scholarly journals Sensor placement for leak detection and location in water distribution networks

2014 ◽  
Vol 14 (5) ◽  
pp. 795-803 ◽  
Author(s):  
R. Sarrate ◽  
J. Blesa ◽  
F. Nejjari ◽  
J. Quevedo

The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This work presents an optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of diagnosability while the sensor configuration cost satisfies a budgetary constraint. To efficiently handle the complexity of the distribution network an efficient branch and bound search strategy based on a structural model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed in a District Metered Area in the Barcelona water distribution network.

2018 ◽  
Vol 28 (2) ◽  
pp. 283-295 ◽  
Author(s):  
Marcos Quiñones-Grueiro ◽  
Cristina Verde ◽  
Alberto Prieto-Moreno ◽  
Orestes Llanes-Santiago

Abstract The water loss detection and location problem has received great attention in recent years. In particular, data-driven methods have shown very promising results mainly because they can deal with uncertain data and the variability of models better than model-based methods. The main contribution of this work is an unsupervised approach to leak detection and location in water distribution networks. This approach is based on a zone division of the network, and it only requires data from a normal operation scenario of the pipe network. The proposition combines a periodic transformation and a data vector extension together with principal component analysis of leak detection. A reconstruction-based contribution index is used for determining the leak zone location. The Hanoi distribution network is employed as the case study for illustrating the feasibility of the proposal. Single leaks are emulated with varying outflow magnitudes at all nodes that represent less than 2.5% of the total demand of the network and between 3% and 25% of the node’s demand. All leaks can be detected within the time interval of a day, and the average classification rate obtained is 85.28% by using only data from three pressure sensors.


2005 ◽  
Vol 5 (2) ◽  
pp. 31-38
Author(s):  
A. Asakura ◽  
A. Koizumi ◽  
O. Odanagi ◽  
H. Watanabe ◽  
T. Inakazu

In Japan most of the water distribution networks were constructed during the 1960s to 1970s. Since these pipelines were used for a long period, pipeline rehabilitation is necessary to maintain water supply. Although investment for pipeline rehabilitation has to be planned in terms of cost-effectiveness, no standard method has been established because pipelines were replaced on emergency and ad hoc basis in the past. In this paper, a method to determine the maintenance of the water supply on an optimal basis with a fixed budget for a water distribution network is proposed. Firstly, a method to quantify the benefits of pipeline rehabilitation is examined. Secondly, two models using Integer Programming and Monte Carlo simulation to maximize the benefits of pipeline rehabilitation with limited budget were considered, and they are applied to a model case and a case study. Based on these studies, it is concluded that the Monte Carlo simulation model to calculate the appropriate investment for the pipeline rehabilitation planning is both convenient and practical.


2011 ◽  
Vol 11 (4-5) ◽  
pp. 731-747 ◽  
Author(s):  
MASSIMILIANO CATTAFI ◽  
MARCO GAVANELLI ◽  
MADDALENA NONATO ◽  
STEFANO ALVISI ◽  
MARCO FRANCHINI

AbstractThis paper presents a new application of logic programming to a real-life problem in hydraulic engineering. The work is developed as a collaboration of computer scientists and hydraulic engineers, and applies Constraint Logic Programming to solve a hard combinatorial problem. This application deals with one aspect of the design of a water distribution network, i.e., the valve isolation system design. We take the formulation of the problem by Giustolisi and Savić (2008 Optimal design of isolation valve system for water distribution networks. InProceedings of the 10th Annual Water Distribution Systems Analysis Conference WDSA2008, J. Van Zyl, A. Ilemobade, and H. Jacobs, Eds.) and show how, thanks to constraint propagation, we can get better solutions than the best solution known in the literature for the Apulian distribution network. We believe that the area of the so-calledhydroinformaticscan benefit from the techniques developed in Constraint Logic Programming and possibly from other areas of logic programming, such as Answer Set Programming.


Author(s):  
Alex Takeo Yasumura Lima Silva ◽  
Fernando Das Graças Braga da Silva ◽  
André Carlos da Silva ◽  
José Antonio Tosta dos Reis ◽  
Claudio Lindemberg de Freitas ◽  
...  

 Inefficiency of sanitation companies’ operation procedures threatens the population’s future supplies. Thus, it is essential to increase water and energy efficiency in order to meet future demand. Optimization techniques are important tools for the analysis of complex problems, as in distribution networks for supply. Currently, genetic algorithms are recognized by their application in literature. In this regard, an optimization model of water distribution network is proposed, using genetic algorithms. The difference in this research is a methodology based on in-depth analysis of results, using statistics and the design of experimental tools and software. The proposed technique was applied to a theoretical network developed for the study. Preliminary simulations were accomplished using EPANET, representing the main causes of water and energy inefficiency in Brazilian sanitation companies. Some parameters were changed in applying this model, such as reservoir level, pipe diameter, pumping pressures, and valve-closing percentage. These values were established by the design of experimental techniques. As output, we obtained the equation of response surface, optimized, which resulted in values of established hydraulic parameters. From these data, the obtained parameters in computational optimization algorithms were applied, resulting in losses of 26.61%, improvement of 16.19 p.p. with regard to the network without optimization, establishing an operational strategy involving three pumps and a pressure-reducing valve.  We conclude that the association of optimization and the planning of experimental techniques constitutes an encouraging method to deal with the complexity of water-distribution network optimization.


