scholarly journals Direct Temperature Measurement of Al-2mass%Si Alloy Strips during High-Speed Twin-Roll Casting and Its Application in Determining Melt/Roll Heat Transfer Coefficient for Simulation

2017 ◽  
Vol 58 (6) ◽  
pp. 967-970 ◽  
Author(s):  
Min-Seok Kim ◽  
Hyoung-Wook Kim ◽  
Shinji Kumai
Author(s):  
Ankit Kalani ◽  
Satish G. Kandlikar

Flow boiling in microchannels offers many advantages such as high heat transfer coefficient, higher surface area to volume ratio, low coolant inventory, uniform temperature control and compact design. The application of these flow boiling systems has been severely limited due to early critical heat flux (CHF) and flow instability. Recently, a number of studies have focused on variable flow cross-sectional area to augment the thermal performance of microchannels. In a previous work, the open microchannel with manifold (OMM) configuration was experimentally investigated to provide high heat transfer coefficient coupled with high CHF and low pressure drop. In the current work, high speed images of plain surface using tapered manifold are obtained to gain an insight into the nucleating bubble behavior. The mechanism of bubble nucleation, growth and departure are described through high speed images. Formation of dry spots for both tapered and uniform manifold geometry is also discussed.


2000 ◽  
Author(s):  
G. Hetsroni ◽  
M. Gurevich ◽  
A. Mosyak ◽  
R. Rozenblit ◽  
L. P. Yarin

Abstract During subcooled boiling of pure water and water with cationic surfactants, the motion of bubbles and the temperature of the heated surface were recorded by both a high-speed video camera and an infrared radiometer. The results show that the bubble behavior and the heat transfer mechanism for the surfactant are quite different from those of clear water. Bubbles formed in Habon G solutions were much smaller man those in water and the surface was covered with them faster. Boiling hysteresis is found for degraded solutions. Dependencies of heat transfer coefficient for various solutions were obtained and compared. The boiling curves of surfactant are quite different from the boiling curve of pure water. Experimental results demonstrate that the heat transfer coefficient of the boiling process can be enhanced considerably by the addition of a small amount of Habon G. The experiments show that the limitations of the ER technique with respect to frequency response are outweighed by its unique capacity to measure wall temperature distribution with high spatial resolution over an area encompassing many nucleation sites and over long periods.


Author(s):  
Susan N. Ritchey

Shell-and-tube vacuum condensers are present in many industrial applications such as chemical manufacturing, distillation, and power production [1–3]. They are often used because operating a condenser under vacuum pressures can increase the efficiency of energy conversion, which increases the overall plant efficiency and saves money. Typical operating pressures in the petrochemical industry span a wide range of values, from one atmosphere (101.3 kPa) down to a medium vacuum (1 kPa). The current shellside condensation methods used to predict heat transfer coefficients are based on data collected near or above atmospheric pressure, and the available literature on shellside vacuum condensation generally lacks experimental data. The accuracy of these methods in vacuum conditions well below atmospheric pressure has yet to be validated. Recently, HTRI designed and constructed the Low Pressure Condensation Unit (LPCU) with a rectangular shellside test condenser. To date, heat transfer data have been collected in the LPCU for shellside condensation of a pure hydrocarbon and of a hydrocarbon with noncondensable gas at vacuum pressures ranging from 2.8 to 45 kPa (21 to 338 Torr). Traditional condensation literature methods underpredict the overall heat transfer coefficient by 20.8% ± 20.4% for the pure condensing fluid; whereas they overpredict heat transfer by 36.8% ± 40.0% with the addition of the noncondensable gas. Over or under predicting the overall heat transfer coefficient in the presence of noncondensable gases leads to inefficient condenser designs and the inability to achieve desired process conditions. With the addition of the noncondensable gas, the measured heat exchanger duty was significantly reduced compared to the pure fluid, even at inlet mole fractions below 5%. In one case, a noncondensable inlet mole fraction of 0.63% was estimated to reduce the duty by approximately 10%. Analysis of the acquired high-speed videos shows that the film thickness changes significantly from the top row to the bottom. The videos also display condensate drainage patterns and droplet interactions. The ripples and splashing of the condensate observed in the videos indicates that the Nusselt idealized model is not appropriate for analysis of a real condenser. This article presents the collected heat transfer data and high-speed images of shellside vacuum condensation flow patterns.


