scholarly journals SIMPLE QUANTIFIED AND VALIDATED STABILITY INDICATING STRESS DEGRADATION STUDIES OF ORAL ANTI-DIABETIC AGENT DAPAGLIFLOZIN BY RP-HPLC METHOD

Author(s):  
ARULSELVAN MURUGESAN ◽  
MUKTHINUTHALAPATI MATHRUSRI ANNAPURNA

Objective: This method is focused on developing a precisely simplified and more accurate Reverse Phase–High Pressure Liquid Chromatography (RP-HPLC) method for the determination of Dapagliflozin in bulk and pharmaceutical dosage form as per guidelines of International Council for Harmonization (ICH). Methods: Evaluation and validation carried out using the RP-HPLC ZORBAX (C18) column (250 x 4.6 mm, 5 μm particle size) with a mobile phase consisting of Phosphate Buffer: Acetonitrile: Methanol in a ratio of 55:40:05 (v/v/v) at a flow rate of 1 ml/min with an injection volume of 10 μl. Results: Dapagliflozin was eluted at 2.12±0.05 min and detected at 225 nm. The regression equation y = 55762 x-29679 found to be linear with correlation coefficient r2 value of 0.9997. The developed RP-HPLC method was conveniently validated as per the ICH guidelines and found method was robust, sensitive, accurate, selective, specific, precise and linear. Conclusion: The proposed method was found to be accurate, precise, and robust for API and pharmaceutical dosage form as per experimentation analysis. The above developed method was found to be satisfied for Active Pharmaceutical Ingredient (API) and pharmaceutical formulation of Dapagliflozin to study its degradation products.

Author(s):  
Abhishek Agrawal ◽  
Prem Kumar Bichala ◽  
Swapna Singh

RP-HPLC method was developed for the determination for the validation of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. Chromatographic separation was performed on Develosil ODS HG-5 RP C18, 15x4.6mm, 5µm column, with mobile phase comprising of mixture of ACN: Methanol: Citric acid in the ratio of 50:45:5 v/v, at the flow rate 1.0ml/min and the detection was carried out at 296nm. The comprehensive forced stress testing has been carried out as per USP guidelines. The drug Nitazoxanide is subjected to synthetic Benzamide, and the drug Ofloxacin is subject to synthetic Fluoroquinolone. RP- HPLC method was developed to separate analyte from all other degradation peaks. The method was successfully validated as per ICH guidelines for the purpose of conducting studies of the analyte in quality control laboratory. The drug was subjected to different degradation conditions; it was found to be stable in all degradation conditions. The purposed HPLC method was found to be precise, specific, accurate, rapid and economical for the determination of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. The sample recoveries in all formulations were in good agreement with their respective label claims and this method can be used for routine analysis. The linearity range was found to be 0-50 (µg/ml) for Nitazoxanide and 0-50 (µg/ml) for Ofloxacin. Calibration curve was plotted and correlation co-efficient for the drugs found to be 0.999 and 0.997. Hence the results obtained were within the limits.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
M. V. Basaveswara Rao ◽  
A. V. D Nagendrakumar ◽  
Sushanta Maiti ◽  
N. Chandrasekhar

A simple, selective, linear, precise, and accurate RP-HPLC method was developed and validated for rapid assay of Pizotifen in pharmaceutical dosage form. Isocratic elution at a flow rate of 1.0 mL/min was employed on Chromosil C18 (250 mm × 4.6 mm, 5 μm) column at ambient temperature. The mobile phase consists of methanol : acetonitrile in the ratio of 10 : 90 v/v. The UV detection wavelength was 230 nm, and 20 μL sample was injected. The retention time for Pizotifen was 2.019 min. The percent RSD for accuracy of the method was found to be 0.2603%. The method was validated as per the ICH guidelines. The method can be successfully applied for routine analysis of Pizotifen in the rapid and reliable determination of Pizotifen in pharmaceutical dosage form.


Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


Author(s):  
Alex O. Okaru ◽  
Kennedy O. Abuga ◽  
Franco N. Kamau ◽  
Stanley N. Ndwigah ◽  
Dirk W. Lachenmeier

A simple, isocratic and robust RP-HPLC method for the analysis of azithromycin was developed, validated and applied for the analysis of bulk samples, tablets and suspensions. The optimum chromatographic conditions for separation were established as mobile phase comprising of acetonitrile-0.1M KH2PO4 pH 6.5-0.1M tetrabutyl ammonium hydroxide pH 6.5-water (25:15:1:59% v/v/v/v) delivered at a flow rate of 1.0 ml/min. The stationary phase consisted of reverse-phase XTerra® (250 mm× 4.6 mm i.d., 5 µm particle size) maintained at a temperature of 43 °C with a UV detection at 215 nm. The method was found to be linear in the range 50-150% (r2=0.997). The limits of detection and quantification were found to be 0.02% (20 µg) and 0.078% (78 µg) respectively with a 100.7% recovery of azithromycin. Degradation products of azithromycin in acidic and oxidative environments at 37 °C were resolved from the active pharmaceutical ingredient and thus the method is fit for the purpose of drug stability confirmation.


