scholarly journals Analytical method validation of reversed phase HPLC for quantitative analysis of tartrazine and auramine o in powder drinks

Food Research ◽  
2020 ◽  
Vol 4 (6) ◽  
pp. 2037-2041
Author(s):  
A.D. Lestari ◽  
A. Rohman ◽  
S. Martono

This study was aimed to perform analytical method validation of high-performance liquid chromatography (HPLC) technique using photo-diode array detector for the simultaneous determination of Tartrazine (TAR) and Auramine O (AUO) in powder drink products. TAR and AUO were analysed using Waters Shield C18 column (250 mm x 4.6 mm i.d., 5 µm) using PDA detector at 300-650 nm. The mobile phase used was acetonitrileammonium acetate 19 mM (86:14 v/v) delivered isocratically at a flow rate of 1.2 mL/ min. The optimized HPLC condition was subjected to analytical method validation by assessing some performance characteristics as guided by International Conference on Harmonization (ICH). The method was linear over the studied concentration ranges with the coefficient of determination (R2 ) of 0.999 and 0.997 for TAR and AUR with % intercept less than 2%, respectively. The developed method was sensitive with a limit of detection value of 0.0325 μg/mL and 0.1052 μg/mL for TAR and AUO, respectively. The method is also accurate and precise as indicated with acceptable recovery values of 99.0- 100.7% for TAR and 102.1-106.5% for AUO with relative standard deviation (RSD) values lower than those required by Association of Official Analytical Chemists’ (AOAC). The developed method is simple and can be used for routine analysis of TAR and AUO for quality assurance purposes of powder drinks.

Author(s):  
Dilshad Ahmad ◽  
Faisal A. Al Meshaiti ◽  
Yazeed K. Al Anazi ◽  
Osama Al Owassil ◽  
Alaa Eldeen B. Yassin

Anastrozole, an aromatase inhibitor drug, is used for the treatment of breast cancer in pre- and postmenopausal women. Anastrozole’s incorporation into nanoparticulate carriers would enhance its therapeutic performance. To perceive the exact loaded amount of drug in nanocarriers, a valid analytical method is required. The reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated by using the C18 column, 150 × 4.6 mm, 5 µm particle size, in isocratic mobile phase composed of 50:50 V/V (volume/volume) acetonitrile–phosphate buffer (pH 3) flowing at a rate of 1.0 mL/min, and a diode array detector (DAD) set at λmax = 215 nm. The validation parameters such as linearity, accuracy, specificity, precision, and robustness have proven the accuracy of the method, with the relative standard deviation percentage (% RSD) values < 2. The limit of detection of the method was found equal to 0.0150 µg/mL, and the limit of quantitation was 0.0607 µg/mL. The percent recovery of sample was in the range of 98.04–99.25%. The method has the advantage of being rapid with a drug retention time of 2.767 min, specific in terms of resolution of peaks void of interference with any of the excipients, and high reproducibility. This makes it highly applicable for quality control purposes.


2021 ◽  
Vol 21 (5) ◽  
pp. 1196
Author(s):  
Ungku Amirul Arif Ungku Abdullah ◽  
Nor Suhaila Mohamad Hanapi ◽  
Wan Nazihah Wan Ibrahim ◽  
Nursyamsyila Mat Hadzir ◽  
Nurzaimah Zaini ◽  
...  

Existing methods used in tracing Tetracyclines' antibiotics (TCAs) residues which pose serious environmental problems, consume high amounts of organic solvents, are time-consuming, and are relatively expensive. A simple and effective magnetic solid-phase extraction (MSPE) based on reduced graphene oxide/magnetite (RGO/Fe3O4) nanocomposite sorbent was successfully developed for preconcentration and extraction of TCAs residues from water samples. The analytes were determined by high-performance liquid chromatography with a diode-array detector (HPLC-DAD). The synthesized nanocomposite was characterized using Fourier-transform infrared spectroscopy (FTIR), X-ray diffractometry (XRD), and field emission scanning electron microscopy (FESEM). Sample pH, amount of adsorbent, sample volume, extraction time, desorption time, and desorption solvent were evaluated and optimized. Under optimized conditions, the method demonstrated good linearity over the concentration range of 0.05–1.0 mg L–1 with the coefficient of determination (R2) ≥ 0.9978. Limit of detection (LOD) and limit of quantification (LOQ) were 0.006–0.011 mg L–1 and 0.019–0.036 mg L–1, respectively. The accuracy and precision of the developed method were proven by good analyte recovery (89.77–106.33%) and acceptable precision with relative standard deviation, RSD ≤ 5.54%. The results showed that magnetic solid RGO/Fe3O4 could be a suitable adsorbent in the preconcentration and extraction of TCAs in water samples.


