Modeling of a large-scale wastewater treatment plant for efficient operation

2004 ◽  
Vol 50 (7) ◽  
pp. 123-130 ◽  
Author(s):  
C.F. Gokcay ◽  
G. Sin

Environmental legislations in the Western world impose stringent effluent quality standards for ultimate protection of the environment. This is also observed in Turkey. The current paper presents efforts made to simulate an existing 0.77 million m3/day conventional activated sludge plant located at Ankara, AWTP. The ASM1 model was used for simulation in this study. The model contains numerous stoichiometric and kinetic parameters, some of which need to be determined on case by case bases. The easily degradable COD (SS) was determined by two methods, physical-chemical and respirometric methods, namely. The latter method was deemed unreliable and rejected in the further study. Dynamic simulation with SSSP program predicted effluent COD and MLSS values successfully while overestimating OUR. A complete fit could only be obtained by introducing a dimensionless correction factor (ηO2 = 0.58) to the oxygen term in ASM1.

Author(s):  
Badrus Zaman ◽  
Wiharyanto Oktiawan

Most community settlements in Indonesia do not have a household scale of a wastewater treatment plant. Fatal impacts on the environment and human health can occur at any time, including (a) causing environmental damage (disaster), (b) damaging beauty/aesthetics for the scenery will be unpleasant and foul-smelling, (c) polluting water bodies, and (d ) endangering health. The purpose of this study is to optimize the Multi Soil Layering (MSL) System to treat domestic wastewater (greywater) using environmentally friendly materials that are available in Indonesia. The research method used the MSL system with the first variation using a batch system with Hydraulic retention time (HRT) for 24 hours and the second variation using an intermittent system with 3, 6, 9 hours HRT. The results showed that the MSL system was able to eliminate COD well. The highest COD removal efficiency was 93.44% at 9 hours HRT, but the effluent quality did not meet the required quality standards. The development of MSL systems that produces an effluent quality that meets the quality standards needs to be studied further.


2016 ◽  
Vol 73 (12) ◽  
pp. 3049-3056 ◽  
Author(s):  
N. Paxéus ◽  
K. Bester ◽  
Haitham El-taliawy

Abstract Loads of individual commonly used analgesics (ibuprofen, diclofenac), antibiotics (sulfamethoxazole, trimethoprim), β-blockers (atenolol, metoprolol, sotalol, propranolol) and neuroleptics (carbamazepine, citalopram) to a large-scale operating wastewater treatment plant (WWTP) in Sweden (Ryaverket) were studied by monitoring concentrations and flows during a 9-year period (2006–2015). Variations in loads due to sampling and possible errors in chemical analyses were estimated to be below 40%. The variations in loads were analyzed and discussed in terms of the design of collecting wastewater system as an integrated part of the water treatment at the WWTP as well as the prescription and use of individual pharmaceuticals. Trend analysis in daily loads of individual pharmaceuticals indicated an increase for diclofenac, no significant changes for ibuprofen and metoprolol and a decrease for the other pharmaceuticals. The latter was ascribed to a decrease in their prescription and use. The increase in loads of diclofenac was ascribed to its growing topical use not requiring prescription. In view of future regulations by the EU, growing loads of diclofenac to WWTPs and its low removal rates in WWTPs may require an upgrade of WWTPs to achieve quality standards for diclofenac in receiving waters.


Author(s):  
Maria Clara V. M. Starling ◽  
Elizângela P. Costa ◽  
Felipe A. Souza ◽  
Elayne C. Machado ◽  
Juliana Calábria de Araujo ◽  
...  

AbstractThis work investigated an innovative alternative to improve municipal wastewater treatment plant effluent (MWWTP effluent) quality aiming at the removal of contaminants of emerging concern (caffeine, carbendazim, and losartan potassium), and antibiotic-resistant bacteria (ARB), as well as disinfection (E. coli). Persulfate was used as an alternative oxidant in the solar photo-Fenton process (solar/Fe/S2O82−) due to its greater stability in the presence of matrix components. The efficiency of solar/Fe/S2O82− at neutral pH using intermittent iron additions is unprecedented in the literature. At first, solar/Fe/S2O82− was performed in a solar simulator (30 W m−2) leading to more than 60% removal of CECs, and the intermittent iron addition strategy was proved effective. Then, solar/Fe/S2O82− and solar/Fe/H2O2 were compared in semi-pilot scale in a raceway pond reactor (RPR) and a cost analysis was performed. Solar/Fe/S2O82− showed higher efficiencies of removal of target CECs (55%), E. coli (3 log units), and ARB (3 to 4 log units) within 1.9 kJ L−1 of accumulated irradiation compared to solar/Fe/H2O2 (CECs, 49%; E. coli, 2 log units; ARB, 1 to 3 log units in 2.5 kJ L−1). None of the treatments generated acute toxicity upon Allivibrio fischeri. Lower total cost was obtained using S2O82− (0.6 € m−3) compared to H2O2 (1.2 € m−3). Therefore, the iron intermittent addition aligned to the use of persulfate is suitable for MWWTP effluent quality improvement at neutral pH.


