scholarly journals Comparing the Dimensional Accuracy of Casts Obtained from Two Types of Silicone Impression Materials in Different Impression Techniques and Frequent Times of Cast Preparation

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Ali Hafezeqoran ◽  
Mahdi Rahbar ◽  
Roodabeh Koodaryan ◽  
Tina Molaei

Introduction. The dimensional accuracy of casts is essential in the quality of fixed prosthesis treatment, whereby the impression method is a very crucial factor affecting it. The aim of this in vitro study is to compare the dimensional accuracy of casts resulting from two types of silicone impression materials in different impression techniques and frequent times of cast preparation. Materials and Methods. A metal model was made from two prepared abutments, and 10 casts were prepared from each material technique (n = 40). The impressions were made by condensation and addition silicone (one-stage and two-stage impressions). The casts were made from same impressions 1 h, 24 h, and 14 days. The diameter, height, and the distance between two dies were recorded. Data were analyzed by repeated measure ANOVA (P value <0.05). Results. The dimensional accuracy of all four materials techniques of impression (diameter, height, and the distance between dies) was the same in different times of impression. Dimensional accuracy of the die diameter and distance between dies in one-stage (Speedex) condensation silicon and one-stage (Panasil) addition silicone did not differ significantly, and their one-stage method developed more accurate casts compared to the two-stage method of the same impression material. The height of the casts prepared from the one-stage method through Speedex and Panasil did not differ significantly from the two-stage method of the same impression material. Conclusion. One-stage condensation silicone and one-stage addition silicone material techniques offered the maximum dimensional accuracy in the obtained casts. The time of impression did not have any significant effect in the accuracy of any of the four impression material techniques.

2013 ◽  
Vol 14 (2) ◽  
pp. 265-268 ◽  
Author(s):  
Naveen S Yadav ◽  
Teerthesh Jain ◽  
Amrita Pandita ◽  
SMA Feroz ◽  
Pradeep LNU ◽  
...  

ABSTRACT Aim Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. Materials and methods In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. Results Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. Conclusion All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. Clinical significance In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions. How to cite this article Pandita A, Jain T, Yadav NS, Feroz SMA, Pradeep, Diwedi A. Evaluation and Comparison of Dimensional Accuracy of Newly Introduced Elastomeric Impression Material using 3D Laser Scanners: An in vitro Study. J Contemp Dent Pract 2013;14(2):265-268.


2014 ◽  
Vol 3 (2) ◽  
pp. 28-33
Author(s):  
Shakila Fatema ◽  
Sheikh Md Shahriar Quader ◽  
Mohammad Shamsuzzaman ◽  
Mirza Md Arifur Rahman ◽  
Nasima Khan

Background: To achieve accuracy and exact reproduction of prosthesis, choosing a perfect impression material is essential. Especially to make the prosthesis as accurately as possible, impression material should possess some essential properties, like; minimum dimensional changes, good flow ability and easy removal. Purpose: The aim of this study was to evaluate the accuracy and surface detail reproduction of Alginate and Addition Reaction Silicone as an impression materials. Method: This is an experimental in vitro study. In this study Impression by Alginate and Addition Reaction Silicone were made using a round stainless steel test block with three horizontal lines and two vertical lines. The horizontal lines were used for evaluating the surface detail reproduction, and vertical lines were provided for the dimensional accuracy. For dimensional accuracy the length of the middle horizontal line in between vertical lines and the distance between the top and bottom horizontal line was measured using travelling microscope. And for surface detail reproduction three horizontal line of one segment were observed under stereomicroscope. Result: According to study results Addition Reaction Silicone is better than Alginate regarding quality of impression. Conclusion: In comparison to Alginate, Addition Reaction Silicone might have better performance about accuracy and surface detail reproduction. DOI: http://dx.doi.org/10.3329/updcj.v3i2.17996 Update Dent. Coll. j: 2013; 3 (2): 28-33


2015 ◽  
Vol 12 (2) ◽  
pp. 111-117
Author(s):  
P K Parajuli ◽  
S George ◽  
V Shenoy

Background: Dual-arch impression technique allows the simultaneous recording of  tooth preparation, opposing anatomic tooth and maxillomandibular relationship. The  accuracy of reproduction of this easy and quick technique, however, has not been  studied in detail in past. Objective: To compare the accuracy of the impressions  made by using the same impression material in dual arch plastic trays, dual-arch  metal trays and acrylic resin custom trays. Methods: The dies obtained from the  addition silicone impressions made in dual-arch plastic trays, dual-arch metal trays  and full arch acrylic resin custom trays were compared for the dimensional accuracy  with the prepared typodont tooth as a control. Student’s paired t-test and unpaired  t-test were used for the data analyses using the Statistical Package for Social Studies  (SPSS) version 11.5. Results: The dies obtained from all the impression combinations  showed increased dimension (acrylic resin custom trays 9.4 mm±0.048, dual-arch  plastic trays 9.5 mm±0.035, dual-arch metal trays 9.41 mm±0.017) as compared to  the dimension of control (9.39 mm±0.007). Conclusion: All the tray-impression  material combinations showed variable accuracies. Full arch acrylic resin trays  resulted in greatest accuracy whereas dual-arch plastic trays the least accuracy.Health Renaissance 2014;12(2):  pp: 111-117


