scholarly journals Traffic Intersections Noise Levels and Daily Noise Exposure in Chandrapur City, Central India

Author(s):  
Rahul K. Kamble

Noise level monitoring was carried out at nine important traffic intersections of the Chandrapur city to ascertain noise levels and daily noise exposure. A pre-calibrated mini sound level meter was used for noise measurement. Observations were recorded for 24 hours and noise level during the day, night and for 24-hours was computed. Maximum noise level during daytime was 84.27 dB(A) at Bangali camp square; whereas, minimum 79.23 dB(A) at Priyadarshani square. In case of nighttime maximum 85.90 dB(A) was at Warora naka square and minimum 70.06 dB(A) at the Jatpura gate. Minimum noise level during 24-hours was at Bagla square 84.34 dB(A) and maximum 91.14 dB(A) at Warora naka square. Noise level during day and night were above the Indian noise standard for the commercial area. The Bangali camp square was identified as the most ear-splitting square during daytime and Warora naka square at nighttime and for 24-hours also. Peak noise was recorded from 10.00 am to 11.00 am and 3.00 pm to 7.00 pm. Vehicular noise, horns, and improper road design contributed significantly to noise levels at traffic intersections. Daily noise exposure analysis by Health and Safety Executive, UK software revealed Bangali camp square and Ramnagar police station square’s daily noise exposure for 0.25 hour was maximum 70 LEP,d and minimum at Gandhi square and Bagla square 65 LEP,d. Noise levels indicated no immediate effect for hearing loss. Control measures for reduction of noise levels at traffic intersections have also been proposed.

2018 ◽  
Vol 7 (1) ◽  
pp. 1-13 ◽  
Author(s):  
Namrata R. Nimgade ◽  
R. K. Kamble

Assessment of occupational noise exposure of flour mill workers in Chandrapur city of central India was carried out during November 2015-January 2016. Total 62 flour mills were selected for this study comprising one, two and three grinding machines operating in the shop floor. The sound level meter was used to measure sound level at 50 cm and 3 meters from grinding machines at receiver’s position during operation. Noise monitoring was also recorded when one, two and three machines were operating individually and simultaneously. The results showed that noise levels when one grinding machine in operation in close proximity (50 cm) was in the range of 80-97 dB(A). Comparison of these observations with that of 3 meters distance; it was observed that noise levels got reduced and in the range of 70-77 dB(A). In the case of two machines in operation, it was in the range of 95-118 dB(A) at 50 cm distance and reduced to 75-95 dB(A) at 3 meters distance. This reduction in noise level was due to the propagation of noise in the ambient environment. Furthermore, daily noise exposure points, exposure points job per task and exposure points per hour were computed by using noise exposure calculator developed by Health and Safety Executive (HSE), United Kingdom. The computation from this calculator revealed that these attributes were directly depended upon noise levels in flour mills and duration of noise exposure. A positive linear Pearson’s correlation (p<0.01) was observed between noise level and exposure points per hour. Of the 65 flour mill workers surveyed, 70.76% reported a hearing problem, 23.07% headache at work and out of which 7.69% workers headache remains after completion of work also. Remedial measures to control noise exposure to flour mill workers such as ear plugs, ear muff, semi-insert are recommended.


Author(s):  
Chun-Yip Hon ◽  
Illia Tchernikov ◽  
Craig Fairclough ◽  
Alberto Behar

Excessive noise levels are a prevalent issue in food processing operations and, although there have been numerous studies on occupational noise, no single study has used a concurrent mixed-methods approach. Employing this study design allows for an understanding of the level of convergence (similarity) between measured noise levels and workers’ attitudes and perceptions towards noise. This, in turn, allows for the identification of potential challenges with respect to the implementation of hearing conservation efforts. In this study, spot noise measurements were collected using a sound level meter. One-on-one interviews were conducted with workers to determine attitudes and perceptions towards noise in their workplaces. Subsequently, the results of the noise measurements (quantitative data) were integrated with the survey responses (qualitative data) to identify convergence. The majority of the noise measurements were found to exceed 85 dBA—the criterion mandated by the local occupational health and safety legislation. Although all study participants felt that it was noisy in the workplace, a large proportion of respondents indicated that the noise was not bothersome. With workers’ perception being contradictory to the measured noise levels, it is a challenge to implement hearing conservation measures unless changes are made to raise the awareness of the risks associated with excessive noise exposure.


2008 ◽  
Vol 139 (2_suppl) ◽  
pp. P160-P160
Author(s):  
Angela P Black ◽  
James D Sidman

Objectives To demonstrate that neonatal ventilators produce high noise levels through bone conduction (BC) via endotracheal tubes, as well as air conduction (AC) from ambient noise. Methods A sound level meter was used to measure the noise levels 4 feet from the ventilator and in direct contact at the end of a balloon attached to the ETT to simulate the noise presented to the infant. 3 commonly used neonatal ventilators (Sensormedics 3100A, VIP Bird and Bunnell Jet) were examined. Results Noise levels were significantly higher (6 – 14 dB) at the end of the ETT than 4 ft from the ventilator for all ventilators studied. Conclusions Previous studies have shown high ambient noise levels in NICUs, but have failed to address the actual noise presented to the infant. ETT transmission of noise as a direct bone stimulus through the skull has been overlooked. This study has shown that high noise intensities are being presented not only as AC, but as BC to the infants though the ETT. This study demonstrates, therefore, that ear protection alone will not save these at-risk infants from hearing damage. More must be done to decrease noise exposure and develop quieter machines.


