scholarly journals PERANCANGAN ALAT UJI TARIK MORTAR MENGGUNAKAN TENAGA PENGGERAK MOTOR LISTRIK

2018 ◽  
Vol 17 (1) ◽  
Author(s):  
Sarito Sarito ◽  
Muhtarom Riyadi ◽  
Handi Sudardja

ABSTRACTMechanic characteristics of hard mortar are: compressive strength, flexural strength, tensile strength, and adhesion power. In the meantime, at Building Material Laboratory of Civil Engineering, State Polytechnic of Jakarta, test of tensile strength and adhesion power of mortar cannot be conducted because of the absence of the test equipment.This research aims to provide electric motor-powered equipment for tensile strength test of mortar in order to complete the equipment at Building Material Laboratory of Civil Engineering, State Polytechnic of Jakarta. The particular aim of the research is to make prototype of mortar tensile strength test equipment.In this research a prototype of motor-powered mortar tensile strength test equipment and the specimens, to test the performance of the equipment, were prepared. By examining the obstacles and shortcomings, this equipment is a development of the previous research by Muhtarom Riyadi and the team, 2015. The specimens, as the sample to test the equipment, were prepared by the ratio of one part of cement and three part of fine aggregate, with the total number of the specimens of 50 pieces.By analyzing the result of observation in trial period, the equipment could function as it should be. The magnitude of maximum tensile strength that causes the mortar specimens to break depends on the quality, age, and tensile area of mortar, which magnitude can be observed in manometer or scale with the unit of kilogram.Keywords: equipment, tensile, mortar, electric motorABSTRAKSifat mekanis mortar keras antara lain kuat tekan, kuat lentur, kuat tarik dan daya lekat. Sementara ini di Laboratorium bahan bangunan Jurusan Teknik Sipil Politeknik Negeri Jakarta untuk uji kuat tarik dan daya lekat mortar belum bisa dilaksanakan karena belum adanya peralatan untuk melakukan pengujian.Penelitian ini bertujuan untuk membuat alat uji tarik mortar menggunakan tenaga penggerak motor listrik guna melengkapi peralatan yang diperlukan di Laboratorium bahan bangunan Jurusan Teknik Sipil Politeknik Negeri Jakarta. Target khusus yang ingin dicapai adalah membuat prototype alat uji tarik mortar.Dalam penelitian ini akan dibuat prototipe alat uji tarik mortar menggunakan tenaga motor listrik dan cetakan benda ujinya, sekaligus untuk menguji kinerjanya. Alat ini merupakan pengembangan oleh peneliti yang terdahulu Muhtarom Riyadi dan anggotanya, 2015), dengan mencermati kendala dan kekurangannya maka penelitian ini merupakan penyempurnaan penelitian sebelumnya Sebagai sampelnya dibuat benda uji tarik mortar dengan perbandingan 1 bagian semen berbanding 3 bagian pasir, sedangkan jumlah benda uji dibuat sebanyak 50 buah.Hasil pengamatan selama uji coba maka alat alat uji tarik mortar menggunakan tenaga penggerak motor listrik dapat berfungsi sebagaimana mestinya. Besarnya gaya tarik maksimum yang menjadikan benda uji tarik mortar putus tergantung dari mutu mortar, umur serta luas penampang tarik yang nilainya dapat diamatai pada manometer atau timbangan berat dengan satuan kilogramKata kunci : Alat, uji, tarik, mortar, motor listrik

Author(s):  
S. B. Kandekar ◽  
◽  
S. K. Wakchaure ◽  

Materials are the most important component of building construction. The demands of construction material are increasing day by day significantly. This demand is increasing the material prices and scarcity of material in construction industry. To achieve economical and eco-friendly criteria naturally occurring material is selected. Clay is a natural material and it can be available easily. This paper interprets the experimental investigation on strength of concrete using clay as a partial replacement to binder content (cement) in concrete. The replacement percentages are grouped as 0%, 10%, 20%, 30%, 40% of clay and 5% of hydrated lime with cement in each series in M25 grade of concrete. To achieve the pozzolanic property of clay hydrated lime was added. Different tests are performed to determine the optimum percentage of clay as a replacement for binder content (cement) in concrete. The Compressive strength test, split tensile strength test and flexural strength test were performed on the specimens. Total 90 cubes of size 150 mm were prepared for compressive strength test, 30 cylinders of 150 mm diameter and 300 mm height were prepared for split tensile strength test and 30 beams of size 150 mm x 150 mm x 1000 mm were prepared to carry out the flexural strength test. The results are compared to find the ideal proportion of clay as a replacement for cement. It is found that 10% replacement with 5% hydrated lime gives satisfactory results.


