scholarly journals Processing Errors in Complete Denture Fabrication - A Survey

2020 ◽  
Vol 11 (SPL3) ◽  
pp. 1371-1377
Author(s):  
Farhat Yaasmeen Sadique Basha ◽  
Venkatesh Kommi ◽  
Raj S S

There has been an increase in the incidence of complete edentulism among the elder patients. Complete dentures are the most common and preferred treatment of choice. Complete dentures help in masticatory function and restore the facial shape of the edentulous patients. Fabrication of the complete dentures is, therefore, a very important task for the clinician to ensure patient satisfaction. Errors may occur during the denture fabrication and these are called processing errors. It is a multifactorial process. The aim of the survey is to study the errors that occur during processing of a complete denture. It is a questionnaire based study conducted with a batch of 100 dental students. The questionnaire consisted of 16 questions focused on different fabrication techniques, timing, materials used, etc. by various students. The data collected was represented statistically and discussed. Dough technique was the most preferred method adopted by 39% of the students. Shorter curing cycles produced less defects, but majority of the students used longer cycles (41%). Most of them reported fractures (16%) and microporosities (11%) as defects. We can conclude that there are a few areas of error during the processing of dentures by the dental students. The incidence of these errors, however appears to be low. There is a scope for CAD/CAM complete dentures in the future to eliminate the possibilities of errors.

2014 ◽  
Vol 25 (5) ◽  
pp. 391-398 ◽  
Author(s):  
Danny Omar Mendoza Marin ◽  
Andressa Rosa Perin Leite ◽  
André Gustavo Paleari ◽  
Larissa Santana Rodriguez ◽  
Norberto Martins de Oliveira Junior ◽  
...  

The aim of the present study was to assess the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Fifty edentulous patients received a set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment protocols: Protocol 1- DA use during the first 15 days, followed by no DA for the next 15 days; Protocol 2- no DA during the first 15 days, followed by use of DA for the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to assess the patients´ satisfaction. A kinesiograph was used to record mandible movements and patterns of maxillary complete denture movement during chewing. The Wilcoxon test (α=0.05) and a paired sample t-test (α=0.05) were used to compare satisfaction levels and kinesiographic data, respectively. Use of DA improved the overall level of patient satisfaction (p<0.001). The kinesiographic recordings revealed a significant increase (1.7 mm) in vertical mandible movements (p<0.001) during chewing and a lower (0.3 mm) vertical intrusion of the maxillary complete dentures (p=0.002) during chewing after using the DA. Use of DA in complete denture wearers improved the patients´ satisfaction and altered mandible movements, with increases in vertical movements during chewing and less intrusion of maxillary complete dentures.


2020 ◽  
Vol 9 (2) ◽  
pp. 324 ◽  
Author(s):  
Corina Marilena Cristache ◽  
Eugenia Eftimie Totu ◽  
Gabriela Iorgulescu ◽  
Aida Pantazi ◽  
Dorel Dorobantu ◽  
...  

The present study aimed to assess the eighteen month follow-up patient-centered outcomes of a simple and predictable protocol for 3D-printed functional complete dentures manufactured using an improved poly(methyl methacrylate) (PMMA)–nanoTiO2. A detailed morphological and structural characterization of the PMMA–TiO2 nanocomposite, using SEM, EDX, XRD, and AFM, after 3D-printing procedure and post-wearing micro-CT, was also performed. Methods: A total of 35 fully edentulous patients were enrolled in this prospective study. A 0.4% TiO2-nanoparticle-reinforced PMMA composite with improved mechanical strength, morphologically and structurally characterized, was used according to an additive computer-aided design and computer-aided manufacturing (CAD/CAM) protocol for complete denture fabrication. The protocol proposed involved a three-step appointment process. Before denture insertion, 1 week, 12 month, and 18-month follow up patients were evaluated via the Visual Analogue Scale (VAS, 0–10) and Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT), with a higher score meaning poor quality of life. Results: A total of 45 complete denture sets were inserted. OHIP-EDENT scored significantly better after 18 months of denture wearing, 20.43 (±4.42) compared to 52.57 (±8.16) before treatment; mean VAS was improved for all parameters assessed. Conclusions: Within the limitations of this study, we can state that the proposed workflow with the improved material used is a viable treatment option for patients diagnosed with complete edentulism.