2012 ◽  
Vol 65 (4) ◽  
pp. 589-595 ◽  
Author(s):  
A. Ouali ◽  
H. Jupsin ◽  
J. L. Vasel ◽  
L. Marouani ◽  
A. Ghrabi

Korba wastewater treatment plant is a conventional activated sludge followed by three maturation ponds (MP1, MP2, MP3) in series acting as a tertiary treatment. The first study of wastewater treatment plants showed that the effluent concentration of Escherichia coli and enterococci at the outlet of the (MP3) varies between 103 and 104CFU/100 ml. After the hydrodynamic study conducted by Rhodamine WT which showed short-circuiting in the MP1, two baffles were introduced in the first maturation pond (MP1) to improve the hydrodynamic and the sanitary performances. The second hydraulic study showed that the dispersion number ‘d’ was reduced from 1.45 to 0.43 by this engineering intervention and the Peclet number was raised from 0.69 to 2.32. The hydraulic retention time was increased by 14 h. Because of well-designed baffles, the removal efficiency of E. coli and enterococci was raised between 0.2 and 0.7 log units for the first maturation pond.


2017 ◽  
Vol 77 (2) ◽  
pp. 337-345 ◽  
Author(s):  
I. Brückner ◽  
K. Kirchner ◽  
Y. Müller ◽  
S. Schiwy ◽  
K. Klaer ◽  
...  

Abstract The project DemO3AC (demonstration of large-scale wastewater ozonation at the Aachen-Soers wastewater treatment plant, Germany) of the Eifel-Rur Waterboard contains the construction of a large-scale ozonation plant for advanced treatment of the entire 25 million m³/yr of wastewater passing through its largest wastewater treatment plant (WWTP). In dry periods, up to 70% of the receiving water consists of treated wastewater. Thus, it is expected that effects of ozonation on downstream water biocoenosis will become observable. Extensive monitoring of receiving water and the WWTP shows a severe pollution with micropollutants (already prior to WWTP inlet). (Eco-)Toxicological investigations showed increased toxicity at the inlet of the WWTP for all assays. However, endocrine-disrupting potential was also present at other sampling points at the WWTP and in the river and could not be eliminated sufficiently by the WWTP. Total cell counts at the WWTP are slightly below average. Investigations of antibiotic resistances show no increase after the WWTP outlet in the river. However, cells carrying antibiotic-resistant genes seem to be more stress resistant in general. Comparing investigations after implementation of ozonation should lead to an approximation of the correlation between micropollutants and water quality/biocoenosis and the effects that ozonation has on this matter.


2013 ◽  
Vol 68 (2) ◽  
pp. 433-440 ◽  
Author(s):  
Wanhui Zhang ◽  
Chaohai Wei ◽  
Chunhua Feng ◽  
Yuan Ren ◽  
Yun Hu ◽  
...  

The occurrence of 14 phenolic compounds (PCs) was assessed in the raw, treated wastewater, dewatered sludge and gas samples from a coking wastewater treatment plant (WWTP) in China. It was found that 3-cresol was the dominant compound in the raw coking wastewater with a concentration of 183 mg L−1, and that chlorophenols and nitrophenols were in the level of μg L−1. Phenol was the dominant compound in the gas samples, while 2,4,6-trichlorophenol predominated in the dewatered sludge sample. The anaerobic and aerobic tanks played key roles in the elimination of chlorophenols and phenols, respectively. Analysis of daily mass flows of PCs in WWTP showed that 89–98% of phenols and 83–89% of nitrophenols were biodegraded, and that 44–69% of chlorophenols were adsorbed to sludge, indicating that the fate of PCs was highly influenced by their biodegradability and physical–chemical property.


2012 ◽  
Vol 573-574 ◽  
pp. 659-662
Author(s):  
Hao Wang

In Tangshan area, the secondary effluent of wastewater treatment plants was used for this study. Horizontal zeolite wetland was carried out treating it. Hydraulic loading rate was the parameters for analyzing the nitrogen and phosphorus removal efficiency of pollutants from the secondary effluent of wastewater treatment plant. Zeolite constructed wetlands showed different behaviors for nitrogen and phosphorus removals.Under the optimum hydraulic loading rate, the primary pollutions were removed to a large extent.


Author(s):  
В.А. Кондрашев ◽  
С.Г. Метелица

Рассмотрены вопросы, связанные с проведением пусконаладочных работ биоблока станции очистки хозяйственно-бытовых и близких к ним по составу сточных вод при пробном пуске в эксплуатацию очистных сооружений. Подробно рассмотрены этапы пусконаладочных работ биоблока очистных сооружений с «затравкой» активным илом из действующих биологических очистных сооружений и с дозировкой легкоокисляемой органики. Описан состав оборудования станции КОС-9 производства «Гермес Групп». Рассмотрены все этапы пусконаладочных работ биоблока на примере запуска очистных сооружений КОС-9 с привлечением многочисленных опытных данных. Определены периоды этапов пусконаладки биоблока. Приведены проблемы наладки биоблока и пути их решения с достижением требуемого результата. Технология, используемая на станции, обеспечивает очистку сточных вод, соответствующую требованиям, предъявляемым к выпуску очищенных стоков в водоем рыбохозяйственного значения. Issues related to commissioning a biological treatment plant at the facilities for household and similar in composition wastewater treatment during the trial start of the treatment facilities are considered. The stages of commissioning a biological treatment plant at the wastewater treatment facilities with «inoculating» activated sludge from the operating biological treatment facilities and with dosing easily oxidable organic matter are considered in detail. The equipment configuration of the WWTP-9 produced by Germes Group is described. All stages of the biological treatment plant commissioning are considered through the example of the start-up of WWTP-9 with the use of numerous experimental data. The periods of biological treatment plant commissioning stages have been determined. The problems of adjusting the biological treatment plant and the ways of their elimination to achieve the required result are presented. The technology used at the WWT facilities provides for the effluent quality that meets the requirements for the discharge into a water body of commercial fishing importance.


Sign in / Sign up

Export Citation Format

Share Document