scholarly journals Efficiency of an up-flow Anaerobic Sludge Blanket reactor coupled with an electrochemical system to remove chloramphenicol in swine wastewater

Author(s):  
Itzel Romero-Soto ◽  
Celestino Garcia-Gomez ◽  
Luis Leyva-Soto ◽  
Juan Napoles-Armenta ◽  
María Concha-Guzman ◽  
...  

Abstract The application and design of treatment systems in wastewater are necessary due to antibiotics' potential toxicity and resistant genes on residual effluent. This work evaluated a coupled bio-electrochemical system to reduce chloramphenicol (CAP) and chemical oxygen demand (COD) on swine wastewater (SWW). SWW characterization found CAP of <10 μg/L and 17,434 mg/L of COD. The coupled system consisted of preliminary use of an Up-flow Anaerobic Sludge Blanket Reactor (UASB) followed by electrooxidation (EO). UASB reactor (primary stage) was operated for three months at an organic load of 8.76 kg of COD/m3d and 50 mg CAP/L as initial concentration. In EO, we carried out a 22 (time operation and intensity) factorial design with a central composite design; we tried two Ti cathodes and one anode of Ti/PbO2. Optimal conditions obtained in the EO process were 240 min of operation time and 1.51 A of current intensity. It was possible to eliminate 44% of COD and 64.2% of CAP in the preliminary stage. On bio-electrochemical, a total COD and CAP removal were 82.35% and >99.99%, respectively. This coupled system can be applied to eliminate antibiotics and other organic pollutants in agricultural, industrial, municipal, and other wastewaters.

2017 ◽  
Vol 38 (6) ◽  
pp. 3705
Author(s):  
Luciano Dos Santos Rodrigues ◽  
Ana Cristina Araujo Pinto ◽  
Joyce Da Cruz Ferraz Dutra ◽  
Renata Rodrigues Sampaio ◽  
Stella Rubim de Sousa ◽  
...  

The purpose of this study was to assess the swine wastewater treatment system, consisting of the anaerobic baffled reactor (ABR), followed by the upflow anaerobic sludge blanket (UASB) reactor at full scale. The system was monitored by analyzing samples collected in the influent and effluent of ABR and UASB. The following parameters were analyzed: temperature, pH, total suspended solids (TSS), volatile suspended solids (VSS), biochemical oxygen demand (BOD), and chemical oxygen demand (COD). Averages of total removal of COD and BOD were 96.7 and 98.4%, respectively. The mean concentrations of COD, BOD, TSS, and VSS at the final effluent were 611, 124, 138, and 134 mg L-1, respectively. The mean volumetric organic loadings (VOL) at the ABR and UASB were 10.29 and 0.99 kg COD m-1d-1. Therefore, the ABR-UASB system was found to be a promising alternative for the swine wastewater treatment.


2021 ◽  
Author(s):  
Perla Gonzalez ◽  
Ana Aguilar Ruiz ◽  
Andrea Reynosa Varela ◽  
Ulises Durán Hinojosa ◽  
Marco Garzón Zuñiga ◽  
...  

Abstract This study focused on evaluating different support media for COD and nitrogen compound removal from an Upflow Anaerobic Sludge Blanket (UASB) reactor fed with swine wastewater. Maximum specific nitrification (MSNA) and denitrification (MSDA) activity tests were performed in two fixed-film systems with (1) polyurethane foam (R1) and (2) polyethylene rings (R2). The results showed that the R2 system performed more efficiently than R1, reaching organic matter removal of 77 ± 8% and nitrogen of 98 ± 4%, attributed to higher specific denitrifying activity recorded (5.3 ± 0.34 g NO3--N/g VTS ∙h). In this sense, MSDA tests indicated that the suspended biomass was responsible for at least 70% of nitrogen removal in the form of ammonium compared with 20% attributed to biomass in the form of biofilm. On the other hand, 40 ± 5% of initial nitrogen could not be quantified in the system effluents, but 10 ± 1% was attributed to loss by volatilization. According to the analyses, the previous information infers the development of simultaneous nitrification-denitrification (SND) routes. Respect to the analyses of microbial diversity and abundance in the biofilm of R2 rings, the presence of the genus Pseudomonas dominated the prokaryotic community of the system in 54.4%.


