Radiolysis of transformer oil in presence of trichlorbenzen and nano-γ-Al2O3

2021 ◽  
Vol 2 ◽  
pp. 80-85
Author(s):  
Z. I. Iskenderova ◽  

In this work, a comparative study of the kinetics of changes in the pH indicator, the formation of H2O2 and CO2 depending on the absorbed dose at the radiolysis of TCB containing transformer oil in the presence and without nano-γ-Al2O3 under the action of γ radiation was carried out. During radiolysis of both systems (TСB + transformer oil and TСB + transformer oil + 0.1 g of nano-γ-Al2O3), the radiation-chemical yield of CO2 decreases with an increase in the initial concentration of TCB, although at the presence of nano-particles, the values of the radiation-chemical riels of CO2 become less. Unlike CO2, the radiation-chemical yields of H2O2 increase with an increase in the initial concentration of TCB, but their values are less in the presence of nano-γ-Al2O3. The results obtained are explained by the reactions of active particles, radiolysis of the main components of transformer oil, such as hydrogen atoms and hydrocarbon radicals with TCB and dissolved oxygen molecules. In addition, there is a transfer of electronic excitation energy from alkane and cycloalkane molecules to aromatic hydrocarbon molecules. The effect of nano-γ-Al2O3 on the radiolysis of the mixture is discussed on the basis of the reaction of electron and hole centers with the molecules of the components of the irradiated mixture.

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Nehad Magdy ◽  
Sameh Gafar

Purpose The purpose of this research paper is to study a comparison between two dosimetry systems, both of them based on basic violet dye (BV). Design/methodology/approach The first system depends on (BV) (incorporating polyvinyl alcohol) as a thin-film dosimeter. The second system also relies on (BV) as a solution dosimeter, which is more sensitive to gamma rays. The two prepared film/solutions have a considerable signal that decreases upon irradiation and the strength of the signal decreases with increasing radiation dose. Findings The gamma ray absorbed dose for these dosimeters was found to be up to 35 kGy for films and 1 kGy for the liquid phase. All dosimetric characteristics as radiation chemical yield, additive substance, dose-response function, radiation sensitivity, also before and after-irradiation stability under various conditions were considered. Practical implications It is expected the vital role of gamma radiation on this dye in its two forms or two media. This reveals their wide applications in the field of gamma irradiation processing. Originality/value These two dosimetry systems which depend upon the same dye are safe to handle, inexpensive, available raw materials and can be applied in various dosimetry applications as mentioned above.


2019 ◽  
Vol 48 (6) ◽  
pp. 540-546 ◽  
Author(s):  
Sameh Mohamed Gafar ◽  
Nehad Magdy Abdel-Kader

Purpose The purpose of this paper is to study the effect of gamma-rays on murexide (Mx) dye and its possible use as radiation dosimeters in two different dosimetry systems. The first system depends on the Mx dye as a liquid dosimeter. The second dosimetry system depends also on the same dye but as in a gel form, which is more sensitive to gamma-rays. Design/methodology/approach The prepared Mx (solutions/gels) have a considerable two peaks at 324 and 521 nm that upon irradiation, the intensity of these peaks decreases with the increasing radiation dose. Findings The gamma-ray absorbed dose for these dosimeters was found to be up to 2 kGy for the solution samples and 40 Gy for the gels. Radiation chemical yield, dose response function, radiation sensitivity and before and after-irradiation stability under various conditions were discussed and studied. Practical implications It is expected that the radiolysis of the Mx dye can be used as radiation dosimeters in two different dosimetry systems; liquid and gel dosimeters. This can be applied in a wide range of gamma radiation practical industrial applications in water treatment, food irradiation dosimeters, radiotherapy and fresh food irradiation and seed production. Originality/value Both of the prepared Mx dyes, either as solutions or gel samples, can be facilely prepared from commercially, cheap, safe, available chemicals and suitable for useful applied Mx solutions and gels radiation dosimeters.


2018 ◽  
Vol 0 (0) ◽  
Author(s):  
Murtaza Sayed ◽  
Fazal Hadi ◽  
Javed Ali Khan ◽  
Noor S. Shah ◽  
Luqman Ali Shah ◽  
...  

