scholarly journals HAZARDS OF STANDARD HEAT-EXCHANGE EQUIPMENT IMPLEMENTATION IN CHEMICAL TECHNOLOGY WITHOUT CONSIDERING THE PROCESS SPECIFIC CHARACTER

Author(s):  
K. O. Goncharuk ◽  
D. S. Kornilova ◽  
D. S. Yakovlev ◽  
N. N. Prokhorenko

Standard equipment is a considerable part of modern equipment of chemical plants. In particular, standard heat exchangers are widespread. Possible deviations in the operation of heat exchangers at plants from the preset parameters of their operation can lead to deterioration of the operation of the whole technological system. For this reason an attempt is made in the article to suggest a hypothesis explaining what can lead to disfunction in the operation of heat exchangers. The authors use a method of calculating technological reliability to study the operability of a vertical shell-and-tube heat exchanger. First, the size of the heat transfer surface of the vertical heat exchanger is calculated for specific conditions of work, and a standard device is chosen. Then a method of calculating the technological reliability of the calculated and standard heat exchangers is applied. An operating problem is solved on the assumption that external impacts on the heat transfer process are not fixed, but varied and are within their acceptable intervals. After comparing the probability of the workability of the calculated heat exchanger and of the chosen standard apparatus, a conclusion is made about the expediency of using the standard heat exchanger.

2020 ◽  
Vol 6 (6) ◽  
pp. 157-166
Author(s):  
F. He ◽  
A. Makeev

The progress made in recent years in the field of reinforced heat transfer technology of shell and tube heat exchangers in China and abroad is reviewed. The energy-saving means and results of improving the heat transfer efficiency of shell and tube heat exchangers are introduced from the experimental research and numerical simulation respectively, and the future research of shell and tube heat exchangers to strengthen the heat transfer technology is also foreseen.


2016 ◽  
Vol 37 (4) ◽  
pp. 137-159 ◽  
Author(s):  
Rafał Andrzejczyk ◽  
Tomasz Muszyński

Abstract The shell and coil heat exchangers are commonly used in heating, ventilation, nuclear industry, process plant, heat recovery and air conditioning systems. This type of recuperators benefits from simple construction, the low value of pressure drops and high heat transfer. In helical coil, centrifugal force is acting on the moving fluid due to the curvature of the tube results in the development. It has been long recognized that the heat transfer in the helical tube is much better than in the straight ones because of the occurrence of secondary flow in planes normal to the main flow inside the helical structure. Helical tubes show good performance in heat transfer enhancement, while the uniform curvature of spiral structure is inconvenient in pipe installation in heat exchangers. Authors have presented their own construction of shell and tube heat exchanger with intensified heat transfer. The purpose of this article is to assess the influence of the surface modification over the performance coefficient and effectiveness. The experiments have been performed for the steady-state heat transfer. Experimental data points were gathered for both laminar and turbulent flow, both for co current- and countercurrent flow arrangement. To find optimal heat transfer intensification on the shell-side authors applied the number of transfer units analysis.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1762 ◽  
Author(s):  
Zhe Wang ◽  
Fenghui Han ◽  
Yulong Ji ◽  
Wenhua Li

A marine seawater source heat pump is based on the relatively stable temperature of seawater, and uses it as the system’s cold and heat source to provide the ship with the necessary cold and heat energy. This technology is one of the important solutions to reduce ship energy consumption. Therefore, in this paper, the heat exchanger in the CO2 heat pump system with graphene nano-fluid refrigerant is experimentally studied, and the influence of related factors on its heat transfer enhancement performance is analyzed. First, the paper describes the transformation of the heat pump system experimental bench, the preparation of six different mass concentrations (0~1 wt.%) of graphene nanofluid and its thermophysical properties. Secondly, this paper defines graphene nanofluids as beneficiary fluids, the heat exchanger gains cold fluid heat exergy increase, and the consumption of hot fluid heat is heat exergy decrease. Based on the heat transfer efficiency and exergy efficiency of the heat exchanger, an exergy transfer model was established for a seawater source of tube heat exchanger. Finally, the article carried out a test of enhanced heat transfer of heat exchangers with different concentrations of graphene nanofluid refrigerants under simulated seawater constant temperature conditions and analyzed the test results using energy and an exergy transfer model. The results show that the enhanced heat transfer effect brought by the low concentration (0~0.1 wt.%) of graphene nanofluid is greater than the effect of its viscosity on the performance and has a good exergy transfer effectiveness. When the concentration of graphene nanofluid is too high, the resistance caused by the increase in viscosity will exceed the enhanced heat transfer gain brought by the nanofluid, which results in a significant decrease in the exergy transfer effectiveness.