2010 ◽  
Vol 154-155 ◽  
pp. 1544-1548 ◽  
Author(s):  
Kosuke Komeda ◽  
Ryoji Nakamura ◽  
Shinji Kumai

The disadvantages of the conventional twin-roll caster for aluminum alloy are low casting speeds and limited choices of alloys that are castable by this processing. It is known that strip casting of aluminum alloy 5182 is very difficult because of their wider freezing zones. The vertical-type high-speed twin-roll caster used in the present study was devised to overcome these disadvantages. Features of the high speed twin roll casters are as below. Mild steel rolls were used in order to increase the casting speed and to be made at a lower equipment cost. Roll coating is produced in casting of Al-Mg alloy. Therefore lubricant, that resists heat transfer, was not used in the present study. Heat transfer between melt and the roll was improved by hydrostatic pressure of the melt. Low superheat casting was carried out in order to improve microstructure of the strip. In the present study, effectiveness of a high-speed twin roll caster for recycling aluminum alloy was investigated. The effects of the high-speed twin roll caster on alleviating the deterioration of mechanical properties by impurities were investigated. Properties of the cast strip were investigated by metalography, a tension test, and a deep drawing test.


2013 ◽  
Vol 448-453 ◽  
pp. 3316-3319
Author(s):  
Chuang Sun ◽  
Yang Zhao ◽  
De Fu Li ◽  
Qing Ai ◽  
Xin Lin Xia

According to the view of heat transfer, the process of the fluid flow with high temperature and high speed over a flat plate may be considered as the heat transfer process within a compressible thermal boundary layer. Based on the numerical results of thermal isolation assumption, combining the temperature comparison with modification method, a coupled method of convection heat transfer coefficient with temperature field of the plate is established, and the characteristics of the thermal response for the flat plate is dominated. Take some ribbed plates as instances, the convection heat transfer coefficient and temperature field of the plate are simulated through the provided coupled method. The results show that, not only the position and materials of the plate influence the convection heat transfer coefficient, but also the time.


Author(s):  
Simon Jacobi ◽  
Budimir Rosic

This paper presents a thermal investigation of the Integrated Combustor Vane concept for power generation gas turbines with individual can combustors. This concept has the potential to replace the high-pressure turbine’s first vanes by prolonged combustor walls. Experimental measurements are performed on a linear high-speed cascade consisting of two can combustors and two integrated vanes. The modularity of the facility allows for the testing at engine-realistic high turbulence levels, as well as swirl strengths with opposing swirl directions. The heat transfer characteristics of the integrated vanes are compared to conventional nozzle guide vanes. The experimental measurements are supported by detailed numerical simulations using the inhouse CFD code TBLOCK. Experimental as well as numerical results congruently indicate a considerable reduction of the heat transfer coefficient (HTC) on the integrated vanes surfaces and endwalls caused by a differing state of boundary layer thickness. The studies furthermore depict a slight, non-detrimental shift in the heat transfer coefficient distributions and the strength of the integrated vanes secondary flows as a result of engine-realistic combustor swirl.


2011 ◽  
Vol 299-300 ◽  
pp. 1005-1011 ◽  
Author(s):  
Ming Xin Gao ◽  
Pei Long Wang ◽  
Hao Jia ◽  
Shan Hu Tong ◽  
Hua Song ◽  
...  

When rolled heavy rail is on the cooling bed for natural cooling, the heat transfer coefficient has important effect on the bending and section sizes of cooled heavy rail. In the paper, the heat-stress couple module ofANSYS software is adopted to carry on numerical simulation on the cooling process of 60kg/m U75V heavy rail, and we obtain the change rule that heat transfer coefficient has effect on bending curvature and section sizes of cooled heavy rail. This study is of great reference value on cooling bed design and the formulation of cooling technological parameters for high speed heavy rail.


Author(s):  
V. P. Sidorov ◽  
◽  
D. E. Sovetkin ◽  

The paper considers the features of energy release in a tungsten electrode under the reverse polarity TIG welding. The study substantiates the statement that the chemical composition of an electrode does not significantly affect the transfer of anode power to it. The specific effective power of an electrode is substantiated and taken as 6 W/A. The authors analyzed the features of arcing on the flat tip of a 3 mm diameter electrode using high-speed video. The analysis identified that at limiting currents ensuring tip melting, the tip heating is uniform over the cross-section. As a design scheme, the authors selected a continuous flat heat source on the semi-infinite rod surface with surface heat transfer. The authors obtained averaged values for volumetric heat capacity сρ=3.2 J/(cm3∙°С) and heat transfer coefficient а=0.3 cm2/s. The current at which the tip melting temperature is reached was taken as a limiting current. Using the limiting current value and start time of the electrode tip melting, the authors calculated the electrode heat transfer coefficient value b. The calculated melting depth for the over-limiting current welding mode showed good coincidence with an experiment. The authors recalculated the b value for the electrodes of 4-, 5-, and 6-mm diameter and calculated limiting currents for these diameters. The design limiting currents for these diameters also showed good coincidence with experimental results. The study showed that the increase of a coefficient up to 0.4 cm2/s does not cause changes in temperature and limiting currents at simultaneous сρ adjustment according to the constant thermal and physical properties сρа0.5. As a result, the authors obtained temperature dependencies for the electrode over time and length. Time dependence of the electrode tip heating allows calculating limiting currents with the decrease in arcing time.


Sign in / Sign up

Export Citation Format

Share Document