasible method to enhance the efficiencies of pollutant removal and water conservation.


2001 ◽  
Vol 1 (5-6) ◽  
pp. 207-214
Author(s):  
A. Brügger ◽  
K. Voßenkaul ◽  
T. Melin ◽  
R. Rautenbach ◽  
B. Golloing ◽  
...  

Membrane filtration allows safe retention of microorganisms when treating filter backwash water from conventional drinking water filters. The permeate of the membrane plant can thus be reused to produce drinking water. The benefits are a higher yield of the drinking water treatment plant and a minimised wastewater production. This paper discusses the results of a pilot study, cost data and full-scale operation experiences concerning the application of ultrafiltration to treat filter backwash water. The effectiveness of ultrafiltration was assessed with regard to flux, cost and permeate quality.


2016 ◽  
Vol 16 (4) ◽  
pp. 922-930 ◽  
Author(s):  
L. Richard ◽  
E. Mayr ◽  
M. Zunabovic ◽  
R. Allabashi ◽  
R. Perfler

The implementation and evaluation of biological nitrification as a possible treatment option for the small-scale drinking water supply of a rural Upper Austrian community was investigated. The drinking water supply of this community (average system input volume: 20 m3/d) is based on the use of deep anaerobic groundwater with a high ammonium content of geogenic origin (up to 5 mg/l) which must be treated to prevent the formation of nitrites in the drinking water supply system. This paper describes the implementation and operation of biological nitrification despite several constraints including space availability, location and financial and manpower resources. A pilot drinking water treatment plant, including biological nitrification implemented in sand filters, was designed and constructed for a maximum treatment capacity of 1.2 m3/h. Online monitoring of selected physicochemical parameters has provided continuous treatment performance data. Treatment performance of the plant was evaluated under standard operation as well as in the case of selected malfunction events.


2017 ◽  
Vol 29 (12) ◽  
pp. 2665-2670
Author(s):  
Soleha Mohamat Yusuff ◽  
K.K. Ong ◽  
W.M.Z. Wan Yunus ◽  
A. Fitrianto ◽  
M. Ahmad ◽  
...  

Author(s):  
Ivone Vaz-Moreira ◽  
Vânia Figueira ◽  
Ana R. Lopes ◽  
Alexandre Lobo-da-Cunha ◽  
Cathrin Spröer ◽  
...  

A Gram-positive, aerobic, non-motile, endospore-forming rod, designated DS22T, was isolated from a drinking-water treatment plant. Cells were catalase- and oxidase-positive. Growth occurred at 15–37 °C, at pH 7–10 and with <8 % (w/v) NaCl (optimum growth: 30 °C, pH 7–8 and 1–3 % NaCl). The major respiratory quinone was menaquinone 7, the G+C content of the genomic DNA was 36.5 mol% and the cell wall contained meso-diaminopimelic acid. On the basis of 16S rRNA gene sequence analysis, strain DS22T was a member of the genus Bacillus. Its closest phylogenetic neighbours were Bacillus horneckiae NRRL B-59162T (98.5 % 16S rRNA gene sequence similarity), Bacillus oceanisediminis H2T (97.9 %), Bacillus infantis SMC 4352-1T (97.4 %), Bacillus firmus IAM 12464T (96.8 %) and Bacillus muralis LMG 20238T (96.8 %). DNA–DNA hybridization, and biochemical and physiological characterization allowed the differentiation of strain DS22T from its closest phylogenetic neighbours. The data supports the proposal of a novel species, Bacillus purgationiresistans sp. nov.; the type strain is DS22T ( = DSM 23494T = NRRL B-59432T = LMG 25783T).


Sign in / Sign up

Export Citation Format

Share Document