2018 ◽  
Vol 250 ◽  
pp. 02006
Author(s):  
Zaiton Haron ◽  
Darus Nadirah ◽  
Supandi Mohamad Afif ◽  
Yahya Khairulzan ◽  
Nordiana Mashros ◽  
...  

Transverse rumble strips (TRS) are commonly being installed to alert the drivers through sound and vibration effects. The sound produced affects the existing traffic noise level which caused noise annoyance to the nearby residents. This study aims to assess the traffic noise due to TRS at residential areas by determining the roadside noise levels, traffic and road characteristics and evaluating the relationship between these parameters. Middle overlapped (MO), middle layer overlapped (MLO) and raised rumbler (RR) TRS profiles with same thickness were selected. The measurements of roadside noise levels and skid resistance were conducted using sound level meter (SLM) and British pendulum tester (BPT) respectively. Traffic characteristics were evaluated using previous data measured using automatic traffic counter (ATC). In overall, MLO produced highest roadside noise levels with increase of 20.5dBA from baseline. Generally, the increase of roadside noise level due to TRS is strong with speed, weak to medium with skid resistance of TRS and no relationship with traffic volume. Based on three TRS profile types, MLO is not suitable to be installed on the roadways adjacent to the residential areas as the increase of roadside noise level is significant which is more than 5dBA compared to MO and RR.


2021 ◽  
Vol 7 (3) ◽  
pp. 560-574
Author(s):  
Mohamed N. Younes ◽  
Ali Z. Heikal ◽  
Akram S. Kotb ◽  
Haytham N. Zohny

The noise levels inside metro units are considered a significant problem that makes passengers suffer from severe damage, especially for those who use the metro periodically. This research evaluates the acoustic environment inside the metro car and studies factors affecting the noise levels inside metro units and developing models for estimate noise in the metro unit while moving between stations. Greater Cairo Metro (GCM) Line 1 has been selected as a case study. A sound level meter was used to measure the equivalent sound level in dBA and evaluate the noise inside metro units. The results indicate that the noise levels are unacceptable compared with the international noise exposure standards. The highest measured noise level inside metro units is 91.2 dBA. These unacceptable noise levels led to more investigation of factors that may affect noise levels inside metro units. Other data have been collected, such as the speed of the train and the track alignment details. The results showed that the noise increases with the increase of the train speed until the speed reaches a specific value, then it decreases depending on the maintenance status and the train type. In addition, the noise levels through curved underground tracks are higher than the levels along straight surface tracks by 18 dB(A). Doi: 10.28991/cej-2021-03091674 Full Text: PDF


2004 ◽  
Vol 31 (4) ◽  
pp. 533-538 ◽  
Author(s):  
Saad Abo-Qudais ◽  
Arwa Alhiary

The main objective of this study was to evaluate the variation in traffic equivalent noise levels as distance from the road intersection increases. To achieve this objective, traffic volume and equivalent noise level were monitored at 40 signalized intersections in Amman, the capital of Jordan. An integrated sound level meter (ISLM) was used to measure 1 min equivalent noise level along all approaches of the evaluated intersections. A total of 3326 noise measurements were performed. The collected data were analyzed to evaluate the variation of noise levels as distance from the intersection increases. The results indicated that equivalent noise levels were significantly affected by distance from the signal stop line. The equivalent noise levels at distances 50 and 100 m from the intersection were found to be 1.5 to 2.0 dB less than those at 0 m. While at 200, 250, and 300 m from the intersection, the monitored equivalent noise levels were found to be 3.8 to 4 dB higher than that at 0 m. At distances farther than 250 m, the measured equivalent noise levels tend to keep constant value of equivalent noise level as distance increased.Key words: noise, traffic, intersection, environment, pollution.


2021 ◽  
pp. 2571-2579
Author(s):  
Ahmed H. Ali ◽  
Mohammed M. Abed ◽  
Berivan H. Mahdi ◽  
Wassan D. Hussain ◽  
Aisar M. Mohaisen

