scholarly journals Application of Vibration Damping Technology in High Rise Building

2015 ◽  
Vol 9 (1) ◽  
pp. 131-134 ◽  
Author(s):  
Mingxin Huang

In recent years, Great development have been happened in the damping technique for high-rise building structure, how to build a structure which can ensure the safety of buildings in the sudden earthquake and how to adopt a new system structure which is more safe, more reasonable and more effective plays a decisive role in reducing earthquake disaster. This paper introduces the architectural structure of energy dissipation shock absorption system, isolation system, structure of passive system and structure of active control of the new system, and lists various kinds of application systems in engineering, provides reference for seismic design of engineering structure vibration.

2014 ◽  
Vol 580-583 ◽  
pp. 1551-1554
Author(s):  
Gen Tian Zhao ◽  
Xu Ting Kou

With the project case, the seismic performance of girder transfer floor member and the plate transfer floor member were discussed. Contrast calculation was carried out in girder transfer floor member and the plate transfer floor member with SATWE method to analyze its reasonable and unreasonable places. Based on overall structure calculation of a high rise building, the seismic design requirements for buildings applying thick transferring plate have been presented. The conclusion is that the seismic performance of girder transfer floor member is more advantageous and affordable, more convenient and more economical in ingredients.


2001 ◽  
Vol 7 (12) ◽  
pp. 99-104 ◽  
Author(s):  
Ichizo KAWABATA ◽  
Masaharu TAKAYAMA ◽  
Yasuhiro NISHIKAWA ◽  
Yuichi KIMURA ◽  
Eiichi YAMAZAKI ◽  
...  

2014 ◽  
Vol 584-586 ◽  
pp. 1841-1844
Author(s):  
Fang Fang Yang

Super high-rise building seismic design of complex shape is very important, can not be carried out according to the traditional design method. This paper gives a design principle based on behavior, it in the engineering design and more attention. Method based on behavior on the properties of reaction structures under earthquake is evaluated. High-rise buildings must be based on the method of state to confirm that the building to meet seismic performance.


2013 ◽  
Vol 351-352 ◽  
pp. 536-540
Author(s):  
Jing Yuan Ma ◽  
Fu Ma ◽  
Chen Suo Hu ◽  
Zhi Xian Wen

This article summarized seismic design method of high-rise building from seismic fortification goal, use of materials, structural systems, analysis methods and trends. Then it discussed the structural design significance of high-rise buildings to achieve sustainable development. Lightweight quality, high strength material, diversity type, spatial component, braced lateral force resisting system, structuring combination and shock absorption building are the trends of high-rise building development.


2013 ◽  
Vol 353-356 ◽  
pp. 1875-1878
Author(s):  
Ling Huang

The application of performance-based seismic design method in super high-rise building is studied in this article. The two-stage design process of a super high-rise building is introduced. On the base of proposing the performance standards and objectives of the super high-rise building under earthquake actions of different levels, optimal solution is provided after computational analyses with different softwares. Computational analyses indicate that the design could satisfy all seismic fortification requirements and seismic performance objectives of China's seismic codes in force. The performance-based design idea can provide a reference for similar projects.


2013 ◽  
Vol 423-426 ◽  
pp. 1230-1233
Author(s):  
Ting Yu Mei ◽  
Lang Wu

In recent years, high-rise buildings have developed very rapidly in our country. Because of the particularity of the high-rise building, more strictly technical measures should be taken in seismic design to ensure security. Three level fortifications, two stage design method have been used for seismic design in our country. Combined with the practical, the key points of response spectrum, time history analysis and performance design which related to seismic design of high-rise buildings were analyzed.


2021 ◽  
Vol 28 (2) ◽  
pp. 125-132
Author(s):  
Alif Muhammad Reza ◽  
Herlien D. Setio

Abstract Various studies have been carried out to evaluate the feasibility and effectiveness of the story isolation system. The results obtained are also quite impressive, where the story isolation system gave a better story drift reduction than the base isolation system. However, these studies only focused on low-rise buildings, even though the story isolation system will be more engaging if it could also be compatible with high-rise buildings. In this study, a numerical analysis will be carried out on 30-, 40-, 50-, and 60-story buildings to evaluate the story isolator’s location, so that the system gives an optimum reduction of story drift and story shear. Then a general solution is sought to become a reference for buildings with different plans and heights. Keywords: Story isolation system, story isolator optimum location, high-rise building. Abstract Berbagai penelitian telah dilakukan untuk mengevaluasi kelayakan dan efektivitas sistem isolasi tingkat. Hasil yang diperoleh juga cukup mengesankan, dimana sistem isolasi tingkat memberikan reduksi simpangan antar tingkat yang lebih baik dibandingkan dengan sistem isolasi dasar. Namun, studi tersebut hanya berfokus pada bangunan bertingkat rendah, padahal sistem isolasi lantai akan lebih menarik jika dapat juga digunakan pada bangunan bertingkat tinggi. Dalam studi ini, analisis numerik akan dilakukan pada bangunan berlantai 30, 40, 50, dan 60 untuk mengevaluasi lokasi isolator tingkat yang memberikan reduksi simpangan tingkat dan geser tingkat terbesar. Kemudian dicari solusi umum untuk menjadi acuan untuk bangunan dengan denah dan ketinggian yang berbeda. Kata kunci: Sistem isolasi tingkat, lokasi optimum isolator tingkat, bangunan bertingkat tinggi.


Sign in / Sign up

Export Citation Format

Share Document