Author(s):  
Sireesha D ◽  
Sai Lakshmi E ◽  
Sravya E ◽  
Vasudha Bakshi

A new simple, rapid, specific, accurate, precise and novel Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the estimation of Sitagliptin Phosphate in the pharmaceutical dosage form. The chromatographic separation for Sitagliptin was achieved with mobile phase containing methanol, Thermoscientific C18 column, (250x4.6 particle size of 5μ) at room temperature and UV detection at 248 nm. The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Sitagliptin was 1.91min. The above method was validated in terms of linearity, accuracy, precision, LOD and LOQ in accordance with ICH guidelines.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (02) ◽  
pp. 20-33
Author(s):  
N. S Kumar ◽  
◽  
R Kumaraswamy ◽  
S. Shantikumar ◽  
D. Paul

The present study describes the separation and simultaneous estimation of eight anti-retroviral drugs, namely, Telaprevir (TPV), Emtricitabine (ECB), Fosamprenavir (FANV), Tenofavir (TNF), Ritonavir (RNV), Raltegravir (RGV) and Oseltamivir (OSMV) and Zidovudine (ZDV) as an active pharmaceutical ingredient, by RP-HPLC method by applying the principles of Quality by Design (QbD). An application of DoE (Design of Experiments) full factorial design was used for initial screening and optimization. The final optimized method consists of separation being carried out on a Fortis C18 column (150 mm × 4.6 mm, 5μ particle size) using acetonitrile and 10 mm ammonium formate buffer (pH 3 adjusted with formic acid) using a gradient program. The quantitative evaluation was performed with a diode array detector at 251 nm and 230 nm with a flow rate of 1 mL min–1. Suitability of this method for the quantitative determination of the drugs was proved by validation in accordance with the International Conference on Harmonization (ICH) guidelines. The method is selective, precise, robust and accurate and can be used for routine analysis of pharmaceutical formulations in quality control and counterfeit screening.


Author(s):  
Sushil D. Patil ◽  
Pravin B. Shelke ◽  
Priti Aher ◽  
Maswood Ahmed Hafizur Rahman

A simple, rapid, economic, sensitive and precise HPLC method has been developed for the simultaneous determination of Sulphadoxine and Pyrimethamine in pharmaceutical dosage form by taking Tolterodine as an internal standard. The method was carried out using Phenomenex C18 (4.6ID × 250mm; 5µm) column and mobile phase comprised of methanol and Phosphate Buffer in proportion of ratio 60:40 v/v. The flow rate was 1.0mL/min and detection was carried out at 276nm. The retention time of Sulphadoxine, Pyrimethamine and Tolterodine were found to be 2.967, 4.058 and 6.908 respectively. Linearity of Sulphadoxine and Pyrimethamine in the range of 2 to 12μg/mL and 4 to 24μg/mL respectively. The % recoveries of Sulphadoxine and Pyrimethamine were found to be in between 99.93% to 99. 96 % respectively. The proposed method is suitable for the routine quality control analysis for simultaneous determination of Sulphadoxine and Pyrimethamine was in bulk and pharmaceutical dosage form.


Author(s):  
Sumithra M

Objective: The objective of the study is simple, sensitive; eco-friendly reverse phase chromatographic method has been developed and validated for the quantitative determination of ofloxacin in bulk and marketed formulation. Method: The developed method was done using Hypersil silica C18 (250 mm × 4.6 mm, 5 μ particle size) as column and the mobile phase is containing water and methanol in the ratio of (10:90) vol/vol. The mobile phase pass at 1 ml/min flow rate and the eluted solution is measured at 270 nm using a PDA detector. Results: The assay method is linear from the concentration range of 5–30 μg/ml. The corelation coefficient is 0.9998. The mean percentage recovery for the developed method is found to be in the range of 98.4–100.6%. The developed method complies robustness studies. Conclusion: The validation of the developed method was done by as per the ICH guidelines. It obeys the linearity, accuracy, precision, and robustness studies. Validation parameters are within the limitations. The results of the developed process indicated the reverse phase chromatographic method is simple, accurate as well as precise, rapid and eco-friendly method for routine analysis of ofloxacin in bulk and its pharmaceutical dosage form.


Sign in / Sign up

Export Citation Format

Share Document