scholarly journals The use of bio-carriers and zeolite in a lab-scale MBR for membrane fouling mitigation

2018 ◽  
Vol 21 (1) ◽  
pp. 58-63

<p>The Membrane Bio-Reactor (MBR) technology offers a series of environmentally-friendly advantages, such as high quality effluent, pathogens removal capacity and avoided use of chemicals for disinfection, allowing it to be regarded as an environmentally friendly technology, when applied for wastewater treatment. However, membrane fouling still remains a major drawback, preventing its widespread application for municipal or industrial wastewater treatment. The use of additives (i.e. adsorbents, bio-carriers etc.) is considered to be among the major strategies implemented for membrane fouling control over the last few years. The present work examines the influence of bio-carriers addition, as well as of zeolite powder on the reversible and irreversible membrane fouling of a lab-scale MBR. High-strength synthetic municipal wastewater (with BOD5 around 1000 mg/L) was fed as the substrate for the activated sludge process and a flat-sheet microfiltration membrane was operated for solids (biomass) - liquid separation at the flux of 17 L/m2h. The obtained results showed that the addition of zeolite contributed mainly to the alleviation of irreversible fouling, leaving the reversible fouling practically unaffected, while the addition of bio-carriers had quite the opposite effect. In addition, it was shown that the lab-scale MBR system operated successfully, treating a high-strength synthetic municipal wastewater, as high removals were observed in terms of both organics and especially of ammonium removal (over 98%).</p>

2019 ◽  
Vol 5 (4) ◽  
pp. 684-692 ◽  
Author(s):  
Yan Sun ◽  
Shanshan Gao ◽  
Jiayu Tian ◽  
Xiujuan Hao ◽  
Zhiquan Liu ◽  
...  

Air bubbling along the membrane improves water flux, alleviates the deposition of foulants and inhibits the formation of a fouling layer.


2020 ◽  
Vol 6 (10) ◽  
pp. 2641-2663
Author(s):  
Yisong Hu ◽  
Hui Cheng ◽  
Jiayuan Ji ◽  
Yu-You Li

Among the various anaerobic digestion technologies developed for wastewater treatment and resource recovery, the anaerobic membrane bioreactor (AnMBR) stands out as a viable alternative to traditional processes.


2003 ◽  
Vol 48 (1) ◽  
pp. 191-198 ◽  
Author(s):  
T.K. Chen ◽  
C.H. Ni ◽  
J.N. Chen ◽  
J. Lin

The membrane bioreactor (MBR) system has become more and more attractive in the field of wastewater treatment. It is particularly attractive in situations where long solids retention times are required, such as nitrifying bacteria, and physical retention critical to achieving more efficiency for biological degradation of pollutant. Although it is a new technology, the MBR process has been applied for industrial wastewater treatment for only the past decade. The opto-electronic industry, developed very fast over the past decade in the world, is high technology manufacturing. The treatment of the opto-electronic industrial wastewater containing a significant quantity of organic nitrogen compounds with a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N) is very difficult to meet the discharge limits. This research is mainly to discuss the treatment capacity of high-strength organic nitrogen wastewater, and to investigate the capabilities of the MBR process. A 5 m3/day capacity of MBR pilot plant consisted of anoxic, aerobic and membrane bioreactor was installed for evaluation. The operation was continued for 150 days. Over the whole experimental period, a satisfactory organic removal performance was achieved. The COD could be removed with an average of over 94.5%. For TOC and BOD5 items, the average removal efficiencies were 96.3 and 97.6%, respectively. The nitrification and denitrification was also successfully achieved. Furthermore, the effluent did not contain any suspended solids. Only a small concentration of ammonia nitrogen was found in the effluent. The stable effluent quality and satisfactory removal performance mentioned above were ensured by the efficient interception performance of the membrane device incorporated within the biological reactor. The MBR system shows promise as a means of treating very high organic nitrogen wastewater without dilution. The effluent of TKN, NOx-N and COD can fall below 20 mg/L, 30 mg/L and 50 mg/L.