Water distribution network (WDN) design of hydraulic model Gurthali, NARWANA-JIND, HARYANA and objective of this paper to detecting the leakage in it.In current research work to find out the Hl through normal valve and leak valve control setting with randomly value.To detect the Head Loss to usedDarcy Weisbach methodwhich calculate the major and minor loss with friction in pipes links. EPANET tool is used to create enlarge hydraulic model and simulate the data. All the pipes to be analysis unit head loss and nodes analysis head loss foe every houses. For leak detection, four normal valve include to compute head loss or pressure drop on nodes, pipes and leak detection valves. Also find out the pressure and head loss on the all nodes and pipes.MS Excel used for leak detection data, at the various head loss values in valves, nodes, pipes links. Plot the various graphs with head loss on valves which generated that HL reduces drastically


2020 ◽  
Vol 81 (8) ◽  
pp. 1606-1614 ◽  
Author(s):  
M. S. Nyirenda ◽  
T. T. Tanyimboh

Abstract The use of water quality indices to aggregate pollution loads in rivers has been widely studied, with researchers using various sub-indices and aggregation methods. These have been used to combine various quality variables at a sampling point in a river into an overall water quality index to compare the state of water quality in different river reaches. Service reservoirs in a water distribution network, like rivers, have complex mixing mechanisms, are subjected to various water quality variables and are variably sized and sited. Water quality indices and the relevant sub-indices are formulated here and applied to service reservoirs within a water distribution network. This is in an attempt to compare holistically the performance of service reservoirs in solutions of optimisation algorithms with regards to water quality.


2020 ◽  
Vol 12 (21) ◽  
pp. 9247
Author(s):  
Mingyuan Zhang ◽  
Juan Zhang ◽  
Gang Li ◽  
Yuan Zhao

Water distribution networks (WDNs), an interconnected collection of hydraulic control elements, are susceptible to a small disturbance that may induce unbalancing flows within a WDN and trigger large-scale losses and secondary failures. Identifying critical regions in a water distribution network (WDN) to formulate a scientific reinforcement strategy is significant for improving the resilience when network disruption occurs. This paper proposes a framework that identifies critical regions within WDNs, based on the three metrics that integrate the characteristics of WDNs with an external service function; the criticality of urban function zones, nodal supply water level and water shortage. Then, the identified critical regions are reinforced to minimize service loss due to disruptions. The framework was applied for a WDN in Dalian, China, as a case study. The results showed the framework efficiently identified critical regions required for effective WDN reinforcements. In addition, this study shows that the attributes of urban function zones play an important role in the distribution of water shortage and service loss of each region.


2013 ◽  
Vol 16 (3) ◽  
pp. 649-670 ◽  
Author(s):  
Myrna V. Casillas Ponce ◽  
Luis E. Garza Castañón ◽  
Vicenç Puig Cayuela

In this paper, we propose a new approach for model-based leak detection and location in water distribution networks (WDN), which considers an extended time-horizon analysis of pressure sensitivities. Five different ways of using the leak sensitivity matrix to isolate the leaks are described and compared. The first method is based on the binarization approach. The second, third and fourth methods are based on the comparison of the measured pressure vectors with the leak sensitivity matrix using different metrics: correlation, angle between vectors and Euclidean distance, respectively. The fifth method is based on the least square optimization method. The performance of these methods is compared when applied to two academic small networks (Hanoi and Quebra) widely used in the literature. Finally, the three methods with better performance are applied to a district metering area of the Barcelona WDN using real data.


2015 ◽  
Vol 2015 ◽  
pp. 1-16 ◽  
Author(s):  
Xudong Zhao ◽  
Zhilong Chen ◽  
Huadong Gong

Water distribution network (WDN) is critical to the city service, economic rehabilitation, public health, and safety. Reconstructing the WDN to improve its resilience in seismic disaster is an important and ongoing issue. Although a considerable body of research has examined the effects of different reconstruction strategies on seismic resistance, it is still hard for decision-makers to choose optimal resilience enhancing strategy. Taking the pipeline ductile retrofitting and network meshed expansion as demonstration, we proposed a feasible framework to contrast the resilience enhancing effects of two reconstruction strategies—units retrofitting strategy and network optimization strategy—in technical and organizational dimension. We also developed a new performance response function (PRF) which is based on network equilibrium theory to conduct the effects comparison in integrated technical and organizational dimension. Through the case study of municipal WDN in Lianyungang, China, the comparison results were thoroughly shown and the holistic decision-making support was provided.


2011 ◽  
Vol 243-249 ◽  
pp. 5003-5008
Author(s):  
Zhi Tao Wang ◽  
Jing Yu Su ◽  
Wei Wang

To evaluate the security of urban water distribution network, one model based on LS-SVM was put forth. On the basis of summary and analysis of influential factors for urban water distribution network security, a set of indexes used in the evaluation model above was constructed. The nonlinear mapping between the water distribution networks security classification and its conditions were learned from the finite samples and a water distribution network example was simulated using this model. In addition, the BP ANN model was used to simulate the same example. Through the analysis of the result of the actual security level, the security level acquired by the LS-SVM model and BP ANN model, it may be found that the result acquired by the LS-SVM model has high accuracy, and may used in actual engineering.