Author(s):  
C. Mounika

Abstract: The main aim of this project is to evaluate mechanical properties of interlocking bricks using coir fiber powder as a substitute of cement and rubber tire waste as a substitute of fine aggregate (sand) with varying percentages of 0%, 1%, 2% & 3% and 0%, 5%, 10% & 15% in concrete and to help in solving environmental problem produced from disposing of waste tires and coir husk partially. Additionally fly ash was also added with varying percentages of 5%, 10% and 15% as a substitute to cement in a concrete mix. Several laboratory tests such as compressive strength test, flexural strength test, split tensile strength test, water absorption test and density of concrete etc., were conducted on hardened concrete specimen to achieve the optimum usage of crumb rubber tire waste and coir fiber powder in mix proportion of concrete. It is found that the maximum compressive strength value of coir fiber based crumb rubber interlocking brick was obtained at 1%CF + 5%FA + 5%CR, flexural strength value and split tensile strength value of coir fiber based crumb rubber concrete block was obtained at 1%CF + 5%FA + 5%CR. From the final conclusion or outcome of the project, optimum usage of coir fiber powder is 3% and crumb rubber is 5%. Keywords: coir fiber powder, crumb rubber tire waste, mechanical properties, interlocking bricks & optimum usage.


2021 ◽  
Vol 14 (2) ◽  
pp. 30
Author(s):  
Armin Naibaho ◽  
Agus Sugiarto ◽  
Purnama Dewi

Abstract The use of the mountain seal used as a building block for concrete should be considered, based on current usage apart from being a light construction material for housing, mountain materials from these two places are used as the main aggregate material for building construction, water structures (dams), roads. and bridges located in the surrounding Malang-Kota Batu area To determine the size of the aggregate, the coarse aggregate is sieved using a vibrating sieve, while the fine aggregate is sieved by a hydraulic sieve. In the screening process, about 70% of the filtered must pass so that high efficiency and capacity can be achieved. The compressive strength test results obtained the average compressive strength value at 28 days of concrete for concrete with fine aggregate sand zone III and coarse aggregate (gravel) in the Batu City area is equivalent to 35.65 MPa. The results of the split tensile strength test showed that the average split strength value at the age of 28 days for concrete with fine aggregate sand zone III and coarse aggregate (gravel) in the Kota Batu area is equivalent to 2.51 MPa. The compressive strength value for normal concrete is 35.65 MPa, it should produce split tensile strength = 4.179 MPa according to the provisions of SNI T-15-1991-03 Article 3.2.5 (fr = 0.70√fc '). Even though the split tensile strength value obtained in the laboratory is only 2.51 MPa, this means that the quality of materials (sand and broken stone) from Batu City is not suitable for use as building materials. Because the number 2.51 MPa is relatively much smaller than the value of 4.179 MPa, it is only one of the factors outlined in the SNI T-15-1991-03 article 3.2.5. Keywords: Mountain Material, Concrete, Concrete Compressive Strength Test, Concrete Tensile Strength Test


2021 ◽  
Vol 3 (3) ◽  
pp. 49-61
Author(s):  
Meisye Mitha Siranga ◽  
Suryanti Rapang Tonapa ◽  
Frans Phengkarsa

The use of concrete in Indonesia cannot be separated from skyscrapers, bridges with long spans, and underground buildings which generally have a larger load, so the use of high-strength concrete is necessary. This study aims to determine the value of compressive strength, split tensile strength, flexural strength, modulus of elasticity of concrete and determine the workability of fresh concrete with the addition of 0.8% superplaticizer. The test objects used in the form of cylinders with a diameter of 15 cm and a height of 30 cm as many as 15 pieces, and 3 pieces of blocks measuring 15 cm × 15 cm × 60 cm. From the results of the study, the compressive strength value was 43,007 MPa. The split tensile strength test is 3.584 MPa. The flexural strength test is 4,340 MPa. The elastic modulus test is 28447.956 MPa. From the slump test on fresh concrete with the addition of a superplaticizer, it is obtained by 10 cm.