2009 ◽  
Vol 3 (1) ◽  
pp. 8-16 ◽  
Author(s):  
Jian-Jun Qin ◽  
Boris Liberman ◽  
Kiran A. Kekre ◽  
Ado Gossan

Reverse osmosis (RO) has been widely applied in various water and wastewater treatment processes as a promising membrane technology. However, RO membrane fouling is a global issue, which limits it operating flux, decreases water production, increases power consumption and requires periodical membranes Cleaning-in-Place (CIP) procedure. This may result in low effectiveness, high cost and adds environmental issues related to the CIP solutions disposal. Forward osmosis (FO) or direct osmosis (DO) is the transport of water across a semi-permeable membrane from higher water chemical potential side to lower water chemical potential side, which phenomenon was observed in 1748. The engineered applications of FO/DO in membrane separation processes have been developed in food processing, wastewater treatment and seawater/brackish water desalination. In recent years, DO has been increasingly attractive for RO fouling control as it is highly efficient and environmentally friendly technique which is a new backwash technique via interval DO by intermittent injection of the high salinity solution without stoppage of high pressure pump or interruption of the operational process and allows keeping RO membrane continuously clean even in heavy bio-fouling conditions and operating RO membranes at high flux. This paper provides the state-of-the-art of the physical principles and applications of DO for RO fouling control as well as its strengths and limitations.


Membranes ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 231
Author(s):  
Yi Ding ◽  
Zhansheng Guo ◽  
Zhenlin Liang ◽  
Xuguang Hou ◽  
Zhipeng Li ◽  
...  

In this study, the characteristics of activated sludge flocs were investigated and their effects on the evolution of membrane fouling were considered in the anaerobic membrane bioreactors (AnMBR), which were operated at 25 and 35 °C for municipal wastewater treatment. It was found that the membrane fouling rate of the AnMBR at 25 °C was more severe than that at 35 °C. The membrane fouling trends were not consistent with the change in the concentration of soluble microbial product (SMP). The larger amount of SMP in the AnMBR at 35 °C did not induce more severe membrane fouling than that in the AnMBR at 25 °C. However, the polysaccharide and protein concentration of extracellular polymeric substance (EPS) was higher in the AnMBR at 25 °C in comparison with that in the AnMBR at 35 °C, and the protein/polysaccharide ratio of the EPS in the AnMBR at 25 °C was higher in contrast to that in the AnMBR at 35 °C. Meanwhile, the fouling tendencies measured for the AnMBRs could be related to the characteristics of loosely bound EPS and tightly bound EPS. The analysis of the activated sludge flocs characteristics indicated that a smaller sludge particle size and more fine flocs were observed at the AnMBR with 25 °C. Therefore, the membrane fouling potential in the AnMBR could be explained by the characteristics of activated sludge flocs.


Processes ◽  
2020 ◽  
Vol 8 (12) ◽  
pp. 1546
Author(s):  
Monika Vítězová ◽  
Anna Kohoutová ◽  
Tomáš Vítěz ◽  
Nikola Hanišáková ◽  
Ivan Kushkevych

Over the past decades, anaerobic biotechnology is commonly used for treating high-strength wastewaters from different industries. This biotechnology depends on interactions and co-operation between microorganisms in the anaerobic environment where many pollutants’ transformation to energy-rich biogas occurs. Properties of wastewater vary across industries and significantly affect microbiome composition in the anaerobic reactor. Methanogenic archaea play a crucial role during anaerobic wastewater treatment. The most abundant acetoclastic methanogens in the anaerobic reactors for industrial wastewater treatment are Methanosarcina sp. and Methanotrix sp. Hydrogenotrophic representatives of methanogens presented in the anaerobic reactors are characterized by a wide species diversity. Methanoculleus sp., Methanobacterium sp. and Methanospirillum sp. prevailed in this group. This work summarizes the relation of industrial wastewater composition and methanogen microbial communities present in different reactors treating these wastewaters.


Sign in / Sign up

Export Citation Format

Share Document