scholarly journals Practicality of Wound Detection Using Smartphone Measure App

2021 ◽  
Author(s):  
Chun-I Fang ◽  
Tseng-Tzu Wu ◽  
Chen-Yi Chu ◽  
Yen-Chiao Lu

The record of the pressure sore with photo needs to be measurable. We compare the time consumption of wound assessment ruler and measure application of smartphone and the satisfaction of the users. The time needed is 20 and 35 seconds for the ruler and the application on average. But the satisfaction is better for application for its convenience, less infection, and the accuracy of measurements.

2000 ◽  
Vol 179 ◽  
pp. 205-208
Author(s):  
Pavel Ambrož ◽  
Alfred Schroll

AbstractPrecise measurements of heliographic position of solar filaments were used for determination of the proper motion of solar filaments on the time-scale of days. The filaments have a tendency to make a shaking or waving of the external structure and to make a general movement of whole filament body, coinciding with the transport of the magnetic flux in the photosphere. The velocity scatter of individual measured points is about one order higher than the accuracy of measurements.


Author(s):  
I.N. Yadhikov ◽  
S.K. Maksimov

Convergent beam electron diffraction (CBED) is widely used as a microanalysis tool. By the relative position of HOLZ-lines (Higher Order Laue Zone) in CBED-patterns one can determine the unit cell parameters with a high accuracy up to 0.1%. For this purpose, maps of HOLZ-lines are simulated with the help of a computer so that the best matching of maps with experimental CBED-pattern should be reached. In maps, HOLZ-lines are approximated, as a rule, by straight lines. The actual HOLZ-lines, however, are different from the straights. If we decrease accelerating voltage, the difference is increased and, thus, the accuracy of the unit cell parameters determination by the method becomes lower.To improve the accuracy of measurements it is necessary to give up the HOLZ-lines substitution by the straights. According to the kinematical theory a HOLZ-line is merely a fragment of ellipse arc described by the parametric equationwith arc corresponding to change of β parameter from -90° to +90°, wherevector, h - the distance between Laue zones, g - the value of the reciprocal lattice vector, g‖ - the value of the reciprocal lattice vector projection on zero Laue zone.


WCET Journal ◽  
2019 ◽  
Vol 39 (2) ◽  
pp. 9-18
Author(s):  
Wai Sze Ho ◽  
Wai Kuen Lee ◽  
Ka Kay Chan ◽  
Choi Ching Fong

Objectives The aim of this study was to retrospectively review the effectiveness of negative pressure wound therapy (NPWT) in sternal wound healing with the use of the validated Bates-Jensen Wound Assessment Tool (BWAT), and explore the role of NPWT over sternal wounds and future treatment pathways. Methods Data was gathered from patients' medical records and the institution's database clinical management system. Seventeen subjects, who had undergone cardiothoracic surgeries and subsequently consulted the wound care team in one year were reviewed. Fourteen of them were included in the analysis. Healing improvement of each sternal wound under continuous NPWT and continuous conventional dressings was studied. In total, 23 continuous NPWT and 13 conventional dressing episodes were analysed with the BWAT. Results Among conventional dressing episodes, sternal wound improvement was 2.5–3% over 10 days to 3.5 weeks, whereas 4–5% sternal healing was achieved in 5 days to 2 weeks with sternal wire presence. Better healing at 11% in 1 week by conventional dressing was attained after sternal wire removal. In NPWT episodes, 8–29%, 13–24%, and 15–46% of healing was observed in 2 weeks, 3.5 to 5 weeks and 6 to 7 weeks, respectively. Only 39% wound healing was acquired at the 13th week of NPWT in one subject. With sternal wire present, 6%–29% wound healing progress was achieved by NPWT in 1–4 weeks, and 16–23% wound improvement in 2 to 4.5 weeks by NWPT after further surgical debridement. After sternal wire removal, 6–34% sternal wound healing occurred by continuous NPWT for 1–2 weeks, and maximum healing at 46% after 2.5 weeks of NPWT were observed. Conclusions Better wound healing was achieved in the NPWT group in comparison to conventional dressings alone. However, suboptimal sternal wound healing by NPWT alone was observed. Removal of sternal wire may improve the effectiveness of NPWT. Successful tertiary closure after NPWT among subjects supports the important bridging role of NPWT in sternal wound healing. Factors causing stagnant sternal wound healing by NPWT alone are discussed.


WCET Journal ◽  
2019 ◽  
pp. 18-22
Author(s):  
Hiske Smart ◽  
Eman Al Al Jahmi ◽  
Ebrahim Buhiji ◽  
Sally-Anne Smart

Industrial infrared thermometry devices are large and, despite being less expensive than the current gold standard Exergen Dermatemp medical infrared thermometer, are still not affordable enough to ensure unrestricted and consistent use of this assessment modality in regular wound-related day-to-day practice. An increased skin surface temperature differentiation of 3°F associated with a wound has a positive predictive ability to detect deep or surrounding wound infection. This study hypothesised that inexpensive, pen- or pocket-sized, no-touch surface infrared thermometry devices will be equal in ability to detect a 3oF increased skin temperature compared to the Exergen Dermatemp infrared device and be reliable in the hands of any wound assessor. The odds of the control and other thermometers to detect a 3oF temperature difference, irrespective of the raters, were achieved in all five of the mini thermometers tested, with a correct temperature difference prediction that occurred in 90.933% of the times (odds determined 9/10). As a result of this study mini, no-touch infrared thermometry, to detect a 3oF temperature difference in wound assessment to determine tendency, could be implemented into primary health care clinics, rural clinics, day-to-day hospital practice and standard outpatients departments at a small financial cost, regardless of which thermometer is put to use.


