scholarly journals Wheeze Recognition Algorithm for Remote Medical Care Device in Children: Validation Study (Preprint)

2021 ◽  
Author(s):  
Chizu Habukawa ◽  
Naoto Ohgami ◽  
Takahiko Arai ◽  
Haruyuki Makata ◽  
Morimitsu Tomikawa ◽  
...  

BACKGROUND Since 2020, peoples’ lifestyles have been largely changed due to the COVID-19 pandemic worldwide. In the medical field, although many patients prefer remote medical care, this prevents the physician from examining the patient directly; thus, it is important for patients to accurately convey their condition to the physician. Accordingly, remote medical care should be implemented and adaptable home medical devices are required. However, only a few highly accurate home medical devices are available for automatic wheeze detection as an exacerbation sign. OBJECTIVE We developed a new handy home medical device with an automatic wheeze recognition algorithm, which is available for clinical use in noisy environments such as a pediatric consultation room or at home. Moreover, the examination time is only 30 seconds, since young children cannot endure a long examination time without crying or moving. The aim of this study was to validate the developed automatic wheeze recognition algorithm as a clinical medical device in children at different institutions. METHODS A total of 374 children aged 4-107 months in pediatric consultation rooms of 10 institutions were enrolled in this study. All participants aged ≥6 years were diagnosed with bronchial asthma and patients ≤5 years had reported at least three episodes of wheezes. Wheezes were detected by auscultation with a stethoscope and recorded for 30 seconds using the wheeze recognition algorithm device (HWZ-1000T) developed based on wheeze characteristics following the Computerized Respiratory Sound Analysis guideline, where the dominant frequency and duration of a wheeze were >100 Hz and >100 ms, respectively. Files containing recorded lung sounds were assessed by each specialist physician and divided into two groups: 177 designated as “wheeze” files and 197 as “no-wheeze” files. Wheeze recognitions were compared between specialist physicians who recorded lung sounds and those recorded using the wheeze recognition algorithm. We calculated the sensitivity, specificity, positive predictive value, and negative predictive value for all recorded sound files, and evaluated the influence of age and sex on the wheeze detection sensitivity. RESULTS Detection of wheezes was not influenced by age and sex. In all files, wheezes were differentiated from noise using the wheeze recognition algorithm. The sensitivity, specificity, positive predictive value, and negative predictive value of the wheeze recognition algorithm were 96.6%, 98.5%, 98.3%, and 97.0%, respectively. Wheezes were automatically detected, and heartbeat sounds, voices, and crying were automatically identified as no-wheeze sounds by the wheeze recognition algorithm. CONCLUSIONS The wheeze recognition algorithm was verified to identify wheezing with high accuracy; therefore, it might be useful in the practical implementation of asthma management at home. Only a few home medical devices are available for automatic wheeze detection. The wheeze recognition algorithm was verified to identify wheezing with high accuracy and will be useful for wheezing management at home and in remote medical care.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Ari Fahrial Syam ◽  
Muhammad Miftahussurur ◽  
Willy Brodus Uwan ◽  
David Simanjuntak ◽  
Tomohisa Uchida ◽  
...  

We measured the accuracy of the urine test (RAPIRUN) for detection ofHelicobacter pyloriinfection in Indonesia (Jakarta, Pontianak, and Jayapura) using histology confirmed by immunohistochemistry and/or culture as gold standards. We also used immunohistochemistry to identify CagA phenotype and analyzedH. pyloriCagA diversity in Indonesia. The overall prevalence ofH. pyloriinfection in 88 consecutive dyspeptic patients based on the urine test was 15.9% (14/88), 38.1% for patients in Jayapura that had higher prevalence ofH. pyloriinfection than that in Jakarta (9.7%,P=0.02) and Pontianak (8.3%,P=0.006). Overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of RAPIRUN were 83.3%, 94.7%, 71.4%, 97.3%, and 93.2%, respectively. All of theH. pylori-positive patients were immunoreactive for anti-CagA antibody but not immunoreactive for East Asian specific anti-CagA antibody in allH. pylori-positive subjects. We confirmed the high accuracy of RAPIRUN in Indonesian population. In general, we found less virulent type ofH. pyloriin Indonesia, which partly explained the low incidence gastric cancer in Indonesia.



