scholarly journals Experimental analysis of a novel helical air gap membrane distillation system

Author(s):  
Vandita T. Shahu ◽  
S. B. Thombre

Abstract Membrane distillation presents one of the feasible solutions to fresh water problems. The present study aims to develop an innovative Helical Air Gap Membrane Distillation (HAGMD) system and to analyze its behavior under different operating conditions. In this design the condenser is made up of a cylindrical copper tube with continuous helical fins over it, that increases the total available condensation area by almost 45% and enhances the overall heat transfer throughout the module. The presence of fins in the gap also reduces the total air gap width by almost 64%and therefore improves the flux production. A detailed experimental analysis is carried out for a better understanding of the underlying phenomenon. The effect of feed water temperature, feed flow rate, cold flow rate, coolant temperature and feed salinity on the performance of HAGMD is investigated experimentally. The analysis shows that the finned condenser results in very high flux. The maximum flux obtained from the system was 20 kg/m2 hr with feed of 5gm/liter salinity and a diving force temperature difference of 45 °C.

2020 ◽  
Vol 20 (5) ◽  
pp. 1678-1691 ◽  
Author(s):  
Mostafa Abd El-Rady Abu-Zeid ◽  
Gamal ElMasry

Abstract Two rectangular modules with a total interior membrane surface area of 13.53 m2 were consecutively combined to evaluate the use of heat recovery in an air-gap membrane distillation (AGMD) system. Several operating inlet parameters including feed water temperature, mass water flow rate and salinity were investigated. The experimental results revealed that the performance of the system was improved by virtue of efficient heat recovery resulting from combining two AGMD membrane modules in series. Under optimal inlet operating parameters of cooling water temperature of 20 °C, salinity of 0.05% and flow rate of 3 l/min, the system productivity (Pp) increased up to 192.9%, 179.3%, 176.5% and 179.2%, and the thermal efficiency (ηth) by 261.5%, 232.6%, 239.4% and 227.3% at feed water temperatures of 45 °C, 55 °C, 65 °C and 75 °C, respectively. Concurrently, the specific waste heat input (Ew.h.i) decreased by 6.7%, 4.7%, 5.6% and 2.7% due to the efficient heat recovery. The results confirmed that heat recovery is an important factor affecting the AGMD system that could be improved by designing one of the two AGMD modules with polytetrafluoroethylene (PTFE) hollow fibers with a flow length shorter than the other one having a salt rejection rate of 99%.


Author(s):  
Reza Baghaei Lakeh ◽  
Keaton Cornell ◽  
Benny Ly ◽  
Aaron Chan ◽  
Sepideh Jankhah

As the population grows, one issue that is continually being addressed is the lack of clean water resources. In order to explore viable solutions, rapid experimentation and research has been underway to alleviate the water crisis. With the addition of new emerging technology, the development, improvement, and understanding of various techniques used to treat non-potable water has expanded. One subcategory of water filtration in particular that has seen rapid growth is Membrane Distillation (MD). MD is a filtration process that utilizes thermal energy to desalinate and decontaminate water. Compared to current industry leading techniques such as reverse osmosis, MD does not require such large operating pressures, leading to less power consumption. MD is accomplished primarily by flowing contaminated feed water at elevated temperatures across semi-permeable membranes. The membranes used are made to allow water vapors to penetrate through and separate from the contaminated liquid portion. By maintaining a temperature difference across the membrane, a pressure gradient is created, which drives the vapor of feed water through the pores in the membrane. Once the vapor passes through the membrane, it condenses through various methods and is collected. Air Gap Membrane Distillation (AGMD) has shown significant ability to desalinate water effectively in small scales. The air gap between the membrane and condensation plate minimizes heat loss through conduction, making AGMD a more attractive option for upscaling. In this project a laboratory-scale test cell was developed to test AGMD using different membranes, and operational parameters. In order to test such parameters, a unique design with baffled channels to induce turbulence was designed and manufactured. Feed water and coolant temperature differences, flow rates, membrane porosity, and air gap thickness are among the parameters that has been studied in this research. Temperatures of the hot feed were varied from 40°C to 80°C while the cold feed temperature was kept at a near constant temperature of 0°C. Flow rates of feed water and coolant water range from 1 to 3 L/Min. It was observed that the permeate flux is an increasing function of feed water temperature and membrane porosity. The air gap thickness plays a major role in permeate flux and energy consumption of the system.


