scholarly journals Huffmanela sp. (Nematoda: Trichosomoididae: Huffmanelinae) encountered in the whitecheek shark (Carcharhinus dussumieri) in the Arabian Gulf

2021 ◽  
Vol 58 (3) ◽  
pp. 281-291
Author(s):  
M. M. Attia ◽  
M. M. Ibrahim ◽  
M. A. Mahmoud ◽  
M. N. S. Al-Sabi

Summary Veterinary inspection of fish caught at the western side of the Arabian Gulf off the shore of Saudi Arabia in 2017 revealed abnormal irregular zigzag black lines in the skins of 135 out of 1500 (prevalence = 9 %) whitecheek sharks (Carcharhinus dussumieri). These lesions have been noticed in the dorsal and ventral part of the head near the snout and around the eyes, as well as in the skin of the pectoral fins. The parasitological, pathological and ultramorphological aspects of the sampled fish were studied using a light microscope, as well as scanning and transmission electron microscopes. Trichosomoidid-type eggs identified as Huffmanela sp. were found in the superficial layer of the skin. The mature eggs containing larvae (n = 75) were ellipsoidal or spindle-shaped, smooth-shelled, amber-brown to dark brown or even black in colour. The width of the eggs ranged from 34 to 49μm with lengths ranging from 95 to 107μm. The polar plugs of the immature eggs were slightly protruding, whereas mature eggs had clearly protruding polar plugs. The width of the polar plugs ranged from 4.5 – 9.5μm. The shells of the eggs were smooth and there was a thin layer seen near the polar areas. The infected skin exhibited desquamated epithelium, with inflammatory cell aggregations and melanophores in the debris. The underlying musculatures of the skin were free from any eggs, but showed mild pathological changes, including congestion of blood vessels, haemorrhages and oedema. The prevalence of infection showed seasonality, peaking significantly in the spring (18.18 %), with comparable prevalence rates in winter and summer (9.43 % and 8.57 %, respectively). However, infections dropped significantly during the autumn months (3.75 %). It is believed that this is the first study reporting the presence of Huffmanela sp. in whitecheek sharks at El-Jubail Province, Saudi Arabia, Arabian Gulf.

Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Author(s):  
John C. Russ ◽  
Nicholas C. Barbi

The rapid growth of interest in attaching energy-dispersive x-ray analysis systems to transmission electron microscopes has centered largely on microanalysis of biological specimens. These are frequently either embedded in plastic or supported by an organic film, which is of great importance as regards stability under the beam since it provides thermal and electrical conductivity from the specimen to the grid.Unfortunately, the supporting medium also produces continuum x-radiation or Bremsstrahlung, which is added to the x-ray spectrum from the sample. It is not difficult to separate the characteristic peaks from the elements in the specimen from the total continuum background, but sometimes it is also necessary to separate the continuum due to the sample from that due to the support. For instance, it is possible to compute relative elemental concentrations in the sample, without standards, based on the relative net characteristic elemental intensities without regard to background; but to calculate absolute concentration, it is necessary to use the background signal itself as a measure of the total excited specimen mass.


Author(s):  
E. Zeitler ◽  
M. G. R. Thomson

In the formation of an image each small volume element of the object is correlated to an areal element in the image. The structure or detail of the object is represented by changes in intensity from element to element, and this variation of intensity (contrast) is determined by the interaction of the electrons with the specimen, and by the optical processing of the information-carrying electrons. Both conventional and scanning transmission electron microscopes form images which may be considered in this way, but the mechanism of image construction is very different in the two cases. Although the electron-object interaction is the same, the optical treatment differs.


Author(s):  
J.R. Parsons ◽  
C.W. Hoelke

The direct imaging of a crystal lattice has intrigued electron microscopists for many years. What is of interest, of course, is the way in which defects perturb their atomic regularity. There are problems, however, when one wishes to relate aperiodic image features to structural aspects of crystalline defects. If the defect is inclined to the foil plane and if, as is the case with present 100 kV transmission electron microscopes, the objective lens is not perfect, then terminating fringes and fringe bending seen in the image cannot be related in a simple way to lattice plane geometry in the specimen (1).The purpose of the present work was to devise an experimental test which could be used to confirm, or not, the existence of a one-to-one correspondence between lattice image and specimen structure over the desired range of specimen spacings. Through a study of computed images the following test emerged.


Author(s):  
A. Zangvil ◽  
L.J. Gauckler ◽  
G. Schneider ◽  
M. Rühle

The use of high temperature special ceramics which are usually complex materials based on oxides, nitrides, carbides and borides of silicon and aluminum, is critically dependent on their thermomechanical and other physical properties. The investigations of the phase diagrams, crystal structures and microstructural features are essential for better understanding of the macro-properties. Phase diagrams and crystal structures have been studied mainly by X-ray diffraction (XRD). Transmission electron microscopy (TEM) has contributed to this field to a very limited extent; it has been used more extensively in the study of microstructure, phase transformations and lattice defects. Often only TEM can give solutions to numerous problems in the above fields, since the various phases exist in extremely fine grains and subgrain structures; single crystals of appreciable size are often not available. Examples with some of our experimental results from two multicomponent systems are presented here. The standard ion thinning technique was used for the preparation of thin foil samples, which were then investigated with JEOL 200A and Siemens ELMISKOP 102 (for the lattice resolution work) electron microscopes.


