scholarly journals Investigating the impacts of asynchronous torque affecting to the transient stability in multi-machine power system

2014 ◽  
Vol 17 (2) ◽  
pp. 27-38 ◽  
Author(s):  
Quang Huu Vinh Luu

A new algorithm simulating the impact of asynchronous torque to the transient stability of multi-machine power system is mentioned and some typical numerical examples are presented in this article. Based on the proposed algorithm this PC program uses the elements of the eigen-image matrix to bring the specific advantages for the calculations of the transient stability of multi-machine power system.The symmetrical and unsymmetrical transient voltages of the VAR supporting devices such as the static var compensators, synchronous machines are simulated under condition of action of the automatic voltage regulation system and the transient frequencies relating to the action of the asynchronous torque are simulated for analyzing of the transient stability in multi-machine power system.

2016 ◽  
Vol 19 (2) ◽  
pp. 16-24
Author(s):  
Quang Huu Vinh Luu

A new algorithm simulating the impacts of the VAR supporting devices such as the static var compensators (SVCs) and the synchronous condensers (SCs) under condition of symmetrical disturbances in multi-machine power system is mentioned. Some typical numerical examples are presented in this article. The comparisons of variation of the state parameters, such as the voltage, frequency, reactive power outputs and asynchronous torques…are simulated under condition of the action of the automatic voltage regulation systems of generators and of the VAR supporting devices. The transient energy margins are calculated and compared to assess the transient stability in multi-machine power system. Basing on this algorithm, the PC program uses the elements of the eigen-image matrix to bring the specific advantages for the simulation of the transient features of state variables.


Author(s):  
G. Fusco ◽  
M. Russo

This paper proposes a simple design procedure to solve the problem of controlling generator transient stability following large disturbances in power systems. A state-feedback excitation controller and power system stabilizer are designed to guarantee robustness against uncertainty in the system parameters. These controllers ensure satisfactory swing damping and quick decay of the voltage regulation error over a wide range of operating conditions. The controller performance is evaluated in a case study in which a three-phase short-circuit fault near the generator terminals in a four-bus power system is simulated.


2013 ◽  
Vol 805-806 ◽  
pp. 334-337
Author(s):  
Shi Wei Su ◽  
You Wei Zhou ◽  
Wei Xiong

Analysis compares the direct access to a single set of wind power systemTwo groups of wind farm access system directlyMultiple sets of wind farm access system directly And Multiple sets of wind dispersion access system's impact on power system transient stability. And compare the simulation results, Concluded that wind farm access capacity and its topology structure's influence on system transient stability.


2018 ◽  
Vol 10 (11) ◽  
pp. 4140 ◽  
Author(s):  
Seungchan Oh ◽  
Heewon Shin ◽  
Hwanhee Cho ◽  
Byongjun Lee

Efforts to reduce greenhouse gas emissions constitute a worldwide trend. According to this trend, there are many plans in place for the replacement of conventional electric power plants operating using fossil fuels with renewable energy sources (RESs). Owing to current needs to expand the RES penetration in accordance to a new National power system plan, the importance of RESs is increasing. The RES penetration imposes various impacts on the power system, including transient stability. Furthermore, the fact that they are distributed at multiple locations in the power system is also a factor which makes the transient impact analysis of RESs difficult. In this study, the transient impacts attributed to the penetration of RESs are analyzed and compared with the conventional Korean electric power system. To confirm the impact of the penetration of RESs on transient stability, the effect was analyzed based on a single machine equivalent (SIME) configuration. Simulations were conducted in accordance to the Korean power system by considering the anticipated RES penetration in 2030. The impact of RES on transient stability was provided by a change in CCT by increasing of the RES penetration.


2013 ◽  
Vol 2 (3) ◽  
pp. 216
Author(s):  
Rekha Chaudhary ◽  
Arun Kumar Singh

The objective of this paper is to design controller for non-linear power system using Direct Feedback Linearization technique to improve the transient stability and to achieve better voltage regulation. In case of fault in the power system, power angle and the terminal voltage are the parameters which are to be monitored. The simulation has been carried out taking different values of initial power angles and results were obtained for power angle and terminal voltage. To overcome the demerits of DFL-LQ optimal controller and DFL voltage regulator, co-ordinated controller is proposed. Simulation results show that transient stability of a power system under a large sudden fault has been improved by using co-ordinated controller.


2015 ◽  
Vol 2015 ◽  
pp. 1-12 ◽  
Author(s):  
Sandeep Gupta ◽  
Ramesh Kumar Tripathi

A current source converter (CSC) based static synchronous compensator (STATCOM) is a shunt flexible AC transmission system (FACTS) device, which has a vital role as a stability support for small and large transient instability in an interconnected power network. This paper investigates the impact of a novel and robust pole-shifting controller for CSC-STATCOM to improve the transient stability of the multimachine power system. The proposed algorithm utilizes CSC based STATCOM to supply reactive power to the test system to maintain the transient stability in the event of severe contingency. Firstly, modeling and pole-shifting controller design for CSC based STATCOM are stated. After that, we show the impact of the proposed method in the multimachine power system with different disturbances. Here, applicability of the proposed scheme is demonstrated through simulation in MATLAB and the simulation results show an improvement in the transient stability of multimachine power system with CSC-STATCOM. Also clearly shown, the robustness and effectiveness of CSC-STATCOM are better rather than other shunt FACTS devices (SVC and VSC-STATCOM) by comparing the results in this paper.


Sign in / Sign up

Export Citation Format

Share Document