Abstract In the present study, degradation of acetaminophen (ACT) aqueous solution was investigated up to an absorbed γ-irradiation dose of 1000 Gy. The effects of various additives on the degradation efficiency of ACT were also studied. The results showed that ACT degradation was increased with the increase of an absorbed dose. Based on spectrophotometric analysis, 82.5% degradation of the initial ACT concentration (9.98×10−5 M) was easily achieved at an absorbed dose of 1000 Gy. The decay of ACT followed pseudo-first order reaction kinetics at different initial concentrations. The radiation chemical yield (G-value) decreased with the increase of an absorbed dose, however at a specific absorbed dose G-values increased with the increase of ACT initial concentration. The addition of H2O2 in the range of 0.1–0.7% was effective for degradation of ACT. The degradation of ACT was inhibited in both acidic and basic solutions while maximium degradation effiency was acheived at nearly neautral solution pH, 7.6. The degradation process was markedly enhanced under oxidative conditions while strongly restrained under reductive conditions, which suggests the key role of oxidative radicals (˙OH) in the degradation of ACT.


2019 ◽  
pp. 191-195
Author(s):  
Z.I. Iskenderova

A comparative study of the radiolysis of used transformer oil and oil containing 1, 2, 4-trichlorbenzene (TCB) under the influence of gamma-radiation was carried out. Dependence of concentration of H2, H2O2, pH-indicator and IR-spectra of γ-irradiated samples from absorbed doses in the range of 4…136 kGy was studied. The pH-value dependence and concentration of hydrogen peroxide as a function of the absorbed dose is studied. Irradiation leads to increasing of acidity, related with dechlorination of TCB molecules. It is found that during the radiolysis of transformer oil containing TCB in the presence of dissolved oxygen, radiation-initiated oxidation of the oil takes place (formation of H2O2, CO2).


2017 ◽  
Vol 32 (2) ◽  
pp. 148-154 ◽  
Author(s):  
Moshira El-Kelany ◽  
Sameh Gafar

The present study involves a comparison between two dosimetry systems. The first system depends on victoria blue B (incorporating polyvinyl alcohol) as a thin-film dosimeter. The second system depends on the same dye as a liquid dosimeter, which is more sensitive to gamma rays. The prepared film/liquid has a considerable signal that increases upon irradiation and the intensity of the signal decrease with increasing radiation dose. The gamma ray absorbed dose for these dosimeters was found to be up to 25 kGy for the thin film and 700 Gy for the liquid form. Radiation chemical yield, additive substance, dose response function, radiation sensitivity, also before and after-irradiation stability under various conditions were discussed and studied.


Author(s):  
Zhanna B. Lyutova ◽  
◽  
Natalya A. Orekhova ◽  
Anastasia A. Yamshchikova ◽  
Igor V. Yudin ◽  
...  

To assess the possibility of using radiation purification of aqueous solutions from contained pharmacological preparations by spectrophotometry, high-performance liquid chromatography and chemical analysis, the effect of the absorbed dose of ionizing radiation on the concentration of analytes in solutions was studied. The values of the radiation-chemical yield of destruction of the investigated pharmaceutical preparations, the formation of peroxide products of radiolysis were determined, and the values of absorbed doses sufficient for the complete decomposition of the substances under consideration were calculated. It was shown that at initial concentrations of ketoprofen of 1,1•10-4 M and diclofenac of 0,5•10-4 M, the values of absorbed doses required for their complete decomposition are 2,4 kGy and 0,85 kGy, respectively. The obtained values indicate the possibility of using radiation technology for the purification of aqueous solutions from those pharmaceutical preparations. Further research can clarify the necessary doses for sufficient destruction of various groups of drugs in concentrations found in wastewater


2009 ◽  
Vol 44 (2) ◽  
pp. 211-213 ◽  
Author(s):  
Yutaka Mori ◽  
Toshiji Ikeda ◽  
Tomoya Yamauchi ◽  
Atsushi Sakamoto ◽  
Hiraku Chikada ◽  
...  

2015 ◽  
Vol 1084 ◽  
pp. 42-45
Author(s):  
Valentina Sokhoreva ◽  
Vladimir Golovkov ◽  
Natalya A. Dubrova ◽  
Dmitry Sidko

The experimental study of the kinetics of styrene monomer accumulation in polyvinylidene fluoride films with radiation-chemical grafting of styrene monomer is presented. It is proved that the degree of grafting depends on the absorbed dose of helium ions, temperature and composition of the grafting solution.


Sign in / Sign up

Export Citation Format

Share Document