2020 ◽  
Vol 20 (7) ◽  
pp. 2884-2902
Author(s):  
Mostafa Abd El-Rady Abu-Zeid ◽  
Xiaolong Lu ◽  
Shaozhe Zhang

Abstract The negative effect of an air gap layer presented between the membrane and cooling plate on air gap membrane distillation (AGMD) performance was diminished largely by inserting a water gap membrane distillation (WGMD) module in series. The new design of air-gap–water-gap membrane distillation (AG-WG)MD was evaluated experimentally by comparing with an AGMD system under different operating conditions. In theory, mass and heat transfer in the new (AG-WG)MD and imitative AGMD systems were analyzed. Experimental outcomes showed that a new (AG-WG)MD design profoundly enhanced flux (Pd) and gained output ratio (GOR), and greatly decreased energy consumption (STEC) and heat input (EH.I). At a concentration of 5,000 mg/L, coolant temperature of 20 °C, and flow rate of 18 L/h, Pd was promoted by 76.26%, 40.84%, 35.45%, 30.91%, and GOR by 46.38%, 33.46%, 31.27%, 26.65%, in addition to STEC being reduced about 55.63%, 46.81%, 43.66%, 38.30%, and EH.I around 31.31%, 25.84%, 23.53%, 20.55%, from the AGMD to (AG-WG)MD system at feed temperatures of 50 °C, 60 °C, 70 °C, and 80 °C, respectively. The outcomes proved that the AGMD performance could be significantly promoted by integrating with WGMD in a combined MD system. This combination increased the temperature difference across the membrane and decreased thermal-concentration boundary layers for the AGMD system.


Author(s):  
Atia E. Khalifa ◽  
Dahiru U. Lawal ◽  
Mohamed A. Antar

Due to water scarcity in the Arabic gulf region, water desalination technologies are considered extremely important. The present work represents a fundamental study on the effect of basic operating and design variables on the flux of an air gap membrane distillation (AGMD) unit for water desalination. The flat sheet, channeled air gap membrane distillation module was designed and manufactured locally. The effect of feed flow rate, feed temperature, coolant water temperature, the air gap width, and the water salinity on the module flux are investigated. Analytical model for heat and mass transfer is used to predict the flux and the model results are compared to the experimental ones. Results showed that the technique has good potential to be used for water desalination. The permeate flux is increased by increasing feed flow rate, feed temperature, decreasing the air gap width, decreasing coolant temperature, and decreasing salinity of feed water. For a given feed flow rate, the width of the air gap and the feed water temperature are found to be the most effective parameters in increasing the distillate flux. Predicting the permeate flux with analytical models for heat and mass transfer showed good agreement with experimental results.


2019 ◽  
Vol 25 (11) ◽  
pp. 47-54
Author(s):  
Ahmed Shamil Khalaf ◽  
Asrar Abdullah Hassan

Membrane distillation (MD) is a hopeful desalination technique for brine (salty) water. In this research, Direct Contact Membrane Distillation (DCMD) and  Air Gap Membrane Distillation (AGMD) will be used. The sample used is from Shat Al –Arab water (TDS=2430 mg/l). A polyvinylidene fluoride (PVDF) flat sheet membrane was used as a flat sheet form with a plate and frame cell. Several parameters were studied, such as; operation time, feed temperature, permeate temperature, feed flow rate. The results showed that with time, the flux decreases because of the accumulated fouling and scaling on the membrane surface. Feed temperature and feed flow rate had a positive effect on the permeate flux, while permeate temperature had a reverse effect on permeate flux. It is noticeable that the flux in DCMD is greater than AGMD, at the same conditions. The flux in DCMD is 10.95LMH, and that in AGMD is 7.14 LMH.  In AGMD, the air gap layer made a high resistance. Here the temperature transport reduces in the permeate side of AGMD due to the air gap resistance. The heat needed for AGMD is lower than DCMD, this leads to low permeate flux because the temperature difference between the two sides is very small, so the driving force (vapor pressure) is low.                                                                                               


2019 ◽  
Vol 20 (1) ◽  
pp. 361-371 ◽  
Author(s):  
Vandita T. Shahu ◽  
S. B. Thombre

Abstract Membrane distillation is a rate-governed non-isothermal membrane separation technique that utilizes trans-membrane temperature difference for evaporating water and thereby separating it from brackish feed for reproducing fresh water. A novel design of a cylindrical air gap membrane distillation module is presented. The module is fabricated in a way similar to a shell and tube heat exchanger. A PTFE hydrophobic membrane is used and is formed in a cylindrical shape. Design of experiments (DOE) is used to design the experiments statistically and to identify the significant operating parameters. Experiments were performed according to the Taguchi design approach using an L16 orthogonal array. Optimization of the whole process is performed by response surface methodology. It is shown that the feed temperature and feed flow rate have a positive effect, whereas the salinity has a negative impact on flux. The maximum value of flux achieved with this system is 3.6 kg/m2 hr. A high value of flux of 2.6 kg/m2 hr was achieved under optimum conditions at a temperature of 45 °C and a flow rate of 1.5 lpm with a salinity of 5 g/litre.


