scholarly journals Effects of Head Models and Dipole Source Parameters on EEG Fields

2015 ◽  
Vol 9 (1) ◽  
pp. 10-16 ◽  
Author(s):  
Li Peng ◽  
Mingming Peng ◽  
Anhuai Xu

Head model and an efficient method for computing the forward EEG (electroencephalography)problem are essential to dipole source localization(DSL). In this paper, we use less expensive ovoid geometry to approximate human head, aiming at investigating the effects of head shape and dipole source parameters on EEG fields. The application of point least squares (PLS) based on meshless method was introduced for solving EEG forward problem and numerical simulation is implemented in three kinds of ovoid head models. We present the performances of the surface potential in the face of varying dipole source parameters in detail. The results show that the potential patterns are similar for different dipole position in different head shapes, but the peak value of potential is significantly influenced by the head shape. Dipole position induces a great effect on the peak value of potential and shift of peak potential. The degree of variation between sphere head model and non-sphere head models is seen at the same time. We also show that PLS method with the trigonometric basis is superior to the constant basis, linear basis, and quadratic basis functions in accuracy and efficiency.

2015 ◽  
Vol 08 (03) ◽  
pp. 1540003 ◽  
Author(s):  
Yan Ye ◽  
Xiaoping Li ◽  
Tiecheng Wu ◽  
Zhe Li ◽  
Wenwen Xie

Deep brain activity is conventionally recorded with surgical implantation of electrodes. During the neurosurgery, brain tissue damage and the consequent side effects to patients are inevitably incurred. In order to eliminate undesired risks, we propose that deep brain activity should be measured using the noninvasive scalp electroencephalography (EEG) technique. However, the deeper the neuronal activity is located, the noisier the corresponding scalp EEG signals are. Thus, the present study aims to evaluate whether deep brain activity could be observed from EEG recordings. In the experiment, a three-layer cylindrical head model was constructed to mimic a human head. A single dipole source (sine wave, 10 Hz, altering amplitudes) was embedded inside the model to simulate neuronal activity. When the dipole source was activated, surface potential was measured via electrodes attached on the top surface of the model and raw data were recorded for signal analysis. Results show that the dipole source activity positioned at 66 mm depth in the model, equivalent to the depth of deep brain structures, is clearly observed from surface potential recordings. Therefore, it is highly possible that deep brain activity could be observed from EEG recordings and deep brain activity could be measured using the noninvasive scalp EEG technique.


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Alireza Chamanzar ◽  
Marlene Behrmann ◽  
Pulkit Grover

AbstractA rapid and cost-effective noninvasive tool to detect and characterize neural silences can be of important benefit in diagnosing and treating many disorders. We propose an algorithm, SilenceMap, for uncovering the absence of electrophysiological signals, or neural silences, using noninvasive scalp electroencephalography (EEG) signals. By accounting for the contributions of different sources to the power of the recorded signals, and using a hemispheric baseline approach and a convex spectral clustering framework, SilenceMap permits rapid detection and localization of regions of silence in the brain using a relatively small amount of EEG data. SilenceMap substantially outperformed existing source localization algorithms in estimating the center-of-mass of the silence for three pediatric cortical resection patients, using fewer than 3 minutes of EEG recordings (13, 2, and 11mm vs. 25, 62, and 53 mm), as well for 100 different simulated regions of silence based on a real human head model (12 ± 0.7 mm vs. 54 ± 2.2 mm). SilenceMap paves the way towards accessible early diagnosis and continuous monitoring of altered physiological properties of human cortical function.


PeerJ ◽  
2017 ◽  
Vol 5 ◽  
pp. e4061 ◽  
Author(s):  
Awais Munawar Qureshi ◽  
Zartasha Mustansar