2012 ◽  
Vol 9 ◽  
pp. 57-62
Author(s):  
Fiza Sarwar ◽  
Wajeeha Malik ◽  
Muhammad Salman Ahmed ◽  
Harja Shahid

Abstract: This study was designed using actual effluent from the sugary mills in an Up-flow Anaerobic Sludge Blanket (UASB) Reactor to evaluate treatability performance. The reactor was started-up in step-wise loading rates beginning from 0.05kg carbon oxygen demand (COD)/m3-day to 3.50kg-COD/m3-day. The hydraulic retention time (HRT) was slowly decreased from 96 hrs to eight hrs. It was observed that the removal efficiency of COD of more than 73% can be easily achieved at an HRT of more than 16 hours corresponding to an average organic loading rate (OLR) of 3.0kg-COD/m3-day, at neutral pH and constant temperature of 29°C. The average VFAs (volatile fatty acids) and biogas production was observed as 560mg/L and 1.6L/g-CODrem-d, respectively. The average methane composition was estimated as 62%. The results of this study suggest that the treatment of sugar mills effluent with the anaerobic technology seems to be more reliable, effective and economical.DOI: http://dx.doi.org/10.3126/hn.v9i0.7075 Hydro Nepal Vol.9 July 2011 57-62


2020 ◽  
Vol 81 (9) ◽  
pp. 1951-1960 ◽  
Author(s):  
C. S. Cabral ◽  
A. L. Sanson ◽  
R. J. C. F. Afonso ◽  
C. A. L. Chernicharo ◽  
J. C. Araújo

Abstract Two bioreactors were investigated as an alternative for the post-treatment of effluent from an upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage, aiming at dissolved sulfide and methane removal. The bioreactors (R-control and R-air) were operated at different hydraulic retention times (HRT; 6 and 3 h) with or without aeration. Large sulfide and methane removal efficiencies were achieved by the microaerated reactor at HRT of 6 h. At this HRT, sulfide removal efficiencies were equal to 61% and 79%, and methane removal efficiencies were 31% and 55% for R-control and R-air, respectively. At an HRT of 3 h, sulfide removal efficiencies were 22% (R-control) and 33% (R-air) and methane removal did not occur. The complete oxidation of sulfide, with sulfate formation, prevailed in both phases and bioreactors. However, elemental sulfur formation was more predominant at an HRT of 6 h than at an HRT of 3 h. Taken together, the results show that post-treatment improved the anaerobic effluent quality in terms of chemical oxygen demand and solids removal. However, ammoniacal nitrogen was not removed due to either the low concentration of air provided or the absence of microorganisms involved in the nitrogen cycle.


2012 ◽  
Vol 65 (10) ◽  
pp. 1887-1894 ◽  
Author(s):  
V. Singh ◽  
A. K. Mittal

This study reports applicability of upflow anaerobic sludge blanket (UASB) process to treat the leachate from a municipal landfill located in Delhi. A laboratory scale reactor was operated at an organic loading rate of 3.00 kg chemical oxygen demand (COD)/m3 d corresponding to a hydraulic retention time (HRT) of 12 h for over 8 months. The effect of toxicity of leachate, and feed composition on the treatability of leachate was evaluated. Average COD of the leachate, during the study period varied between 8,880 and 66,420 mg/l. Toxicity of the leachate used during a period of 8 months varied from LC50 1.22 to 12.35 for 96 h. The removal efficiency of soluble COD ranged between 91 and 67% for fresh leachate and decreased drastically from 90 to 35% for old leachate having high toxicity. The efficiency varied from 81 to 65%. The reactor performed more efficiently for the treatment of fresh leachate (less toxic, LC50 11.64, 12.35, and 12.15 for 96 h) as compared with old leachate (more toxic, LC50 1.22 for 96 h). Toxicity of the leachate affected its treatment potential by the UASB.