2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>



2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.



2017 ◽  
pp. 59-63
Author(s):  
Thanh Hung Dieu ◽  
Anh Vu Nguyen

Objects: We assessed the ability of ST-segment elevation in lead aVR to predict left main and/or 3-vessel disease (LM/3VD) in patients with acute coronary syndromes (ACS). Meterial and Method: 410 patients with ACS, who underwent coronary angiography, were evaluated. Results: 131 (31.9%) patients have been LM/3VD. ST segment elevation > 0.05 mV in leads aVR have been an independent predictor LM/3VD with sensitivity, specificity, positive predictive value PPV) and negative predictive value (NPV) 74.0%, 78.1%, 61.4% and 86.5%, respectively (p<0.001). ST segment elevation > 0.05 mV in leads aVR with ST segment depression in leads V4-V6 have related LM/3VD with sensitivity, specificity, PPV and NPV 44.3%, 92.8%, 74.4% and 75.2%, respectively (p<0.001). ST segment elevation > 0.1 mV in leads aVR have related LM/3VD with sensitivity, specificity, PPV and NPV 51.9%, 87.1%, 65.1% and 79.4%, respectively (p<0.001). Conclusions: ST segment elevation > 0.05 mV in leads aVR have been an independent predictor LM/3VD in patients with ACS. Key words: Acute coronary syndromes, ST-segment elevation, aVR



2008 ◽  
Vol 47 (04) ◽  
pp. 163-166 ◽  
Author(s):  
D. Steiner ◽  
S. Laurich ◽  
R. Bauer ◽  
J. Kordelle ◽  
R. Klett

SummaryIn not infected knee prostheses bone scintigraphy is a possible method to diagnose mechanical loosening, and therefore, to affect treatment regimes in symptomatic patients. However, hitherto studies showed controversial results for the reliability of bone scintigraphy in diagnosing loosened knee prostheses by using asymptomatic control groups. Therefore, the aim of our study was to optimize the interpretation procedure and to evaluate the accuracy using results from revision surgery as standard. Methods: Retrospectively, we were able to examine the tibial component in 31 cemented prostheses. In this prostheses infection was excluded by histological or bacteriological examination during revision surgery. To quantify bone scintigraphy, we used medial and lateral tibial regions with a reference region from the contralateral femur. Results: To differentiate between loosened and intact prostheses we found a threshold of 5.0 for the maximum tibia to femur ratio of the both tibial regions and a threshold of 18% for the difference of the ratio of both tibial regions. Using these thresholds, values of 0.9, 1, 0.85, 1, and 0.94 were calculated for sensitivity, specificity, negative predictive value, positive predictive value, and accuracy, respectively. To get a sensitivity of 1, we found a lower threshold of 3.3 for the maximum tibia to femur ratio. Conclusion: Quantitative bone scintigraphy appears to be a reliable diagnostic tool for aseptic loosening of knee prostheses with thresholds evaluated by revision surgery results being the golden standard.