2012 ◽  
Vol 65 (3-4) ◽  
pp. 163-167
Author(s):  
Ljiljana Strajnic ◽  
Branka Miskovic

The aim of this study was to provide longitudinal evaluation of the changes after complete dentures therapy and the rate of residual ridge resorption through a six-year period of denture wearing. The authors presented the case of a 76-year-old patient, edentulous for twelve years, wearing complete dentures for six years, with the eugnat jaw relationship. Cephalometric radiograph was carried out in the process of new complete denture production, while the evaluation was carried out after six years. Cephalometric analysis was performed by using ?Dr. Ceph? computer software (FYI Technologies, GA, USA). After six years, the reduction of anterior total facial height was 5.5 mm and the anterior lower facial height was 5.5 mm, the vertical residual ridge reduction of the maxilla was 1.4 mm and the reduction of the mandible was 3mm. The study confirms the reliability and advantages of cephalometric analyses and reveals their application possibilities in prosthetic diagnostics and therapy, as well as in evaluation of rehabilitative results in edentulous patients and longitudinal analysis of changes on the orofacial complex tissues and intemaxillary relationships.


2021 ◽  
Vol 38 (SI-2) ◽  
pp. 92-97
Author(s):  
Emir YÜZBAŞIOĞLU ◽  
Yeşim ÖLÇER US ◽  
Gökhan ÖZDEMİR ◽  
Berkman ALBAYRAK

For decades, conventional complete dentures (CD) have been a promising treatment for edentulous patients. The introduction of digital technology in CD fabrication streamlines and simplifies the treatment process and offers new and specific applications for the completely edentulous patients. Computer-aided design/computer-assisted manufactured (CAD/CAM) CD protocols can improve efficiency and offer specific applications in specific situations to improve patient care, satisfaction, and convenience. The aim of this review is to assess and evaluate the clinical outcomes and complication of CAD/CAM fabricated CD systems and to provide information about currently available systems for dental practitioners.


2012 ◽  
Vol 69 (12) ◽  
pp. 1055-1060 ◽  
Author(s):  
Srdjan Postic

Background/Aim. Balanced occlusal arrangement of artificial teeth and balanced occlusion is a specific type of occlusion that preserves the stability of complete dentures. Balanced occlusion comprises realization of tooth contacts at the working side as well as at the balancing side, at the same time. The aim of this study was to assess the influence of balanced occlusal arrangement of artificial teeth on the decrease in reduction of edentulous alveolar ridge. Methods. A longitudinal study on 91 fully edentulous patients was conducted using their panoramic radiographs and parameters of vertical dimension of edentulous ridges. All the patients were clinically examined by the same and a qualified dental practitioner. Numerical values of parameters of vertical dimensions of edentulous ridges and lines were statistically processed and compared using the Student?s t-test. Results. Vertical dimensions and heights of edentulous ridges were different after comparison of parameters in complete denture wearers with balanced occlusion and complete denture wearers without bilaterally balanced occlusion, as well as between male and female edentulous patients. Statistically significant differences of heights were established in complete denture wearers? with a set of artificial teeth without balanced occlusion, at the baseline and 12 months after wearing of complete dentures. Conclusion. Balanced occlusion is a favored occlusal design in setting of artificial teeth in conventional complete dentures, which preserves edentulous ridge and influence the stability of dentures.