Author(s):  
Valmir Gomes De Souza ◽  
FabrÍcio Havy Dantas De Andrade ◽  
Fabio Santos De Souza ◽  
Rui Oliveira Macedo

Objective: The Anadenanthera colubrina (Vell.) Brennan var. cebil is a medicinal plant that has been used for the treatment of many diseases in the northeastern region of Brazil. This plant contains secondary metabolites such as quercetin, a flavonoid that is known by its antioxidant and anti-inflammatory effects. The aim of this work is to propose the validation of an analytical method using high-performance liquid chromatography with diode array detector (HPLC-DAD) for the quantification of quercetin and standardization of the hydroalcoholic extract (HAE) of A. colubrina.Methods: The A. colubrina extracts were prepared by the maceration process with powdered leaves at 20% weight: volume (w/v) and a hydroalcoholic solution at 50% volume: volume (v/v) for 120 h at room temperature. After pretreatment of the hydroalcoholic extract, the quercetin marker was used for quantification and proceeded to the evaluation of validation parameters for the method using HPLC-DAD.Results: The analytical method proved to be specific. Linear over the range 1.4–26.6 µg/ml, regression analysis showed a good correlation coefficient (R2= 0.999); the limit of detection (LOD) and the limit of quantification (LOQ) were 0.27 and 0.81 μg/ml respectively. The relative standard deviation (RSD) did not exceed 2.5% for precision. The proposed method was validated with an average recovery of 92.5–97.5%.Conclusion: The method was validated using HPLC-DAD, allowing the quantification of quercetin in the standardisation process of extracts and quality control of the herbal drug containing A. colubrina Phyto complex.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.


Author(s):  
Kanan G Gamit ◽  
Niraj Y Vyas ◽  
Nishit D Patel ◽  
Manan A Raval

Objective: A study was aimed to estimate guggulsterone-Z (GZ) in Gokshuradi Guggulu (GG).Methods: An analytical method was developed and validated using Waters Alliance high-performance liquid chromatography system (Empower software), equipped with photodiode array detector. Separation was achieved using Phenomenex, C-18 (250 mm×4.6 mm, 5 μ) column. Mobile phase consisted of acetonitrile:water (70:30,v/v). Flow rate was set to 1 ml/min and detection was performed at 251 nm.Results and Discussion: Validation parameters such as linearity, precision, accuracy, limit of detection, limit of quantification, and robustness were performed. Amount of GZ was estimated using linearity equation.Conclusion: GG was found to contain 0.815±0.03 g% w/w GZ. Validated method may be used as one of the parameters to standardize the formulation.


2006 ◽  
Vol 89 (1) ◽  
pp. 1-7 ◽  
Author(s):  
Andrés Navarrete ◽  
Bharathi Avula ◽  
Vaishali C Joshi ◽  
Xiuhong Ji ◽  
Paul Hersh ◽  
...  

Abstract Amphiptherygium adstringens (Anacardiaceae/Julianaceae), local name cuachalalate, is used in folk medicine for the treatment of cholelithiasis, fevers, fresh wounds, hypercholesterolemia, gastritis, gastric ulcers, and cancer of the gastrointestinal tract. The development of column high-performance liquid chromatographyphotodiode array detector (LC-PDA) and high-performance thin-layer chromatography (HPTLC)densitometry methods for the determination of masticadienonic acid and 3-hydroxymasticadienonic acid in cuachalalate preparations is described in this paper. Good separation of the compounds could be achieved by both methods. Either might be preparable depending on the requirements. The LC separation was performed on a Phenomenex Synergi MAX-RP 80A reversed-phase column operated at 40C with detection at 215 nm. The plant materials were extracted with methanol by sonication. The triterpenes present in the plant material and commercial extracts were separated with an acetonitrilewater reagent alcohol isocratic system. The limit of detection was 0.10.2 g/mL. The relative standard deviation values for the determination of triterpenes in plant extracts were less than 1.00%. This is the first report of an analytical method developed for the quantitative analysis of triterpenes from Amphiptherygium adstringens by LC-PDA and HPTLC. The stem bark showed higher amounts of triterpenes, and low amounts in root and stem root. The microscopic description of the crude drug of cuachalalate was also provided.


2019 ◽  
Vol 57 (10) ◽  
pp. 931-938 ◽  
Author(s):  
Mohammad M Kamal ◽  
Sami Nazzal