Author(s):  
M. Izadi ◽  
D. K. Aidun ◽  
P. Marzocca ◽  
H. Lee

The effect of geometrical features on the air-side heat transfer and friction characteristics of an industrial plain fin-and-tube heat exchanger is investigated by 3-D numerical modeling and simulations. The heat exchanger has been designed and employed as an intercooler in a gas power plant and is a large-size compact heat exchanger. Most of the available design correlations developed so far for plain fin–and–tube heat exchangers have been prepared for small-size exchangers and none of them fits completely to the current heat exchanger regarding the geometrical limitations of correlations. It is shown that neglecting these limitations and applying improper correlations may generate considerable amount of error in the design of such a large-size heat exchanger. The geometry required for numerical modeling is produced by Gambit® software and the boundary conditions are defined regarding the real operating conditions. Then, three-dimensional simulations based on the SIMPLE algorithm in laminar flow regime are performed by FLUENT™ code. The effect of fin pitch, tube pitch, and tube diameter on the thermo-hydraulic behavior of the heat exchanger is studied. Some variations in the design of the heat exchanger are suggested for optimization purposes. It is finally concluded that the current numerical model is a powerful tool to design and optimize of large-size plain fin-and-tube heat exchangers with acceptable accuracy.


1966 ◽  
Vol 88 (2) ◽  
pp. 179-186 ◽  
Author(s):  
Franz J. Schulenberg

Finned circular tubes have been used exclusively in air-cooled heat exchangers built for the American petroleum and chemical industries. In Europe, however, other tube geometries, in particular, finned elliptical tubes, have been used with great success. In this paper, the theory of the finned elliptical tube and its application in air-cooled heat exchangers are discussed. Finned circular and elliptical tubes are compared; it is shown that the developed heat transfer surface alone is not a sufficient criterion for predicting the performance of an air-cooled fin-tube heat exchanger.


Author(s):  
Rong Yu ◽  
Andrew D. Sommers ◽  
Nicole C. Okamoto ◽  
Koushik Upadhyayula

In this study, we have explored the effectiveness of heat exchangers constructed using anisotropic, micro-patterned aluminum fins to more completely drain the condensate that forms on the heat transfer surface during normal operation with the aim of improving the thermal-hydraulic performance of the heat exchanger. This study presents and critically evaluates the efficacy of full-scale heat exchangers constructed from these micro-grooved surfaces by measuring dry/wet air-side pressure drop and dry/wet air-side heat transfer data. The new fin surface design was shown to decrease the core pressure drop of the heat exchanger during wet operation from 9.3% to 52.7%. Furthermore, these prototype fin surfaces were shown to have a negligible effect on the heat transfer coefficient under both dry and wet conditions while at the same time reducing the wet airside pressure drop thereby decreasing fan power consumption. That is to say, this novel fin surface design has shown the ability, through improved condensate management, to enhance the thermal-hydraulic performance of plain-fin-and-tube heat exchangers used in air-conditioning applications. This paper also presents data pertaining to the durability of the alkyl silane coating.


2006 ◽  
Vol 129 (9) ◽  
pp. 1256-1267 ◽  
Author(s):  
Worachest Pirompugd ◽  
Chi-Chuan Wang ◽  
Somchai Wongwises

This study proposes a new method, namely the “fully wet and fully dry tiny circular fin method,” for analyzing the heat and mass transfer characteristics of plain fin-and-tube heat exchangers under dehumidifying conditions. The present method is developed from the tube-by-tube method proposed in the previous study by the same authors. The analysis of the fin-and-tube heat exchangers is carried out by dividing the heat exchanger into many tiny segments. A tiny segment will be assumed with fully wet or fully dry conditions. This method is capable of handling the plain fin-and-tube heat exchanger under fully wet and partially wet conditions. The heat and mass transfer characteristics are presented in dimensionless terms. The ratio of the heat transfer characteristic to mass transfer characteristic is also studied. Based on the reduced results, it is found that the heat transfer and mass transfer characteristics are insensitive to changes in fin spacing. The influence of the inlet relative humidity on the heat transfer characteristic is rather small. For one and two row configurations, a considerable increase of the mass transfer characteristic is encountered when partially wet conditions take place. The heat transfer characteristic is about the same in fully wet and partially wet conditions provided that the number of tube rows is equal to or greater than four. Correlations are proposed to describe the heat and mass characteristics for the present plain fin configuration.


2012 ◽  
Vol 560-561 ◽  
pp. 156-160
Author(s):  
Lin Ping Lu ◽  
Liang Ying

The experiments on heat transfer coefficient, pressure drop and thermal stress were done to heat exchangers with corrugated tubes and staight tubes. By analyising and comparing the heat transfer coeffient, pressure drop in tube side and shell side and axial force and stress, some conclusions can be conducted that the corrugated tube heat exchanger has better heat transfer coeffient, higher pressure drop and much lower stress caused by temperatur difference, also, it has obvious advantages under the circumstance of low Reynolds number and high temperature difference.


Author(s):  
Majid Amidpour ◽  
Abazar Vahdat Azad

In this paper, the new approach of Constructal theory has been employed to design shell and tube heat exchangers. Constructal theory is a new method for optimal design in engineering applications. The purpose of this paper is optimization of shell and tube heat exchangers by reduction of total cost of the exchanger using the constructal theory. The total cost of the heat exchanger is the sum of operational costs and capital costs. The overall heat transfer coefficient of the shell and tube heat exchanger is increased by the use of constructal theory. Therefore, the capital cost required for making the heat transfer surface is reduced. Moreover, the operational energy costs involving pumping in order to overcome frictional pressure loss are minimized in this method. Genetic algorithm is used to optimize the objective function which is a mathematical model for the cost of the shell and tube heat exchanger and is based on constructal theory. The results of this research represent more than 50% reduction in costs of the heat exchanger.


Sign in / Sign up

Export Citation Format

Share Document