Author(s):  
Takayuki Ueda ◽  
Kaoru Sakurai ◽  
Takashi Koike ◽  
Syuutarou Noda ◽  
Koichiro Ogami

ABSTRACT Purpose The retention of complete dentures is frequently difficult in edentulous patients with a severely resorbed residual alveolar ridge. In such cases, implant overdentures having a stronger retention force are useful. Although there are various types of attachment systems for implant overdentures, they are frequently complicated. We are, therefore, developing a simple attachment system focusing on a soft lining material for the female connector. The purpose of this study was to evaluate the retention force of implant overdentures applying a soft lining material for the attachment. Materials and methods The models in which seven male and female connector pairs were used. As the control, a rubber O-ring attachment system, in which a rubber O-ring female was paired with a metal ball anchor (male), having a diameter of 1.7 or 2.2 mm. In the attachment system with a soft lining material, a female component was made up of soft lining material paired with a male having a diameter of 1.7, 2.2, 2.5, 2.7 or 3.0 mm. In measuring the retention force, the maximum force required to dislodge the male from the female was recorded by a digital force gauge. Results With the rubber O-ring, the retention force was 2.9 ± 0.2 N for the 1.7 mm male and 3.3 ± 0.3 N for the 2.2 mm male; these values were higher than the respective retention forces when using a soft lining material as the female and a male of the same diameter. However, with the female comprising soft lining material, the retention force exceeded 4 N for the 2.5, 2.7 and 3.0 mm males and was higher than the retention forces for the rubber O-ring. Conclusion The proposed attachment system with soft lining material for implant overdentures provides a clinically sufficient retention force when the diameter of the male exceeds 2.5 mm. How to cite this article Koike T, Ueda T, Noda S, Ogami K, Patil PG, Sakurai K. Development of New Attachment System with Soft Lining Material for Implant-retained Complete Denture. Int J Prosthodont Restor Dent 2013;3(1):21-24.


2019 ◽  
Vol 70 (2) ◽  
pp. 387-392 ◽  
Author(s):  
Corina Marilena Cristache ◽  
Eugenia Eftimie Totu ◽  
Alexandra Raluca Grosu ◽  
Oana Ene ◽  
Irina Adriana Beuran ◽  
...  

The aim of the present study was to evidence the improved behavior of our modified PMMA-TiO2 nanocomposite material used to obtain 3D printed complete dentures. A protocol for long-term rapid prototyping complete denture manufacturing using our nanocomposite material, completely characterized and the evaluation of the clinical performance and complications after eighteen months of continuous wearing was also described. Thirty-five fully edentulous patients were enrolled in this prospective clinical study and forty-five complete dentures (31 maxillary and 14 mandibular) have been obtained using an additive manufacturing technology. Due to the good performances of the nanocomposite material, no major functional complications for the obtained medical devices occurred and the clinical outcomes for the 3D printed dentures were favorable evaluated at eighteen months follow up.


2021 ◽  
Vol 15 (12) ◽  
pp. 3488-3490
Author(s):  
Amna Masood ◽  
Muhammad Shakeel Akram Khawaja ◽  
Nafeesa Abdullah ◽  
Noor Tarim Fahim

Objective: The aim of this study was to find out the role of depression in complete denture dissatisfaction and to determine frequencies of depression among the satisfied and dissatisfied patients. Study design: A cross sectional survey was carried out at Department of Prosthodontics, De’Montmorency College of Dentistry. Punjab Dental Hospital. The sample size was 80 edentulous patients having adequate maxillary and mandibular ridges. Methodology: The patients selected would be wearing complete dentures for the first time. All dentures were carefully designed. A socio-demographic form and depression rating questionnaire was filled by every participant involved in the study. After six months, satisfaction or dissatisfaction with the provided complete denture set was assessed through a separate questionnaire. The patients’ opinion concerning satisfaction with their dentures and depression was recorded and statistical analysis done. The results showed that 36.25% depressed versus 63.75% non-depressed. 28.75% were dissatisfied versus 71.25% satisfied. Conclusion: It was concluded that depression played a significant role in decreasing the satisfaction rating in first time denture wearers. Keywords: Depression, dissatisfaction, complete dentures,


Sign in / Sign up

Export Citation Format

Share Document