Quality indicators of the spontaneous fermentation starters of cereals flour during the lower-temperature conservation process

2018 ◽  
Vol 6 (11) ◽  
pp. 116-122
Author(s):  
Larysa Mikhonik ◽  
◽  
Inna Getman ◽  
Natalia Bela ◽  
Halyna Bogdan ◽  
...  
Author(s):  
Richard S. Thomas ◽  
Prabir K. Basu ◽  
Francis T. Jones

Silicon tetrachloride, used in industry for the production of highest purity silicon and silica, is customarily manufactured from silica-sand and charcoal.SiCl4 can also be made from rice hulls, which contain up to 20 percent silica and only traces of other mineral matter. Hulls, after carbonization, actually prove superior as a starting material since they react at lower temperature. This use of rice hulls may offer a new, profitable solution for a rice mill byproduct disposal problem.In studies of the reaction kinetics with carbonized hulls, conversion of SiO2 to SiCl4 was found to proceed within a few minutes to a constant, limited yield which depended reproducibly on the ambient temperature of the reactor. See Fig. 1. This suggested that physical or chemical heterogeneity of the silica in the hull structure might be involved.


2011 ◽  
Vol 49 (05) ◽  
Author(s):  
C Bannert ◽  
K Reinhart ◽  
D Dunkler ◽  
M Trauner ◽  
W Weiss ◽  
...  

2018 ◽  
Author(s):  
K Triantafyllou ◽  
S Karamaroudis ◽  
S Hariklia Vorri ◽  
P Gkolfakis ◽  
V Papadopoulos ◽  
...  

2019 ◽  
pp. 3-8
Author(s):  
N.Yu. Bobrovskaya ◽  
M.F. Danilov

The criteria of the coordinate measurements quality at pilot-experimental production based on contemporary methods of quality management system and traditional methods of the measurements quality in Metrology are considered. As an additional criterion for quality of measurements, their duration is proposed. Analyzing the problem of assessing the quality of measurements, the authors pay particular attention to the role of technological heredity in the analysis of the sources of uncertainty of coordinate measurements, including not only the process of manufacturing the part, but all stages of the development of design and technological documentation. Along with such criteria as the degree of confidence in the results of measurements; the accuracy, convergence, reproducibility and speed of the results must take into account the correctness of technical specification, and such characteristics of the shape of the geometric elements to be controlled, such as flatness, roundness, cylindrical. It is noted that one of the main methods to reduce the uncertainty of coordinate measurements is to reduce the uncertainty in the initial data and measurement conditions, as well as to increase the stability of the tasks due to the reasonable choice of the basic geometric elements (measuring bases) of the part. A prerequisite for obtaining reliable quality indicators is a quantitative assessment of the conditions and organization of the measurement process. To plan and normalize the time of measurements, the authors propose to use analytical formulas, on the basis of which it is possible to perform quantitative analysis and optimization of quality indicators, including the speed of measurements.


2020 ◽  
Vol 29 (12) ◽  
pp. 52-58
Author(s):  
E.P. Meleshkina ◽  
◽  
S.N. Kolomiets ◽  
A.S. Cheskidova ◽  
◽  
...  

Objectively and reliably determined indicators of rheological properties of the dough were identified using the alveograph device to create a system of classifications of wheat and flour from it for the intended purpose in the future. The analysis of the relationship of standardized quality indicators, as well as newly developed indicators for identifying them, differentiating the quality of wheat flour for the intended purpose, i.e. for finished products. To do this, we use mathematical statistics methods.


2019 ◽  
Vol 326 (1) ◽  
pp. 158-161
Author(s):  
G.M. Hasanova ◽  
◽  
Kh.N. Rustamov ◽  

TAPPI Journal ◽  
2015 ◽  
Vol 14 (9) ◽  
pp. 565-576 ◽  
Author(s):  
YUCHENG PENG ◽  
DOUGLAS J. GARDNER

Understanding the surface properties of cellulose materials is important for proper commercial applications. The effect of particle size, particle morphology, and hydroxyl number on the surface energy of three microcrystalline cellulose (MCC) preparations and one nanofibrillated cellulose (NFC) preparation were investigated using inverse gas chromatography at column temperatures ranging from 30ºC to 60ºC. The mean particle sizes for the three MCC samples and the NFC sample were 120.1, 62.3, 13.9, and 9.3 μm. The corresponding dispersion components of surface energy at 30°C were 55.7 ± 0.1, 59.7 ± 1.3, 71.7 ± 1.0, and 57.4 ± 0.3 mJ/m2. MCC samples are agglomerates of small individual cellulose particles. The different particle sizes and morphologies of the three MCC samples resulted in various hydroxyl numbers, which in turn affected their dispersion component of surface energy. Cellulose samples exhibiting a higher hydroxyl number have a higher dispersion component of surface energy. The dispersion component of surface energy of all the cellulose samples decreased linearly with increasing temperature. MCC samples with larger agglomerates had a lower temperature coefficient of dispersion component of surface energy.


TAPPI Journal ◽  
2009 ◽  
Vol 8 (3) ◽  
pp. 14-20 ◽  
Author(s):  
YUAN-SHING PERNG ◽  
EUGENE I-CHEN WANG ◽  
SHIH-TSUNG YU ◽  
AN-YI CHANG

Trends toward closure of white water recirculation loops in papermaking often lead to a need for system modifications. We conducted a pilot-scale study using pulsed electrocoagulation technology to treat the effluent of an old corrugated containerboard (OCC)-based paper mill in order to evaluate its treatment performance. The operating variables were a current density of 0–240 A/m2, a hydraulic retention time (HRT) of 8–16 min, and a coagulant (anionic polyacrylamide) dosage of 0–22 mg/L. Water quality indicators investigated were electrical con-ductivity, suspended solids (SS), chemical oxygen demand (COD), and true color. The results were encouraging. Under the operating conditions without coagulant addition, the highest removals for conductivity, SS, COD, and true color were 39.8%, 85.7%, 70.5%, and 97.1%, respectively (with an HRT of 16 min). The use of a coagulant enhanced the removal of both conductivity and COD. With an optimal dosage of 20 mg/L and a shortened HRT of 10 min, the highest removal achieved for the four water quality indicators were 37.7%, 88.7%, 74.2%, and 91.7%, respectively. The water qualities thus attained should be adequate to allow reuse of a substantial portion of the treated effluent as process water makeup in papermaking.


Sign in / Sign up

Export Citation Format

Share Document