Diagnostic Accuracy of Clinical Testing for Superior Labral Anterior Posterior Lesions: A Systematic Review

Author(s):  
Wayne A. Dessaur
2013 ◽  
Vol 48 (6) ◽  
pp. 856-858 ◽  
Author(s):  
Michelle A. Sandrey

Reference/Citation: Calvert E, Chambers GK, Regan W, Hawkins RH, Leith JM. Special physical examination tests for superior labrum anterior-posterior shoulder injuries are clinically limited and invalid: a diagnostic systematic review. J Clin Epidemiol. 2009;62(5):558–563. Clinical Question: The systematic review focused on diagnostic accuracy studies to determine if evidence was sufficient to support the use of superior labrum anterior-posterior (SLAP) physical examination tests as valid and reliable. The primary question was whether there was sufficient evidence in the published literature to support the use of SLAP physical examination tests as valid and reliable diagnostic test procedures. Data Sources: Studies published in English were identified through database searches on MEDLINE, EMBASE, and the Cochrane database (1970–2004) using the search term SLAP lesions. The medical subject headings of arthroscopy, shoulder joint, and athletic injuries were combined with test or testing, physical examination, and sensitivity and specificity to locate additional sources. Other sources were identified by rereviewing the reference lists of included studies and review articles. Study Selection: Studies were eligible based on the following criteria: (1) published in English, (2) focused on the physical examination of SLAP lesions, and (3) presented original data. A study was excluded if the article was limited to a clinical description of 1 or more special tests without any research focus to provide clinical accuracy data or if it did not focus on the topic. Data Extraction: The abstracts that were located through the search strategies were reviewed, and potentially relevant abstracts were selected. Strict epidemiologic methods were used to obtain and collate all relevant studies; the authors developed a study questionnaire to record study name, year of publication, study design, sample size, and statistics. Validity of the diagnostic test study was determined by applying the 5 criteria proposed by Calvert et al. If the study met the inclusion and validity criteria, 95% confidence intervals were calculated for each sensitivity, specificity, and positive and negative likelihood ratio reported. No specific information was provided about the procedure if the reviewers disagreed on how the evaluation criteria were applied. Main Results: The specific search criteria led to the identification of 29 full-text articles. The studies were reviewed, and inclusion and exclusion criteria were applied. This resulted in 14 excluded studies and 15 eligible studies for analysis. Of the 15 eligible studies, 1 evaluated only a single physical examination test for a SLAP lesion or biceps tendon injury, and 10 studies evaluated 2 to 6 physical examination tests for a SLAP lesion or biceps tendon injury. Nine studies reported sensitivities and specificities greater than 75%, 4 had sensitivities less than 75%, 3 had specificities less than 75%, 1 did not report sensitivity, and 2 did not report specificities. When validity was assessed for those 15 papers, only 1 study that evaluated the biceps tendon met the 5 critical appraisal criteria of Calvert et al and calculated 95% confidence intervals. When the Speed and Yergason tests were each compared with the gold standard (arthroscopy), the confidence intervals for the positive and negative likelihood ratios spanned 1. This indicated that the test result is unlikely to change the odds of having or not having the condition, respectively. Conclusions: The literature currently used as a reference for teaching in medical schools and continuing education lacks the necessary validity to help rule in or out a SLAP lesion or biceps tendon involvement. Based on the results from the systematic review conducted by Calvert et al, no tests clinically diagnose a SLAP lesion. This is a cause for concern as magnetic resonance imaging or magnetic resonance arthrography, which are frequently used to assess a possible SLAP lesion, may also have diagnostic flaws and may be cost prohibitive. Performing arthroscopy on every patient to rule the condition in or out is unethical, especially if a SLAP lesion is not present. More rigorous validity studies should be conducted for SLAP lesion physical examination tests using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool or Standards for Reporting Diagnostic Accuracy (STARD) criteria.


2019 ◽  
Vol 11 (1) ◽  
Author(s):  
Daria Antipova ◽  
Leila Eadie ◽  
Ashish Stephen Macaden ◽  
Philip Wilson

Abstract Introduction A number of pre-hospital clinical assessment tools have been developed to triage subjects with acute stroke due to large vessel occlusion (LVO) to a specialised endovascular centre, but their false negative rates remain high leading to inappropriate and costly emergency transfers. Transcranial ultrasonography may represent a valuable pre-hospital tool for selecting patients with LVO who could benefit from rapid transfer to a dedicated centre. Methods Diagnostic accuracy of transcranial ultrasonography in acute stroke was subjected to systematic review. Medline, Embase, PubMed, Scopus, and The Cochrane Library were searched. Published articles reporting diagnostic accuracy of transcranial ultrasonography in comparison to a reference imaging method were selected. Studies reporting estimates of diagnostic accuracy were included in the meta-analysis. Results Twenty-seven published articles were selected for the systematic review. Transcranial Doppler findings, such as absent or diminished blood flow signal in a major cerebral artery and asymmetry index ≥ 21% were shown to be suggestive of LVO. It demonstrated sensitivity ranging from 68 to 100% and specificity of 78–99% for detecting acute steno-occlusive lesions. Area under the receiver operating characteristics curve was 0.91. Transcranial ultrasonography can also detect haemorrhagic foci, however, its application is largely restricted by lesion location. Conclusions Transcranial ultrasonography might potentially be used for the selection of subjects with acute LVO, to help streamline patient care and allow direct transfer to specialised endovascular centres. It can also assist in detecting haemorrhagic lesions in some cases, however, its applicability here is largely restricted. Additional research should optimize the scanning technique. Further work is required to demonstrate whether this diagnostic approach, possibly combined with clinical assessment, could be used at the pre-hospital stage to justify direct transfer to a regional thrombectomy centre in suitable cases.


Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 552
Author(s):  
Salam Awenat ◽  
Arnoldo Piccardo ◽  
Patricia Carvoeiras ◽  
Giovanni Signore ◽  
Luca Giovanella ◽  
...  

Background: The use of prostate-specific membrane antigen (PSMA)-targeted agents for staging prostate cancer (PCa) patients using positron emission tomography/computed tomography (PET/CT) is increasing worldwide. We performed a systematic review on the role of 18F-PSMA-1007 PET/CT in PCa staging to provide evidence-based data in this setting. Methods: A comprehensive computer literature search of PubMed/MEDLINE and Cochrane Library databases for studies using 18F-PSMA-1007 PET/CT in PCa staging was performed until 31 December 2020. Eligible articles were selected and relevant information was extracted from the original articles by two authors independently. Results: Eight articles (369 patients) evaluating the role of 18F-PSMA-1007 PET/CT in PCa staging were selected. These studies were quite heterogeneous, but, overall, they demonstrated a good diagnostic accuracy of 18F-PSMA-1007 PET/CT in detecting PCa lesions at staging. Overall, higher primary PCa aggressiveness was associated with higher 18F-PSMA-1007 uptake. When compared with other radiological and scintigraphic imaging methods, 18F-PSMA-1007 PET/CT had superior sensitivity in detecting metastatic disease and the highest inter-reader agreement. 18F-PSMA-1007 PET/CT showed similar results in terms of diagnostic accuracy for PCa staging compared with PET/CT with other PSMA-targeted tracers. Dual imaging with multi-parametric magnetic resonance imaging and 18F-PSMA-1007 PET/CT may improve staging of primary PCa. Notably, 18F-PSMA-1007-PET/CT may detect metastatic disease in a significant number of patients with negative standard imaging. Conclusions: 18F-PSMA-1007 PET/CT demonstrated a good accuracy in PCa staging, with similar results compared with other PSMA-targeted radiopharmaceuticals. This method could substitute bone scintigraphy and conventional abdominal imaging for PCa staging. Prospective multicentric studies are needed to confirm these findings.


BMJ Open ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. e038088
Author(s):  
Jacky Tu ◽  
Peter Gowdie ◽  
Julian Cassar ◽  
Simon Craig

BackgroundSeptic arthritis is an uncommon but potentially significant diagnosis to be considered when a child presents to the emergency department (ED) with non-traumatic limp. Our objective was to determine the diagnostic accuracy of clinical findings (history and examination) and investigation results (pathology tests and imaging) for the diagnosis of septic arthritis among children presenting with acute non-traumatic limp to the ED.MethodsSystematic review of the literature published between 1966 and June 2019 on MEDLINE and EMBASE databases. Studies were included if they evaluated children presenting with lower limb complaints and evaluated diagnostic performance of items from history, physical examination, laboratory testing or radiological examination. Data were independently extracted by two authors, and quality assessment was performed using the Quality Assessment Tool for Diagnostic Accuracy Studies 2 tool.Results18 studies were identified, and included 2672 children (560 with a final diagnosis of septic arthritis). There was substantial heterogeneity in inclusion criteria, study setting, definitions of specific variables and the gold standard used to confirm septic arthritis. Clinical and investigation findings were reported using varying definitions and cut-offs, and applied to differing study populations. Spectrum bias and poor-to-moderate study design quality limit their applicability to the ED setting.Single studies suggest that the presence of joint tenderness (n=189; positive likelihood ratio 11.4 (95% CI 5.9 to 22.0); negative likelihood ratio 0.2 (95% CI 0.0 to 1.2)) and joint effusion on ultrasound (n=127; positive likelihood ratio 8.4 (95% CI 4.1 to 17.1); negative likelihood ratio 0.2 (95% CI 0.1 to 0.3)) appear to be useful. Two promising clinical risk prediction tools were identified, however, their performance was notably lower when tested in external validation studies.DiscussionDifferentiating children with septic arthritis from non-emergent disorders of non-traumatic limp remains a key diagnostic challenge for emergency physicians. There is a need for prospectively derived and validated ED-based clinical risk prediction tools.


Sign in / Sign up

Export Citation Format

Share Document