2016 ◽  
Vol 11 (1) ◽  
pp. 41-45 ◽  
Author(s):  
Ehsan Karbasi ◽  
Javad Karimi-Sabet ◽  
J. Mohammadi Roshandeh ◽  
M. A. Moosavian ◽  
H. Ahadi

Abstract Some challenges, including inappropriate distribution of currents on the membrane surface, poor hydrodynamics and existing severe temperature polarization (TP) phenomenon in MD modules, impede industrialization of MD process. Computational fluid dynamics (CFD) method was used for numerical simulation of hydrodynamics in air gap membrane distillation modules. One of two simulated modules in this work is a novel developed one in which heat and mass transfer data was compared with available literature data. Moreover, the effect of using baffles in module was investigated. Comparison between the novel module and conventional module indicates higher trans-membrane mass flux and gained output ratio (GOR) coefficient by 7% and 15%, respectively. Moreover, the effects of different operating conditions including feed temperatures and feed flow rates on permeate flux were investigated.


2018 ◽  
Vol 13 (1) ◽  
pp. 200-209 ◽  
Author(s):  
Atia E. Khalifa

Abstract Membrane distillation (MD) is a promising thermally-driven membrane separation technology for water desalination. In MD, water vapor is being separated from the hot feed water solution using a micro-porous hydrophobic membrane, due to the difference in vapor pressures across the membrane. In the present work, experiments are conducted to compare the performance of water gap membrane distillation (WGMD) and air gap membrane distillation (AGMD) modules under the main operating and design conditions including the feed and coolant temperatures, membrane material and pore sizes, and the gap width. Results showed that the WGMD module produced higher fluxes as compared to the AGMD module, for all test conditions. The feed temperature is the dominant factor affecting the system flux. The permeate flux increases with reducing the gap width for both water and air gap modules. However, WGMD module was found to be less sensitive to the change in the gap width compared to the AGMD module. The PTFE membrane produced higher permeate flux as compared to the PVDF membrane. Bigger mean pore diameter enhanced the permeate flux, however, this enhancement is marginal at high feed temperatures. With increasing the feed temperature, the GOR values increase and the specific energy consumption decreases.


2021 ◽  
Vol 945 (1) ◽  
pp. 012026
Author(s):  
Rubina Bahar ◽  
Mohammad Jabed Perves Bappy

Abstract The membrane distillation (MD) process is an evaporative metho driven by the partial pressure difference between two different temperature solutions, namely the hot feed and the coolant. The hot feed evaporates, and the vapour gets condensed to the cooler side. A hydrophobic membrane maintains the evaporating surface. Air Gap Membrane Distillation(AGMD) separates the hot feed from the coolant by a narrow air gap and a coolant plate. The condensate forms on the coolant plate, and the air gap works as an insulation for the heat loss through the membrane. The salient parameters like feed temperature, coolant temperature, and air gap thickness have already been identified through research in previous years. In this study, an innovative technique has been tested to minimize the polarization and increase the production from an AGMD lab-scale unit. The effect of the feed flow entry angle has been investigated. Also, the combined effect of inclined flow entry and a finned coolant surface has been studied. It has been found from the experiments that with a feed flow entry angle of 60°, the system shows an average of 10% to 14% boost in performance. When 60° inlet flow angle and finned coolant plate work in combination, an average of 69% to 78% increase of distillate flux was observed with the same energy input.


2014 ◽  
Vol 69 (9) ◽  
Author(s):  
Rubina Bahar ◽  
M. N. A. Hawlader ◽  
K. C. Ng ◽  
Yee Jiun Haw

Membrane distillation (MD) is a separation process that involves vapour transport through a hydrophobic membrane. The evaporation is caused by the partial pressure difference between a hot fluid and cold fluid/surface. In this study, an air gap MD (AGMD) process is utilized to produce freshwater from saline solution. A multi-stage AGMD unit with 0.45 mm pore size Polyvinylidene Fluoride (PVDF) membranes is built and experiments have been carried out with different operating variables including feed temperature, coolant temperature, air gap width and feed inlet concentration.A maximum of 12.9 kg/m2 of distillate flux was obtained per kWh energy input from the multi-stage MD unit while for a previously built single-stage MD unit, the highest water/power ratio obtained was only 2.3 kg /m2 kWh. This variation indicates that multistaging is necessary for efficeint energy use in MD system. 


Sign in / Sign up

Export Citation Format

Share Document