2020 ◽  
Vol 103 (6) ◽  
pp. 585-593

Objective: To evaluate the accuracy of transvaginal ultrasonography (TVS) and saline infusion sonography (SIS) in use for the diagnosis of endometrial polyps and submucous myoma compared to hysteroscopy. Histopathology was considered as the gold standard for final diagnosis. Materials and Methods: The present retrospective study was conducted at Bhumibol Adulyadej Hospital, Bangkok, Thailand between January 2014 and December 2017. Medical records of 150 patients who attended for hysteroscopy and histopathological diagnosis were reviewed. The accuracy of TVS and SIS for the diagnosis of endometrial polyps and submucous myoma were determined. Results: Out of 150 enrolled cases, endometrial polyp was the most frequent hysteroscopic finding in participants of the present study (92/150). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of TVS, SIS, and hysteroscopy compared to pathologic reports for detection endometrial polyps were 71.7% versus 93.5% versus 97.8%, 38.5% versus 52.2% versus 68.2%, 80.5% versus 88.7% versus 92.8%, 27.8% versus 66.7% versus 88.2%, and 64.4% versus 85.2% versus 92.1%, respectively. The sensitivity, specificity, PPV, NPV, and accuracy of TVS, SIS, and hysteroscopy for detection of submucous myoma were 81.6% versus 92.1% versus 94.7%, 66.7% versus 86.9% versus 100%, 77.5% versus 92.1% versus 100%, 72.0% versus 86.9% versus 90.9%, and 75.4% versus 90.2% versus 96.6%, respectively. The kappa value from TVS, SIS, and hysteroscopy when the histopathologic reports were overall intrauterine abnormalities, endometrial polyps and submucous myoma were 0.45/0.43/0.72, 0.77/0.76/0.89, and 0.92/0.92/1.00, respectively. Conclusion: Sensitivity, specificity, PPV, NPV, accuracy, and kappa value of SIS for detecting endometrial polyps and submucous myoma were better than TVS. Keywords: Ultrasonography, Saline infusion sonography, Hysteroscopy, Accuracy



2020 ◽  
Vol 08 (11) ◽  
pp. E1623-E1632
Author(s):  
Carlos Robles-Medranda ◽  
Roberto Oleas ◽  
Miguel Puga-Tejada ◽  
Manuel Valero ◽  
Raquel Del Valle ◽  
...  

Abstract Background and study aims Assessment of endoscopic ultrasonography (EUS)-elastography of the liver and spleen may identify patients with portal hypertension secondary to chronic liver disease. We aimed to evaluate use of EUS-elastography of the liver and spleen in identification of portal hypertension in patients with chronic liver disease. Patients and methods This was a single-center, diagnostic cohort study. Consecutive patients with liver cirrhosis and portal hypertension underwent EUS-elastography of the liver and spleen. Patients without a history of liver disease were enrolled as controls. The primary outcome was diagnostic yield of liver and spleen stiffness measurement via EUS-elastography in prediction of portal hypertension secondary to chronic liver cirrhosis. Cutoff values were defined through Youden’s index. Overall accuracy was calculated for parameters with an area under the receiver operating characteristic (AUROC) curve ≥ 80 %. Results Among the 61 patients included, 32 had cirrhosis of the liver. Liver and spleen stiffness was measured by the strain ratio and strain histogram, with sensitivity/(1 − specificity) AUROC values ≥ 80 %. For identification of patients with cirrhosis and portal hypertension, the liver strain ratio (SR) had a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 84.3 %, 82.8 %, 84.4 %, and 82.8 %, respectively; the liver strain histogram (SH) had values of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively. EUS elastography of the spleen via the SR reached a sensitivity, specificity, PPV, and NPV of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively, whereas the values of SH were 56.3 %, 89.7 %, 85.7 %, and 65.0 %, respectively. Conclusion Endoscopic ultrasonographic elastography of the liver and spleen is useful for diagnosis of portal hypertension in patients with cirrhosis.



2021 ◽  
pp. 095646242110222
Author(s):  
Thomas Juniper ◽  
Chris P Eades ◽  
Eliza Gil ◽  
Harriet Fodder ◽  
Killian Quinn ◽  
...  

Objectives: An elevated serum (1-3)-β-D-glucan (BDG) concentration has high sensitivity for a diagnosis of Pneumocystis pneumonia (PCP) in people with HIV (PWH). At the current manufacturer-recommended positive threshold of 80 pg/mL (Fungitell), specificity for PCP is variable and other diagnostic tests are required. We evaluated the utility of serum BDG for diagnosis of suspected PCP in PWH at three inner-London hospitals to determine BDG concentrations for diagnosis and exclusion of PCP. Methods: From clinical case records, we abstracted demographic and clinical information and categorised patients as having confirmed or probable PCP, or an alternative diagnosis. We calculated sensitivity, specificity and positive predictive value (PPV) of serum BDG concentrations >400 pg/mL and negative predictive value (NPV) of BDG <80 pg/mL. Results: 76 patients were included; 29 had laboratory-confirmed PCP, 17 had probable PCP and 30 had an alternative diagnosis. Serum BDG >400 pg/mL had a sensitivity of 83%, specificity of 97% and PPV 97% for diagnosis of PCP; BDG <80 pg/mL had 100% NPV for exclusion of PCP. Conclusions: In PWH with suspected PCP, BDG <80 pg/mL excludes a diagnosis of PCP, whereas BDG concentrations >400 pg/mL effectively confirm the diagnosis. Values 80–400 pg/mL should prompt additional diagnostic tests.