     The aim of this study was to evaluate the effects of noise exposure in certain residential districts in Fallujah city. Twenty-nine stations were selected and divided into two groups; the first group was located 50 to 100 metres from the main streets (quiet areas), whilst the second was located directly on the main streets. Noise levels were measured at a rate of three readings per station for different time periods for approximately sixty days in the year 2020. Mean values were taken in both the morning and evening using a portable sound level meter (Auto range, RS-232). The highest noise level was measured at Alforkan station for the morning reading (83.8 dB) within the second group, while the lowest noise level was measured at Alshohada alawla district station for the morning reading (63.2 dB) within the first group. As for the results of the daily noise level in the evening, the highest daily average (79.4 dB) was measured at Jaish al Shabi street, while the lowest daily average (56.4 dB) was at Dor Alsekak district. The total average noise levels for the morning measurements for the first and second groups were 66.7 dB and 77.2 dB, respectively, whereas those for evening measurements were 65.3 dB and 71.7 dB, respectively. According to field measurements, the average values for the noise (traffic) for the first and second groups in the morning and afternoon exceeded 68 dB, which may cause people to feel very disturbed according to the WHO guidelines on exposure to external environmental noise. In general, all the results measured in this study are above the limits allowed both locally and internationally. This is due to certain erroneous practices in daily activities in addition to the irregular spread of electric generators and commercial activities as well as heavy traffic in the city.


Author(s):  
Aritrik Das ◽  

Introduction: In India, an area of not less than 100 metres around a hospital is considered a silence zone, with guidelines restricting noise levels at 50dBA during daytime and 40dBA during the night. Annoyance is a known effect of noise exposure. Objectives: To determine the feasibility of an extensive study on noise in the hospital, annoyance in staff due to hospital noise and its associated factors. Methods: Noise data was collected from 3 sites, using a Digital Integrating Sound Level Meter, LutronSL-4035SD(ISO-9001,CE,IEC1010) meeting IEC61672 standards. Stratified random sampling of staff was done on basis of noise exposure. A pre-designed, semi-structured questionnaire collected information on sociodemographic and work profile. Annoyance was measured using standardized general purpose noise reaction questionnaire (ISO-TS/ 15666). Data was analysed in SPSS. Result: Laeq ranged from 56dB in nephrology ward to 89.2dB at OPD atrium. Maximum noise level was 98.6dB in OPD atrium and 86.1dB in nephrology ward. Levels at night in ward were higher than during day time. 24 (53.3%) of the staff said their workplace is noisy, while 26(57.8%) were annoyed by workplace noise. Annoyance due to hospital noise was associated with age (p=0.003), duration of work in hospital per week (p=0.04), duration of work in current department (p=0.007), noise level (p=0.04) and workplace distance from arterial road (p=0.02). Conclusion: Hospital noise levels are higher than recommended levels for sensitive zones as per national guidelines and exceed levels inside wards as stipulated by WHO. More than half the study population were annoyed by workplace noise indicating need for interventions. A study throughout the hospital to study noise levels and annoyance among staff following similar methodology is feasible and necessary.


2013 ◽  
Vol 44 (2s) ◽  
Author(s):  
Pietro Catania ◽  
Mariangela Vallone

Noise in agriculture is one of the risk factors to be taken into account in the assessment of the health and safety of workers; in particular, it is known that the tractor is a source of high noise. The Italian Low Decree 81/2008 defined the requirements for assessing and managing noise risk identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This paper concerns the analysis of the noise risk arising from the use of a tracklaying tractor during field operations carried out in the vineyard. The objective of this study was to evaluate the noise level that comes close to the ear of the operator driving the tractor measuring the values of equivalent sound level (Leq(A)) and peak sound pressure (LCpk). We considered four options related to the same tractor coupled with the following tools to perform some farming operations: rototilling, chisel plough, flail mowers and vibro farmer. We considered three test conditions: T1 in flat (slope 0%), T2 uphill and T3 downhill (both 30% slope). The instrument used for the measurements is a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. Each survey lasted 2 minutes, with an interval of measurement equal to 0.5 s. The tests were performed in compliance with the standards ISO 9612 and ISO 9432. The results show that the measured sound levels exceed the limits allowed by the regulations in almost all the test conditions; values exceeding the threshold limit of 80 dB(A) were recorded coming up to a maximum value of 92.8 dB(A) for flail mowers in test T1. When limits imposed by the regulations are exceeded, the operator is obliged to wear the appropriate Personal Protective Equipment.


2015 ◽  
Vol 5 ◽  
pp. 69-74
Author(s):  
Lakshmi Nath Bhattarai

Undesirable sound for human hearing is called as noise. It was measured at the selected locations of silent, residential and commercial zones of Siddharthanagar Municipality by using Dick Smith Digital Sound Level Meter Q 1362 for ‘A’ weighting in day time at 9:00 AM to 6:00 PM in the month of November and December 2012. The result shows that at each location the Leq noise levels are above than the noise level standard prescribed by Government of Nepal and WHO. Maximum Leq of 81.9 dB(A) was observed at the Bus park of commercial area and minimum 54.5 dB(A) was observed at Medical College area of silent zone. In other places, the Leq lie in the range 56.2 dB(A) to 81.9 dB(A). The study showed that the places lying along highways have high level of noise which is due to bad condition of roads, vehicles and unnecessary use of horns  The Himalayan Physics Vol. 5, No. 5, Nov. 2014 Page: 69-74


Sign in / Sign up

Export Citation Format

Share Document