scholarly journals Study of the piezoelectric sensor KD-35 properties on the calibration device by the method of external pulse and on a real Earth track

2017 ◽  
Vol 38 (6) ◽  
pp. 173-179
Author(s):  
S.V. Shcherbina ◽  
Yu.V. Lisovyi ◽  
A.I. Feschenko ◽  
O.I. Brickyi
Author(s):  
Nik Ahmad Zainal Abidin ◽  
◽  
Norkharziana Mohd Nayan ◽  
Azuwa Ali ◽  
N. A. Azli ◽  
...  

This research presents a simulation analysis for the AC-DC converter circuit with a different configurations of the array connection of the piezoelectric sensor. The selection of AC-DC converter circuits is full wave bridge rectifier (FWBR), parallel SSHI (P-SSHI) and parallel voltage multiplier (PVM) with array configuration variation in series (S), parallel (P), series-parallel (SP) and parallel-series (PS). The system optimizes with different load configurations ranging from 10 kΩ to 1 MΩ. The best configuration of AC-DC converter with an appropriate array piezoelectric connection producing the optimum output of harvested power is presented. According to the simulation results, the harvested power produced by using P-SSHI converter connected with 3 parallel piezoelectric transducer array was 85.9% higher than for PVM and 15.88% higher than FWBR.


Author(s):  
Qibo Mao ◽  
Yuande Wang ◽  
Shizuo Huang

In this study, a new methodology is presented to detect the sensor fault for piezoelectric array based on the filtered frequency response function (FRF) shapes. The proposed method does not require prior knowledge about healthy piezoelectric array. First, the imaginary parts of FRFs from the piezoelectric array during vibration are measured and normalized to obtain the FRF shapes in different frequencies. Then the irregularities in these FRF shapes are extracted by using high-pass filter with properly chosen cut-off frequency. These abnormal irregularities on the filtered FRF shape curves indicate the location of the faulty sensor, due to the irregularity of FRF shapes introduced by the faulty piezoelectric element. The proposed sensor fault method is experimentally demonstrated on a clamped-clamped steel beam mounted with piezoelectric buzzer array. Two common piezoelectric sensor fault types including sensor breakage and debonding are evaluated. The experimental results indicate that the proposed method has great potential in the detection of the sensor fault for piezoelectric array as it is simple and does not require the FRF data of the healthy sensor array as a baseline.


2021 ◽  
pp. 147592172110332
Author(s):  
Mehrdad Ghyabi ◽  
Hamidreza Nemati ◽  
Ehsan Dehghan-Niri

In this article, the coverage area prediction of piezoelectric sensor network for detecting a specific type of under-surface crack in plate-like structures is addressed. In particular, this article proposes a simplified framework to estimate the coverage of any given sensor network arrangement when a critical defect is known. Based on numerical results from finite element methods (FEM), a simplified framework to estimate coverage area of any given network arrangement is developed. Using such a simplified framework, one can avoid time-consuming procedure of evaluating numerous FEM models in estimating sensor network coverage. Back-scatter fields of partial cracks are estimated using a proposed function, whose parameters are estimated from the results of a limited number of FEM simulations. The proposed function efficiently predicts the back-scattered field of any combination of transmitters and receivers for a given crack geometry. Superposition is used to estimate the coverage area of an arbitrary piezoelectric (e.g., PZT) sensor network. It is shown that the coverage area of a sensor network depends on both sensor network geometry and defect properties (e.g., crack inclination) and it is not necessarily a linear function of the number of sensors. Furthermore, it is shown that the network arrangement has an important effect on the geometry of the coverage area. Experimental results of a network of 14 PZTs in two clusters confirm the accuracy of the method.


2006 ◽  
Vol 321-323 ◽  
pp. 968-971
Author(s):  
Won Su Park ◽  
Sang Woo Choi ◽  
Joon Hyun Lee ◽  
Kyeong Cheol Seo ◽  
Joon Hyung Byun

For improving quality of a carbon fiber reinforced composite material (CFRP) by preventing defects such as delamination and void, it should be inspected in fabrication process. Novel non-contacting evaluation technique is required because the transducer should be contacted on the CFRP in conventional ultrasonic technique during the non-destructive evaluation and these conventional contact techniques can not be applied in a novel fiber placement system. For the non-destructive evaluation of delamination in CFRP, various methods for the generation and reception of laser-generated ultrasound are applied using piezoelectric transducer, air-coupled transducer, wavelet transform technique etc. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Air-coupled transducer was tried to be adopted in reception of laser-generated guided wave generated by using linear slit array in order to generate high frequency guided wave with a frequency of 1.1 MHz. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer and linear slit array. Transmitted laser-generated ultrasonic wave was received on back-wall and its frequency was analyzed to establish inspecting technique to detect delamination by non-contact ultrasonic method. In a frequency spectrum analysis, intensity ratio of low frequency and center frequency was approvable parameter to detect delamination.


Sign in / Sign up

Export Citation Format

Share Document