In this paper, we have presented a microwave scattering analysis from multiple human head models. This study incorporates different levels of detail in the human head models and its effect on microwave scattering phenomenon. Two levels of detail are taken into account; (i) Simplified ellipse shaped head model (ii) Anatomically realistic head model, implemented using 2-D geometry. In addition, heterogenic and frequency-dispersive behavior of the brain tissues has also been incorporated in our head models. It is identified during this study that the microwave scattering phenomenon changes significantly once the complexity of head model is increased by incorporating more details using magnetic resonance imaging database. It is also found out that the microwave scattering results match in both types of head model (i.e., geometrically simple and anatomically realistic), once the measurements are made in the structurally simplified regions. However, the results diverge considerably in the complex areas of brain due to the arbitrary shape interface of tissue layers in the anatomically realistic head model.After incorporating various levels of detail, the solution of subject microwave scattering problem and the measurement of transmitted and backscattered signals were obtained using finite element method. Mesh convergence analysis was also performed to achieve error free results with a minimum number of mesh elements and a lesser degree of freedom in the fast computational time. The results were promising and the E-Field values converged for both simple and complex geometrical models. However, the E-Field difference between both types of head model at the same reference point differentiated a lot in terms of magnitude. At complex location, a high difference value of 0.04236 V/m was measured compared to the simple location, where it turned out to be 0.00197 V/m. This study also contributes to provide a comparison analysis between the direct and iterative solvers so as to find out the solution of subject microwave scattering problem in a minimum computational time along with memory resources requirement.It is seen from this study that the microwave imaging may effectively be utilized for the detection, localization and differentiation of different types of brain stroke. The simulation results verified that the microwave imaging can be efficiently exploited to study the significant contrast between electric field values of the normal and abnormal brain tissues for the investigation of brain anomalies. In the end, a specific absorption rate analysis was carried out to compare the ionizing effects of microwave signals to different types of head model using a factor of safety for brain tissues. It is also suggested after careful study of various inversion methods in practice for microwave head imaging, that the contrast source inversion method may be more suitable and computationally efficient for such problems.


2021 ◽  
Vol 36 (2) ◽  
pp. 159-167
Author(s):  
Fatih Kaburcuk ◽  
Atef Elsherbeni

Numerical study of electromagnetic interaction between an adjacent antenna and a human head model requires long computation time and large computer memory. In this paper, two speeding up techniques for a dispersive algorithm based on finite-difference time-domain method are used to reduce the required computation time and computer memory. In order to evaluate the validity of these two speeding up techniques, specific absorption rate (SAR) and temperature rise distributions in a dispersive human head model due to radiation from an antenna integrated into a pair of smart glasses are investigated. The antenna integrated into the pair of smart glasses have wireless connectivity at 2.4 GHz and 5th generation (5G) cellular connectivity at 4.9 GHz. Two different positions for the antenna integrated into the frame are considered in this investigation. These techniques provide remarkable reduction in computation time and computer memory.


Author(s):  
X. Gary Tan ◽  
Amit Bagchi

Abstract Combat helmets have gone through many changes, from shells made of metal to advanced composites using Kevlar and Dyneema, along with introduction of pad suspensions to provide comfort and protection. Helmets have been designed to perform against ballistic and blunt impact threats. But, in today’s warfare, combat helmets are expected to protect against all three threats, blunt, ballistic impacts and blast effects to minimize traumatic brain injury (TBI) and provide a better thermal comfort. We are developing a helmet system analysis methodology integrating the effect of multiple threats, i.e., blast and blunt impacts, to achieve an optimal helmet system design, by utilizing multi-physics computational tools. We used a validated human head model to represent the warfighter’s head. The helmet composite shell was represented by an orthotropic elasto-plastic material model. A strain rate dependent model was employed for pad suspension material. Available dynamic loading data was used to calibrate the material parameters. Multiple helmet system configurations subjected to blast and blunt loadings were considered to quantify their influence on brain biomechanical response. Parametric studies were carried out to assess energy absorption for different suspension geometry and material morphology for different loadings. The resulting brain responses were used with published injury criteria to characterize the helmet system performance through a single metric for each threat type. Approaches to combine single-threat metrics to allow aggregating performance against multiple threats were discussed.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Maria Ida Iacono ◽  
Nikos Makris ◽  
Luca Mainardi ◽  
Leonardo M. Angelone ◽  
Giorgio Bonmassar

Deep brain stimulation (DBS) is an established procedure for the treatment of movement and affective disorders. Patients with DBS may benefit from magnetic resonance imaging (MRI) to evaluate injuries or comorbidities. However, the MRI radio-frequency (RF) energy may cause excessive tissue heating particularly near the electrode. This paper studies how the accuracy of numerical modeling of the RF field inside a DBS patient varies with spatial resolution and corresponding anatomical detail of the volume surrounding the electrodes. A multiscale model (MS) was created by an atlas-based segmentation using a 1 mm3head model (mRes) refined in the basal ganglia by a 200 μm2ex-vivo dataset. Four DBS electrodes targeting the left globus pallidus internus were modeled. Electromagnetic simulations at 128 MHz showed that the peak of the electric field of the MS doubled (18.7 kV/m versus 9.33 kV/m) and shifted 6.4 mm compared to the mRes model. Additionally, the MS had a sixfold increase over the mRes model in peak-specific absorption rate (SAR of 43.9 kW/kg versus 7 kW/kg). The results suggest that submillimetric resolution and improved anatomical detail in the model may increase the accuracy of computed electric field and local SAR around the tip of the implant.