scholarly journals Seismic Response Analysis of a High-Rise-Building with Seismic Isolation Rubber

Author(s):  
A. Takahashi ◽  
K. Motoyama ◽  
K. Misaji
2013 ◽  
Vol 671-674 ◽  
pp. 1341-1345
Author(s):  
Jing Wei Nie ◽  
Hong Bing Liu ◽  
Zhao Fang

The research on elastic-plastic dynamic response analysis of the high-rise building with transfer storey is carried out under different earthquake record inputs.The displacement time- history response of the top floor and the transfer storey, also the displacement envelope diagram and interlayer drift angle envelope diagram are obtained.Theoretical reference for the design of the weak layer is provided.


2021 ◽  
Vol 2021 ◽  
pp. 1-14
Author(s):  
Haotian Zhang ◽  
Fuju Li ◽  
Ji Tai ◽  
Jun Zhou

In the high intensity areas, the application of interlayer spacing technology can achieve the unity of quality and seismic performance of high-rise buildings with enlarged base and multiple tower layers. Through the comparison and analysis of the structural schemes of an enlarged base multiple tower-layer high-rise building, the ultimate seismic isolation scheme was adopted, and its seismic response and seismic performance were analyzed and studied. The results show that the overall seismic isolation effect of the story isolation technique is good, which can greatly reduce the seismic response, and is an effective means to improve the seismic safety of the structure. Considering the structural characteristics of the project, the improvement of the economy and the quality of the building, the use of story isolation technique in the enlarged base multiple tower-layer structure in the high-intensity region is an optimal scheme. Finally, several key technical issues such as the combined seismic isolation scheme of the enlarged base story isolation technique and the additional bending moment of the isolator and the tensile device of the isolator were discussed, which can provide some references for similar engineering practices.


2014 ◽  
Vol 651-653 ◽  
pp. 1260-1265
Author(s):  
Xiao Ping Su

With the extensive use of HSC in the tall building and super high-rise building, the harm of HSC subjected to fire has also been increasing. For the concrete structure in the seismic region after fire, its seismic performance after repair directly relates to the structure safety under the action of possible earthquake in the future. Based on the experimental data in the preliminary research, seismic response analysis on the repaired HSC structure after fire was made according to the principle of uniform section. The results indicate that the seismic performance of HSC frame structure repaired by the principle of uniform section can be restored to the level before fire. But we should pay more attention to the interlaminar maximum displacement of fire storey, which should be partly strengthened when necessary.


Author(s):  
Daegi Hahm ◽  
Min-Kyu Kim ◽  
In-Kil Choi ◽  
Bub Gyu Jeon ◽  
Hyoung Suk Choi ◽  
...  

Seismic isolation system can be an effective alternative to protect the NPPs (Nuclear Power Plants) against to the strong seismic events. Therefore, some research activities to adopt the seismic isolation concept to the design of the next generation NPPs have been progressed for last few years in Korea. Nuclear structures, secondary systems and components must remain undamaged during and after the SSE (Safe Shutdown Earthquake) event. The seismic events will cause the high seismic response in the stiff structural systems and extremely high demands of deformation on the safety-related secondary systems like piping components. If seismic isolation devices are installed in nuclear power plant for seismic stability, safety against seismic load of power plant may be improved. But in some equipment, seismic risk may increase because displacement may become greater than before installation of seismic isolation device. Therefore, it is necessary to select the equipment in which seismic risk increases due to increase in displacement by the installation of seismic isolation device, and perform a research on seismic performance evaluation of equipment. In this study, one of the typical Korean NPPs assuming the application of seismic isolation devices, and one of the interface piping systems which introduced this NPP was used for seismic analysis. The numerical models include representations of seismic isolation devices. In order to validation of numerical piping system model and defining failure mode & limit states, quasi-static loading tests were conducted on the scale-modeled piping components before the analysis procedures. The fragility analysis was performed by using results of inelastic seismic response analysis. Inelastic seismic response analysis was carried out by using shell finite element model of piping system considering internal pressure. The implicit method was used for the direct integration time history analysis. Generally, PGA (Peak Ground Acceleration) was used for seismic intensity of fragility curve. However, in the case of the displacement sensitive system, lateral displacement could be an useful alternative measure for estimation of probability of failure. Thus in this paper, fragility curves were plotted based on maximum relative displacement.


2010 ◽  
Vol 163-167 ◽  
pp. 3964-3971
Author(s):  
Zhen Xuan Zhang ◽  
Qing Jun Chen

Based on seismic records with large long-period components at home and abroad, carried on uniform error correction processing and rough site classification, then, used numerical analysis software-MATLAB to calculate the average response spectrum of different types of venues, and used the least square method to do sub-fitting for them, got the long-period quasi-regulatory response spectrums of all kinds of venues; using the general-purpose finite element analysis software-ANSYS, a super high-rise building structural analysis model was established, inputted the fitted long-period seismic response spectrum and the design response spectrum of Shanghai anti-seismic standards, by comparing the results of structural seismic responeses under the two kinds of response spectrum, the long-period seismic response of super high-rise building was investigated, and some valuable conclusions were obtained for reference.


Sign in / Sign up

Export Citation Format

Share Document