Author(s):  
Sushma S. ◽  
Medha Y Rao ◽  
Shaikh Mohammed Aslam

Abstract Background Studies in healthy elderly patients have shown the prevalence of autonomic dysfunction (AD) in the range of 20 to 30%. However, there is paucity in data pertaining to AD in the elderly in the Indian context. Objective To assess the prevalence of AD in the elderly irrespective of their comorbidity status. Methods A total of 141 elderly patients with or without comorbidities/symptoms of AD were included. Demographic and clinical details of the patients were recorded. Autonomic function tests (AFTs) such as deep breathing test, Valsalva ratio, orthostatic heart rate (OHR), isometric handgrip test, and orthostatic blood pressure were performed based on Ewing’s battery of tests. The sensitivity, specificity, positive predictive value, negative predictive value, and the accuracy of AFTs were evaluated. Results Most patients (n = 85) were aged between 60 and 69 years, with a male predominance (58.87%). Hypertension and diabetes mellitus were the most common comorbidities. Postural hypotension was the most common symptom of AD. With advancing age, symptoms of AD manifested significantly more. Overall, 73.8% of patients had AD, of whom 45.4% had early AD. Number of AD symptoms, glycated hemoglobin (HbA1c) level, and comorbid factors (diabetes and hypertension) were significantly associated with the results of AFTs (p < 0.05). AFTs were highly significant with respect to the results obtained (p < 0.001). Deep breathing test, abnormal in majority of study patients, has a sensitivity of 93.3% and OHR has a specificity of 81.1% to determine AD. Conclusion The study concludes that age itself is an independent predictor of AD, which increases in severity if associated with comorbidities.



Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1110
Author(s):  
Andrea Ronchi ◽  
Marco Montella ◽  
Federica Zito Marino ◽  
Michele Caraglia ◽  
Anna Grimaldi ◽  
...  

Background: Cutaneous malignant melanoma is an aggressive neoplasm. In advanced cases, the therapeutic choice depends on the mutational status of BRAF. Fine needle aspiration cytology (FNA) is often applied to the management of patients affected by melanoma, mainly for the diagnosis of metastases. The evaluation of BRAF mutational status by sequencing technique on cytological samples may be inconvenient, as it is a time and biomaterial-consuming technique. Recently, BRAF immunocytochemistry (ICC) was applied for the evaluation of BRAF V600E mutational status. Although it may be useful mainly in cytological samples, data about BRAF ICC on cytological samples are missing. Methods: We performed BRAF ICC on a series of 50 FNA samples of metastatic melanoma. BRAF molecular analysis was performed on the same cytological samples or on the corresponding histological samples. Molecular analysis was considered the gold standard. Results: BRAF ICC results were adequate in 49 out of 50 (98%) cases, positive in 15 out of 50 (30%) cases and negative in 34 out of 50 (68%) of cases. Overall, BRAF ICC sensitivity, specificity, positive predictive value and negative predictive value results were 88.2%, 100%, 100% and 94.1%, respectively. The diagnostic performance of BRAF ICC results was perfect when molecular evaluation was performed on the same cytological samples. Hyperpigmentation represents the main limitation of the technique. Conclusions: BRAF ICC is a rapid, cost-effective method for detecting BRAF V600E mutation in melanoma metastases, applicable with high diagnostic performance to cytological samples. It could represent the first step to evaluate BRAF mutational status in cytological samples, mainly in poorly cellular cases.



Sign in / Sign up

Export Citation Format

Share Document