Determination of the permittivity of materials in a volume resonator with allowance for the surface roughness

2021 ◽  
Vol 87 (5) ◽  
pp. 43-46
Author(s):  
V. P. Krylov

The accuracy of determining the permittivity of the material depends on the thickness of the intermediate layer with variable dielectric characteristics formed on the surface of the sample upon manufacturing. We present the results of studying the influence of the surface roughness of the test sample on the accuracy of determining the permittivity using the resonator method. An algorithm for calculating the permittivity in a volumetric cylindrical resonator is proposed, taking into account the roughness value and the residual gap. Using the matrix method for calculating the wave transmitted through the plate, a model for determination of the dielectric permittivity of a multilayer sample using a measuring resonator is developed. The results obtained can be used to improve the accuracy of the permittivity determination in a volume resonator when testing the samples with a roughness exceeding the required standard.

2004 ◽  
Vol 59 (9) ◽  
pp. 621-622 ◽  
Author(s):  
Fatih Ucun ◽  
Vesile Gūçlü

The force constants of the internal coordinates of nonlinear XY2 molecules in the gas-phase were calculated by using the GF matrix method. The matrix solution was carried out by means a computer program built relative to the Newton-Raphson method and the calculations were listed in a table. The force constants of some molecules in the liquidand solid- phase were also found and compared with these ones, and it was seen that the force constants for more condensed phase are lower as in an agreement with having its lower frequency.


1993 ◽  
Vol 292 (2) ◽  
pp. 351-360 ◽  
Author(s):  
S Thomas ◽  
D A Fell

A computer program (MetaCon) is described for the evaluation of flux control, concentration control and branch-point distribution control coefficients of a metabolic pathway. Requiring only the reaction scheme as input, the program produces algebraic expressions for the control coefficients in terms of elasticity coefficients, metabolite concentrations and pathway fluxes. Any of these variables can be substituted by numeric or simple algebraic expressions; the expressions will then be automatically rearranged in terms of the remaining unknown variables. When all variables have been substituted, numeric values will be obtained for the control coefficients. The program is a computerized implementation of the matrix method for the determination of control coefficients. The features of MetaCon are compared with those of other programs available to workers in Metabolic Control Analysis. Potential benefits of, and methods of using, MetaCon are discussed. The mathematical background and validity of the matrix method rules are discussed, and the algorithm used by MetaCon is described. The matrix method is shown to be a specific case of a previously described general formalism for calculating control coefficients.


2005 ◽  
Vol 60 (3) ◽  
pp. 183-186 ◽  
Author(s):  
Vesile Güçlü ◽  
Fatih Ucun

The force constants of the internal coordinates of planar XY3 and tetrahedral XY4 molecules were calculated using the GF matrix method. The matrix solutions were carried out by means of a computer program built relative to the Newton-Raphson method, and the calculations were listed in tables. For tetrahedral XY4 molecules having the same Y atom it was found that the force constants decrease with the increasing mass of the X atom, and this was attributed to the slowing of the molecule with increasing mass of the centre X atom.


Polyhedron ◽  
1987 ◽  
Vol 6 (9) ◽  
pp. 1717-1719 ◽  
Author(s):  
Éder Tadeu Gomes Cavalheiro ◽  
Ana Maria De Guzzi Plepis ◽  
Gilberto Orivaldo Chierice ◽  
Eduardo F.A. Neves

2007 ◽  
Vol 61 (1) ◽  
pp. 18-22
Author(s):  
Goran Tadic ◽  
Branko Pejovic ◽  
Miladin Gligoric ◽  
Vladan Micic

The problem of calculating stoichiometric coefficients in a chemical equation can be solved by standard methods and the method of multidimensional vector space, but good knowledge of vector algebra is required. In this paper, the authors proposed a matrix method and other treatment of the problem was given as the authors' own interpretation. A matrix was formed in the form of base using all the elements which take place in a chemical reaction, after which the matrixes of all the chemical compounds were determined based on numerical indexes and element symbols. This approach enables the setting of a principal matrix equation based on a mathematical approach. The solutions of this matrix equation are the desired stoichiometric coefficients that form a balanced equation. A new approach to tabular solving is presented. This method, compared to existing standard methods, is faster, simpler, and more effective, especially for complex chemical equations. The method was tasted on examples from inorganic chemistry and metallurgy.


2000 ◽  
Vol 43 (1) ◽  
pp. 63-68 ◽  
Author(s):  
R.J. Martin-Palma ◽  
J.M. Martinez-Duart ◽  
A. Macleod

2005 ◽  
Vol 60 (11-12) ◽  
pp. 819-822 ◽  
Author(s):  
Fatih Ucun ◽  
M. Gökhan Şengül

The force constants of the internal coordinates of octahedral XY6 molecules and complex ions were calculated by using the GF matrix method. The matrix solutions were found by means of a computer program using the Newton-Raphson method. From the calculations it has been observed that the bond stretch force constants of octahedral XF6 molecules and XY6 complex ions having the same centre X atom decrease with the increasing molar mass of the centre X atom for the former and the ligand Y atom for the latter, respectively. This was attributed to the slowing down of the molecule with increasing molar mass of the molecule as the whole. In addition we have concluded that the difference of squares of the vibration frequencies ν1 and ν2 of octahedral XY6 complex ions decreases with the increasing mass of the Y atom since the interaction force constant of these ions decreases with the increasing mass.


Author(s):  
H.J. Dudek

The chemical inhomogenities in modern materials such as fibers, phases and inclusions, often have diameters in the region of one micrometer. Using electron microbeam analysis for the determination of the element concentrations one has to know the smallest possible diameter of such regions for a given accuracy of the quantitative analysis.In th is paper the correction procedure for the quantitative electron microbeam analysis is extended to a spacial problem to determine the smallest possible measurements of a cylindrical particle P of high D (depth resolution) and diameter L (lateral resolution) embeded in a matrix M and which has to be analysed quantitative with the accuracy q. The mathematical accounts lead to the following form of the characteristic x-ray intens ity of the element i of a particle P embeded in the matrix M in relation to the intensity of a standard S


Author(s):  
Dr. G. Kaemof

A mixture of polycarbonate (PC) and styrene-acrylonitrile-copolymer (SAN) represents a very good example for the efficiency of electron microscopic investigations concerning the determination of optimum production procedures for high grade product properties.The following parameters have been varied:components of charge (PC : SAN 50 : 50, 60 : 40, 70 : 30), kind of compounding machine (single screw extruder, twin screw extruder, discontinuous kneader), mass-temperature (lowest and highest possible temperature).The transmission electron microscopic investigations (TEM) were carried out on ultra thin sections, the PC-phase of which was selectively etched by triethylamine.The phase transition (matrix to disperse phase) does not occur - as might be expected - at a PC to SAN ratio of 50 : 50, but at a ratio of 65 : 35. Our results show that the matrix is preferably formed by the components with the lower melting viscosity (in this special case SAN), even at concentrations of less than 50 %.