2004 ◽  
Vol 31 (3) ◽  
pp. 420-431 ◽  
Author(s):  
S K Patidar ◽  
Vinod Tare

The effect of micro-nutrients, such as Fe, Ni, Zn, Co, and Mo, on anaerobic degradation of sulfate laden organics was investigated using bench-scale models of upflow anaerobic sludge blanket (UASB) reactor, anaerobic baffled reactor (ABR), and hybrid anaerobic baffled reactor (HABR), operating in varying conditions in ten phases (organic loading of 1.9–5.75 kg COD/(m3·d), sulfate loading of 0.54–1.88 kg SO42–/(m3·d), chemical oxygen demand (COD):SO42–ratio of 2.0–8.6). In the initial phase, no nutrient limitation was observed with COD removal of more than 94% in all three systems. Subsequently, increase in sulfate loading resulted in Ni and Co limitation and their supplementation restored COD removal in UASB system. However, baffled systems did not recover because of severe inhibition by sulfide. Results indicate that precipitation of nutrients could seriously deteriorate process performance, leading to failure even before sulfide concentration attains toxic level. The limitation of Fe coupled with high sulfate loading (1.88 kg SO42–/(m3·d)) resulted in growth of low-density, fragile, hollow, and granular biomass in UASB that washed out and caused process instability. Supplementation of Fe with other nutrients stabilized UASB process and also improved COD removal.Key words: anaerobic degradation, nutrients, UASB, ABR, HABR, sulfide toxicity, sulfate laden organics.


2013 ◽  
Vol 67 (1) ◽  
pp. 24-32 ◽  
Author(s):  
Tarek Elmitwalli

Although the upflow anaerobic sludge blanket (UASB) reactor has been widely applied for domestic wastewater treatment in many developing countries, there is no sufficient mathematical model for proper design and operation of the reactor. An empirical model based on non-linear regression was developed to represent the physical and chemical removal of suspended solids (SS) in the reactor. Moreover, a simplified dynamic model based on ADM1 and the empirical model for SS removal was developed for anaerobic digestion of the entrapped SS and dissolved matter in the wastewater. The empirical model showed that effluent suspended chemical oxygen demand (CODss) concentration is directly proportional to the influent CODss concentration and inversely proportional to both the hydraulic retention time (HRT) of the reactor and wastewater temperature. For obtaining sufficient CODss removal, the HRT of the UASB reactor must be higher than 4 h, and higher HRT than 12 h slightly improved CODss removal. The dynamic model results showed that the required time for filling the reactor with sludge mainly depends on influent total chemical oxygen demand (CODt) concentration and HRT. The influent CODt concentration, HRT and temperature play a crucial role on the performance of the reactor. The results indicated that shorter HRT is needed for optimization of CODt removal, as compared with optimization of CODt conversion to methane. Based on the model results, the design HRT of the UASB reactor should be selected based on the optimization of wastewater conversion and minimization of biodegradable SS accumulation in the sludge bed, not only based on COD removal, to guarantee a stable reactor performance.


2015 ◽  
Vol 72 (11) ◽  
pp. 2034-2044 ◽  
Author(s):  
Rosa Elena Yaya Beas ◽  
Katarzyna Kujawa-Roeleveld ◽  
Jules B. van Lier ◽  
Grietje Zeeman

