scholarly journals DEVELOPMENT OF HINGE ISOLATED REINFORCED CONCRETE MEMBERS WITH LAP SPLICE SYSTEM

Author(s):  
Hisahiro HIRAISHI ◽  
Munenori YAMADA ◽  
Ryohei SAITO
2019 ◽  
Vol 35 (2) ◽  
pp. 1023-1043 ◽  
Author(s):  
Danilo Tarquini ◽  
João P. Almeida ◽  
Katrin Beyer

This data paper presents the quasi-static uniaxial cyclic tests of 24 reinforced concrete members, of which 22 feature lap splices and 2 are reference units with continuous reinforcement. The objective of the experimental program is to investigate the influence of lap splice length ( ls), confining reinforcement, and loading history on the behavior of lap splices. Particular attention is placed on the measurement of local deformation quantities, such as lap splice strains and rebar-concrete slip. Details of the geometry and reinforcement layout of the specimens as well as the employed test setup, instrumentation, and loading protocols are provided. The global behavior of the test units, including the observed crack pattern and failure modes, are discussed. The organization of the experimental data, which are made available for public use under DOI: 10.5281/zenodo.1205887, is outlined in detail.


2012 ◽  
Vol 455-456 ◽  
pp. 1079-1083
Author(s):  
Wei Jun Yang ◽  
Hong Jia Huang ◽  
Wen Yu Jiang ◽  
Yi Bin Peng

Shantou atmospheric salt-fog environment is simulated with the comprehensive salt spray test chamber. By using reinforced concrete short beams under different water-cement radio, different corrosion time, the inclined section degradation rules of the corrosive reinforced concrete members are researched for establishing shear capacity of short beam formulas in salt-fog environment.


2010 ◽  
Vol 163-167 ◽  
pp. 1574-1577 ◽  
Author(s):  
Tong Feng Zhao ◽  
Hong Nan Li ◽  
Jia Huan Yu

Moment-deformation curves of square steel tube filled with steel reinforced concrete subjected to bending load were simulated by the ABAQUS software. Calculated and experimental curves agreed well with each other. Through studying further the calculated member, the behavior of materials subjected to moment is given. Finally, flexural capacity formula of square steel tube filled with cross steel reinforced concrete is proposed.


Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3255 ◽  
Author(s):  
Fang Yuan ◽  
Mengcheng Chen

Fibre-reinforced polymer (FRP)-reinforced concrete members exhibit low ductility due to the linear-elastic behaviour of FRP materials. Concrete members reinforced by hybrid FRP–steel bars can improve strength and ductility simultaneously. In this study, the plastic hinge problem of hybrid FRP–steel reinforced concrete beams was numerically assessed through finite element analysis (FEA). Firstly, a finite element model was proposed to validate the numerical method by comparing the simulation results with the test results. Then, three plastic hinge regions—the rebar yielding zone, concrete crushing zone, and curvature localisation zone—of the hybrid reinforced concrete beams were analysed in detail. Finally, the effects of the main parameters, including the beam aspect ratio, concrete grade, steel yield strength, steel reinforcement ratio, steel hardening modulus, and FRP elastic modulus on the lengths of the three plastic zones, were systematically evaluated through parametric studies. It is determined that the hybrid reinforcement ratio exerts a significant effect on the plastic hinge lengths. The larger the hybrid reinforcement ratio, the larger is the extent of the rebar yielding zone and curvature localisation zone. It is also determined that the beam aspect ratio, concrete compressive strength, and steel hardening ratio exert significant positive effects on the length of the rebar yielding zone.


Sign in / Sign up

Export Citation Format

Share Document