Abstract Paclitaxel (PTX) and sulforaphane (SFN) are known anticancer molecules. Their activity was found to be potentiated when tested concurrently. Only recently, however, a novel SFN enabled PTX self-microemulsifying formulation (SMEDDS) was developed for their simultaneous delivery. This necessitated the development of an analytical method for the simultaneous detection and quantitation of PTX and SFN. In this study, a simple and sensitive isocratic high performance liquid chromatography-ultraviolet (HPLC-UV) analytical method was developed and validated per International Conference on Harmonization guidelines to satisfy this objective. Its application was demonstrated when quantifying the amount of PTX and SFN released from the SMEDDS in various dissolution media. The separation of the analytes was performed with the aid of a reversed phase C18 column at ambient temperature using a 60:40 mixture of acetonitrile and KH2PO4 buffer (pH 5.0) as the mobile phase. PTX and SFN peaks were detected at 202 nm with high resolution without interference from excipients. This method showed linearity within 2.5–100 μg/mL range with r2 &gt; 0.999. The limit of detection and lower limit of quantitation were 0.1638 and 0.4964 μg/mL for PTX and 0.4419 and 1.3389 μg/mL for SFN, respectively. A total of 98–101% of the injected samples was recovered with RSD of 0.06–0.68% indicating the suitability of the method for the simultaneous detection and quantitation of the molecules in dissolution media.


2009 ◽  
Vol 63 (6) ◽  
Author(s):  
Hong Yan ◽  
Pei Xu ◽  
Hai Huang ◽  
Juan Qiu

AbstractA pre-column derivatized high-performance liquid chromatographic (HPLC) method with ultraviolet-visible detection was developed to measure the concentrations of spectinomycin in fermentation broth. Derivatization reagents, 2,4-dinitrophenylhydrazine in acetonitrile (5 mg mL−1) and trifluoroacetic acid in acetonitrile (0.8 mol L−1), were added to an aliquot of the fermentation broth, and the mixture was incubated for 60 min at 70°C. The resulting derivative was separated from other compounds by isocratic elution in a reversed-phase column Zorbax SB-C18 (250 mm × 4.6 mm, 5 µm). Mobile phase consisted of acetonitrile, tetrahydrofuran, and water (φ r = 40: 35: 25) and the flow rate was 1.0 mL min−1. The detection wavelength was 415 nm. The standard curve for spectinomycin sulfate was linear with correlation coefficients of 0.9997 in the range of 25 µg mL−1 to 600 µg mL−1. The relative standard deviation values ranged from 0.43 % to 2.18 % depending on the concentration of samples. The average recovery was 101.5 %. The limit of detection was 50 ng mL−1.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
J. Álvarez-Fuentes ◽  
L. Martín-Banderas ◽  
I. Muñoz-Rubio ◽  
M. A. Holgado ◽  
M. Fernández-Arévalo

A simple, fast, and reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for determining of a cannabinoid derivate, which displays potent antihyperalgesic activity, 1-naphthalenyl[4-(pentyloxy)-1-naphthalenyl]methanone (CB13) into PLGA nanoparticles. Separation was achieved in a C18 column using a mobile phase consisting of two solvents: solvent A, consisting of acetonitrile : water : acetic acid (75 : 23.7 : 1.3 v/v), and solvent B, consisting of acetonitrile. An isocratic method (70 : 30 v/v), with a flow rate of 1.000 mL/min, and a diode array detector were used. The developed method was precise, accurate, and linear over the concentration range of analysis with a limit of detection and a limit of quantification of 0.5 and 1.25 μg/mL, respectively. The developed method was applied to the analysis of CB13 in nanoparticles samples obtained by three different procedures (SEV, FF, and NPP) in terms of encapsulation efficiency and drug release. Nanoparticles size and size distribution were also evaluated founding that NPP method presented the most lowest particle sizes with narrow-size distribution (≈320 nm) and slightly negative zeta potential (≈−25 mV) which presumes a suitable procedure for the synthesis of PLGA-CB13 nanoparticles for oral administration.


2018 ◽  
Vol 10 (1) ◽  
pp. 248
Author(s):  
Baitha Palanggatan Maggadani ◽  
Harmita . ◽  
Maizura Isfadhila

Objective: The aim of this study was to produce a selective, accurate, and faster high-performance liquid chromatography (HPLC) analytical methodfor benzalkonium chloride and glutaraldehyde in disinfectants using ultraviolet (UV)-visible detection.Methods: Glutaraldehyde has no chromophore, so it was first derivatized using 2,4 dinitro phenylhydrazine. Acetonitrile:water (75:25) was used asthe mobile phase for glutaraldehyde and acetonitrile-acetate pH 4 (75:25) for benzalkonium chloride, both at a flow rate of 1.2 mL/min. The optimizedassay was validated with respect to accuracy, precision, linearity, selectivity, limit of quantitation (LOQ), and limit of detection (LOD).Results: The method was linear for benzalkonium chloride, with correlation coefficient of 0.9995, LOD of 14.55 ppm, and LOQ of 48.51 ppm. Thecorrelation coefficient for glutaraldehyde was 0.9995, with LOD of 0.49 ppm and LOQ of 1.64 ppm. Accuracy was between 98% and 102%, andprecision was below 2% for both the tests.Conclusion: The HPLC analytical method for benzalkonium chloride and glutaraldehyde in disinfectants using UV-visible detection in this researchwas successful to produce a selective, accurate, and faster method.