This research was conducted to study the faecal coliforms removal capacity of downflow hanging sponge (DHS) reactors as a post-treatment for an upflow anaerobic sludge blanket (UASB) reactor. Three long-term continuous laboratory-scale DHS reactors, i.e. a reactor with cube type sponges without recirculation, a similar one with recirculation and a reactor with curtain type sponges, were studied. The porosities of the applied medium were 91%, 87% and 47% respectively. The organic loading rates were 0.86 kgCOD m−3 d−1, 0.53 kgCOD m−3 d−1 and 0.24 kgCOD m−3 d−1 correspondingly at hydraulic loading rates of 1.92 m3 m−2 d−1, 2.97 m3 m−2 d−1 and 1.32 m3 m−2 d−1, respectively (COD: chemical oxygen demand). The corresponding averages for faecal coliform removal were 99.997%, 99.919% and 92.121% respectively. The 1989 WHO guidelines standards, in terms of faecal coliform content for unrestricted irrigation (category A), was achieved with the effluent of the cube type DHS (G1) without recirculation. Restricted irrigation, category B and C, is assigned to the effluent of the cube type with recirculation and the curtain type, respectively. Particularly for organic compounds, the effluent of evaluated DHS reactors complies with USEPA standards for irrigation of so called non-food crops like pasture for milking animals, fodder, fibre, and seed crops.


2011 ◽  
Vol 63 (5) ◽  
pp. 877-884 ◽  
Author(s):  
P. Mijalova Nacheva ◽  
M. Reyes Pantoja ◽  
E. A. Lomelí Serrano

The performance of an upflow anaerobic sludge blanket (UASB) reactor operated at ambient temperature (20.9–25.2°C) was analysed for the treatment of slaughterhouse wastewater previously pre-treated for solid separation. The experimental work was carried out in a reactor with 15 L effective volume. Four organic loads were applied and the process performance was evaluated. The COD removal rate increased with the load rise from 4 to 15 kg COD.m−3.d−1. Removal efficiencies of 90% were obtained with a load of 15 kg COD.m−3.d−1. The entrapment of suspended solids in the sludge blanket was greater in proportion during the first two stages due to the low upflow velocities used when loads of 4 and 7 kg COD.m−3.d−1 were evaluated. This phenomenon did not affect the structure of the biological grains or their methanogenic activity. More than 50% of the organic nitrogen was degraded, causing a 3% increase of ammonia concentration. The concentrations of the volatile fatty acids were not high and the wastewater alkalinity was enough to prevent acidification. The yield coefficient of methane production increased with the load rise, reaching 0.266 m3/kg CODremoved at 15 kg COD.m−3.d−1 organic load. The UASB reactor is a good option for the biological treatment of pre-treated slaughterhouse wastewater. However, additional treatment is required in order to accomplish the water quality requirements in discharges to water bodies.


2019 ◽  
Vol 80 (8) ◽  
pp. 1505-1511 ◽  
Author(s):  
Nathalie Dyane Miranda Slompo ◽  
Larissa Quartaroli ◽  
Grietje Zeeman ◽  
Gustavo Henrique Ribeiro da Silva ◽  
Luiz Antonio Daniel

Abstract Decentralized sanitary wastewater treatment has become a viable and sustainable alternative, especially for developing countries and small communities. Besides, effluents may present variations in chemical oxygen demand (COD), biochemical oxygen demand (BOD) and total nitrogen values. This study describes the feasibility of using a pilot upflow anaerobic sludge blanket (UASB) reactor to treat wastewater with different organic loads (COD), using black water (BW) and sanitary wastewater, in addition to its potential for preserving nutrients for later recovery and/or reuse. The UASB reactor was operated continuously for 95 weeks, with a hydraulic retention time of 3 days. In Phase 1, the reactor treated simulated BW and achieved 77% CODtotal removal. In Phase 2, treating only sanitary wastewater, the CODtotal removal efficiency was 60%. Phase 3 treated simulated BW again, and CODtotal removal efficiency was somewhat higher than in Phase 1, reaching 81%. In Phase 3, the removal of pathogens was also evaluated: the efficiency was 1.96 log for Escherichia coli and 2.13 log for total coliforms. The UASB reactor was able to withstand large variations in the organic loading rate (0.09–1.49 kg COD m−3 d−1), in continuous operation mode, maintaining a stable organic matter removal.


Sign in / Sign up

Export Citation Format

Share Document