Author(s):  
G. Lehmpfuhl ◽  
P. J. Smith

Specimens being observed with electron-beam instruments are subject to contamination, which is due to polymerization of hydrocarbon molecules by the beam. This effect becomes more important as the size of the beam is reduced. In convergent-beam studies with a beam diameter of 100 Å, contamination was observed to grow on samples at very high rates. Within a few seconds needles began forming under the beam on both the top and the underside of the sample, at growth rates of 400-500 Å/s, severely limiting the time available for observation. Such contamination could cause serious difficulty in examining a sample with the new scanning transmission electron microscopes, in which the beam is focused to a few angstroms.We have been able to reduce the rate of contamination buildup by a combination of methods: placing an anticontamination cold trap in the sample region, preheating the sample before observation, and irradiating the sample with a large beam before observing it with a small beam.


Author(s):  
John W. Andrew ◽  
F.P. Ottensmeyer ◽  
E. Martell

Energy selecting electron microscopes of the Castaing-Henry prism-mirror-prism design suffer from a loss of image and energy resolution with increasing field of view. These effects can be qualitatively understood by examining the focusing properties of the prism shown in Fig. 1. A cone of electrons emerges from the entrance lens crossover A and impinges on the planar face of the prism. The task of the prism is to focus these electrons to a point B at a focal distance f2 from the side of the prism. Electrons traveling in the plane of the diagram (i.e., the symmetry plane of the prism) are focused toward point B due to the different path lengths of different electron trajectories in the triangularly shaped magnetic field. This is referred to as horizontal focusing; the better this focusing effect the better the energy resolution of the spectrometer. Electrons in a plane perpendicular to the diagram and containing the central ray of the incident cone are focused toward B by the curved fringe field of the prism.


Author(s):  
Robert M. Fisher

By 1940, a half dozen or so commercial or home-built transmission electron microscopes were in use for studies of the ultrastructure of matter. These operated at 30-60 kV and most pioneering microscopists were preoccupied with their search for electron transparent substrates to support dispersions of particulates or bacteria for TEM examination and did not contemplate studies of bulk materials. Metallurgist H. Mahl and other physical scientists, accustomed to examining etched, deformed or machined specimens by reflected light in the optical microscope, were also highly motivated to capitalize on the superior resolution of the electron microscope. Mahl originated several methods of preparing thin oxide or lacquer impressions of surfaces that were transparent in his 50 kV TEM. The utility of replication was recognized immediately and many variations on the theme, including two-step negative-positive replicas, soon appeared. Intense development of replica techniques slowed after 1955 but important advances still occur. The availability of 100 kV instruments, advent of thin film methods for metals and ceramics and microtoming of thin sections for biological specimens largely eliminated any need to resort to replicas.


Author(s):  
J W Steeds

That the techniques of convergent beam electron diffraction (CBED) are now widely practised is evident, both from the way in which they feature in the sale of new transmission electron microscopes (TEMs) and from the frequency with which the results appear in the literature: new phases of high temperature superconductors is a case in point. The arrival of a new generation of TEMs operating with coherent sources at 200-300kV opens up a number of new possibilities.First, there is the possibility of quantitative work of very high accuracy. The small probe will essentially eliminate thickness or orientation averaging and this, together with efficient energy filtering by a doubly-dispersive electron energy loss spectrometer, will yield results of unsurpassed quality. The Bloch wave formulation of electron diffraction has proved itself an effective and efficient method of interpreting the data. The treatment of absorption in these calculations has recently been improved with the result that <100> HOLZ polarity determinations can now be performed on III-V and II-VI semiconductors.


Author(s):  
Martin Peckerar ◽  
Anastasios Tousimis

Solid state x-ray sensing systems have been used for many years in conjunction with scanning and transmission electron microscopes. Such systems conveniently provide users with elemental area maps and quantitative chemical analyses of samples. Improvements on these tools are currently sought in the following areas: sensitivity at longer and shorter x-ray wavelengths and minimization of noise-broadening of spectral lines. In this paper, we review basic limitations and recent advances in each of these areas. Throughout the review, we emphasize the systems nature of the problem. That is. limitations exist not only in the sensor elements but also in the preamplifier/amplifier chain and in the interfaces between these components.Solid state x-ray sensors usually function by way of incident photons creating electron-hole pairs in semiconductor material. This radiation-produced mobile charge is swept into external circuitry by electric fields in the semiconductor bulk.


Sign in / Sign up

Export Citation Format

Share Document