2020 ◽  
pp. 52-58 ◽  
Author(s):  
A. A. Eryomenko ◽  
N. V. Rostunova ◽  
S. A. Budagyan ◽  
V. V. Stets

The experience of clinical testing of the personal telemedicine system ‘Obereg’ for remote monitoring of patients at the intensive care units of leading Russian clinics is described. The high quality of communication with the remote receiving devices of doctors, the accuracy of measurements, resistance to interference from various hospital equipment and the absence of its own impact on such equipment were confirmed. There are significant advantages compared to stationary patient monitors, in particular, for intra and out-of-hospital transportation of patients.


2020 ◽  
Vol 25 (5) ◽  
pp. 465-474
Author(s):  
V.O. Zhilinskiy ◽  
◽  
D.S. Pecheritsa ◽  
L.G. Gagarina ◽  
◽  
...  

The Global Navigation Satellite System has a huge impact on both the public and private sectors, including the social-economic development, it has many applications and is an integral part of many domains. The application of the satellite navigation systems remains the most relevant in the field of transport, including land, air and maritime transport. The GLONASS system consists of three segments and the operation of the entire system depends on functioning of each component, but primarily, the accuracy of measurements depends on the basis forming of the control segment and management, responsible for forming ephemeris-time information. In the work, the influence of ephemeris-time information on the accuracy of solving the navigation problem by the signals of the GLONASS satellite navigation system has been analyzed. The influence of both ephemeris information and the frequency information, and of the time corrections has been individually studied. The accuracy of the ephemeris-time information is especially important when solving the navigation problem by highly precise positioning method. For the analysis the following scenarios of the navigation problem solving have been formed: using high-precision and broadcast ephemeris-time information, a combination of broadcast (high-precision) ephemeris-time information, and high-precision (broadcast) satellite clock offsets and two scenarios with simulation of the calculation of the relative correction to the radio signal carrier frequency. Based on the study results it has been concluded that the contribution of the frequency-time corrections to the error of location determination is of the greatest importance and a huge impact on the error location, while the errors of the ephemeris information are insignificant


2020 ◽  
Vol 86 (7) ◽  
pp. 39-44
Author(s):  
K. V. Gogolinsky ◽  
A. E. Ivkin ◽  
V. V. Alekhnovich ◽  
A. Yu. Vasiliev ◽  
A. E. Tyurnina ◽  
...  

Thickness is one of the key indicators characterizing the quality and functional properties of coatings. Various indirect methods (electromagnetic, radiation, optical) most often used in practice to measure thickness are based on the functional dependence of a particular physical parameter of the system «base – coating» on the coating thickness. The sensitivity of these procedures to the certain properties of coatings imposes the main restriction to the accuracy of measurements. Therefore, the development and implementation of the approaches based on direct measurements of geometric parameters of the coating appears expedient. These methods often belong to the class of «destructive» and, in addition to measuring instruments, require the use of special equipment. To ensure the uniformity of measurements in the laboratory or technological control, these methods are isolated as a separate procedure (method) and must undergo metrological certification in accordance with GOST R 8.563–2009. We present implementation, metrological certification and practical application of the method for measuring thickness of coatings by crater-grinding method. The principles of technical implementation of test equipment, measurement procedure and calculation formulas are described. The results of evaluating the accuracy indicators of the proposed procedure by calculation and experimental methods are presented. In both cases, the relative error did not exceed 6%. The applicability of the developed technique is shown for a wide range of coating materials (from soft metals to superhard ceramics) of different thickness (with from units to hundreds of micrometers). Apart from the goals of process control and outgoing inspection, the method can be recommended as a reference measurement procedure for calibration of measures and adjusting samples for various types of thickness gauges.


2020 ◽  
Vol 2 (3) ◽  
pp. 01-03
Author(s):  
Ravi Chittoria

Pressure ulcer or pressure sore is one of the complications seen in bedridden patients. Management of these ulcers is often challenging. But there is no well-established method that accelerates the wound healing rate. Various adjunctive methods are used for wound bed preparation before definitive reconstruction plan is made. Here we describe our experience in the role of insulin therapy as an adjunct in the management of pressure sores.


2020 ◽  
Vol 17 (5) ◽  
pp. 354-364
Author(s):  
Mohammad Mahmoudi Goumari ◽  
Ibrahim Farhani ◽  
Navid Nezafat ◽  
Shirin Mahmoodi

Infectious diseases have caused historical pandemics in the world. Three strategies, including sanitation programs, antimicrobial drugs, and vaccines are considered for the prevention and treatment of infectious diseases. Today, some infectious diseases cause millions of mortalities universally. Due to the emergence of antibiotic-resistant pathogens, as well as some limitations of traditional vaccines, focusing on novel strategies is essential. Multi-Epitope Vaccines (MEVs), as a novel strategy, have been designed based on immunoinformatics methods; epitope prediction by authentic servers, attachment of epitopes using proper linkers, physicochemical, immunological and structural evaluation by bioinformatics tools that are basic stages in MEVs designing. Advantages such as cost-effective, high safety, less time consumption in designing, the application of natural adjuvants, and satisfactory preclinical evaluation outstand MEVs than other types of vaccines. Therefore, MEVs are promising vaccines against resistant diseases such as lower respiratory infection and diarrhea.


Sign in / Sign up

Export Citation Format

Share Document