Blood ◽  
1952 ◽  
Vol 7 (7) ◽  
pp. 710-720 ◽  
Author(s):  
S. VAN CREVELD ◽  
M. M. P. PAULSSEN

Abstract Transfusions of heparinized plasma have a greater and more lasting effect on the coagulation time of hemophiliacs than transfusions of citrated plasma. Both in vitro and in vivo, heparinized plasma causes in hemophiliacs a far greater consumption of prothrombin as determined with the two-stage method than citrated plasma. In using the one-stage method no important differences in prothrombin activity are found after transfusions of heparinized and of citrated plasma respectively. This fact was thought to be connected with the more or less rapid appearance of an accelerator. Its a hemophiliac with a circulating anticoagulant, transfusions of heparinized plasma were unable to shorten the coagulation time to any important degree, nor did these transfusions cause an important decrease of serum prothrombin as determined by the two-stage method.


2021 ◽  
Vol 22 (2) ◽  
pp. 172-178
Author(s):  
Sunita Singh ◽  
Shabab A Khan ◽  
Nudrat Neyaz ◽  
Mishan Mohohar Jaiswal ◽  
Aditi S Tanwar ◽  
...  

1979 ◽  
Vol 42 (04) ◽  
pp. 1230-1239 ◽  
Author(s):  
I M Nilsson ◽  
T B L Kirkwood ◽  
T W Barrowcliffe

SummaryThe recovery and half-life of VIII: C in the plasma of severely haemophilic patients was measured by one-stage and two-stage assays after injection of two Factor VIII concentrates (Hemofil, Hyland and Fraction I-O, Kabi). Plasma volumes were measured with an Evans� Blue technique, and both concentrates and post-infusion samples were measured against the same plasma standard.There was a highly significant difference in recoveries estimated by the two assay methods. The one-stage assays gave the most consistent results, in that the average recovery was 100%, whereas the two-stage assays gave only about 80% of the value expected from in vitro assays. There was no difference in recoveries between the two concentrates.The two-stage assays gave a slightly shorter half-life than the one-stage assays, and the half-life of Hemofil was also shorter than that of Fraction I-O.


2014 ◽  
Vol 40 (2) ◽  
pp. 137-145 ◽  
Author(s):  
Malesh Pujari ◽  
Pooja Garg ◽  
D. R. Prithviraj

Movement of impression copings inside the impression material using a direct (open tray) impression technique during clinical and laboratory phases may cause inaccuracy in transferring the 3-dimensional spatial orientation of implants intraorally to the cast. Consequently, the prosthesis may require corrective procedures. This in vitro study evaluated the accuracy of 3 different impression techniques using polyether and vinyl polysiloxane (VPS) impression material to obtain a precise cast for multiple internal connection implants. A reference acrylic resin model with 4 internal connection implants was fabricated. Impressions of the reference model were made using 3 different techniques and 2 different impression materials. The study consisted of 24 specimens divided into 6 groups of 4 each. Impressions were poured with ADA type IV stone (Kalrock, Kalabhai Karson Pvt Ltd, Mumbai, India). All casts were evaluated for the positional accuracy (mm) of the implant replica heads using a profile projector. These measurements were compared to the measurements calculated on the reference resin model, which served as a control. Data were analyzed with 2-way analysis of variance (ANOVA) followed by Bonferroni multiple comparison procedures to evaluate group means. The results revealed significant difference for anterior implant distance between the 2 impression materials (P &lt; .01) and also among the 3 different techniques (P &lt; .05). The lowest mean variation was found with the polyether impression material and the splinted technique. For posterior implants, the results suggested no significant difference between the 2 impression materials (P ≥ .05). Although results were not statistically significant, the polyether impression material showed the lowest mean variation as compared to the VPS impression material. However, there was a significant difference among the 3 different techniques (P &lt; .05). Among the 3 different techniques, the lowest mean variation between 2 posterior implants was found in the splinted technique. Casts obtained from impression techniques using square impression copings splinted together with autopolymerizing acrylic resin prior to the impression procedure were more accurate than casts obtained from impressions with nonmodified implant impression copings and with airborne particle–abraded, adhesive-coated copings. Casts obtained from polyether impression material were more accurate than casts obtained from vinyl polysiloxane impression material.


2021 ◽  
pp. 28-30
Author(s):  
Ajay Balaji ◽  
Naveen .B.H ◽  
Kalavthi. S.D ◽  
arun Thomas Philip

Impression making is the primary step in the process of fabrication of prosthetic restoration. Dimensional stability, Surface detail reproduction, and compatibility with gypsum products is an essential prerequisite for a successful restoration. Clinically, the accuracy of impressions depends on two major aspects: 1) Ability to ow and adapt intimately to the relevant surfaces while making the impression, and 2) the wetting of the polymerized impression material by the gypsum. The purpose of this study is to evaluate and compare the surface detail reproduction of BD Impress and Nexus Medodent impression material. The results showed signicant difference in surface detail between the two thermoplastic impression materials with p-value <0.05. It was observed that comparison of mean scores obtained by BD Impress and Nexus Medodent impression material are 2.7556 and 2.2222 respectively. The materials with minimum mean score value is considered as the material with good surface detail reproduction. Thus one can conclude that Nexus Medodent thermoplastic material has the good surface detail reproduction compared to BD Impress thermoplastic material.