2020 ◽  
Vol 14 (2) ◽  
pp. 30
Author(s):  
Armin Naibaho ◽  
Agus Sugiarto ◽  
Purnama Dewi

Abstract The use of the mountain seal used as a building block for concrete should be considered, based on current usage apart from being a light construction material for housing, mountain materials from these two places are used as the main aggregate material for building construction, water structures (dams), roads. and bridges located in the surrounding Malang-Kota Batu area To determine the size of the aggregate, the coarse aggregate is sieved using a vibrating sieve, while the fine aggregate is sieved by a hydraulic sieve. In the screening process, about 70% of the filtered must pass so that high efficiency and capacity can be achieved. The compressive strength test results obtained the average compressive strength value at 28 days of concrete for concrete with fine aggregate sand zone III and coarse aggregate (gravel) in the Batu City area is equivalent to 35.65 MPa. The results of the split tensile strength test showed that the average split strength value at the age of 28 days for concrete with fine aggregate sand zone III and coarse aggregate (gravel) in the Kota Batu area is equivalent to 2.51 MPa. The compressive strength value for normal concrete is 35.65 MPa, it should produce split tensile strength = 4.179 MPa according to the provisions of SNI T-15-1991-03 Article 3.2.5 (fr = 0.70√fc '). Even though the split tensile strength value obtained in the laboratory is only 2.51 MPa, this means that the quality of materials (sand and broken stone) from Batu City is not suitable for use as building materials. Because the number 2.51 MPa is relatively much smaller than the value of 4.179 MPa, it is only one of the factors outlined in the SNI T-15-1991-03 article 3.2.5. Keywords: Mountain Material, Concrete, Concrete Compressive Strength Test, Concrete Tensile Strength Test


2019 ◽  
Vol 258 ◽  
pp. 01024 ◽  
Author(s):  
Teddy Tambunan ◽  
Mohd. Irwan Juki ◽  
Norzila Othman

In construction, concrete durability is an important material globally used in engineering, material of which can be applied in the fields of specialized marine construction. The ingress of chloride into concrete causes deterioration in the concrete due to the reinforcement corrosion. Adding bacteria into concrete can improve material properties and increase durability with mechanism resist chloride ingressed in the concrete . Ingress of Chloride into the concrete of bacteria is particularly suited for applications of chloride ion penetration in concrete. The objective of the research is to determine the effect of adding bacteria into the concrete properties. The bacteria used in this research is locally isolated and enriched to the suite with the concrete environment. The type of the bacteria used is identified as Sulphate Reduction Bacteria (SRB). The SRB added into the concrete mix with concentrations of 3%, 5% and 7%. Whereas, concentration of bacteria water of cement is 0.5. The mechanical properties test conducted with 28th, 56th, 90th, 180th and 360th day of curing period. The test was using cyclic wetting and drying to study the exposure to chloride condition, such as compressive strength, tensile strength and flexural test. Cubes in the size of 150 mm × 150 mm × 150 mm were prepared for compressive strength test and cylinder 150 mm × 300 mm were prepared for the tensile strength test. The flexural strength test was on the prism in the size of 100 mm × 100 mm × 500 mm. The result of compressive strength test shows, that gave significant strength of 66.3 MPa on the 360th day. The tensile strength and flexural strength have a similar trend as compressive strength results, where both results were optimum . The tensile strength test shows that 4.52 MPa tends to control 3.96 MPa. The result of flexural strength test was 8.23 MPa for compared to control of 5.99 MPa. The overall results of the bacteria indicate promising outcome and further study on chloride condition capability is encouraging.


2021 ◽  
Vol 2 (2) ◽  
pp. 2474-2489
Author(s):  
Thyago Lima Souza ◽  
Adriano Lopes Gualberto Filho ◽  
Deividy Kaik de Lima Araujo ◽  
Marcos André Lira Silva ◽  
Marco Antônio Assis De Oliveira ◽  
...  

The study of the use of kaolin waste has scientific and socio-environmental value by providing an appropriate destination, reducing the demand and consequent problems arising from its extraction, considering that the construction industry is a consumer of a significant amount of raw material. Thus, the study aims to replace the fine aggregate by kaolin waste in the proportions of 10%, 20% and 30%, verifying its feasibility for interlocking sidewalk pieces. The kaolin waste was used with and without fine material, and physical characterization tests of the materials were performed, and then the concrete pieces were subjected to tests of resistance to simple compression, water absorption and resistance to abrasion, as prescribed by ABNT NBR 9781:2013, and flexural tensile strength test, according to ABNT NBR 12142:2010. According to the results and analyzing the compressive strength at 28 days, the mixtures with replacement of 10% of fine aggregate by kaolin waste reached strengths greater than 35 MPa, an acceptable normative parameter, both for the waste with fines and without fines, making its use feasible.


2019 ◽  
Vol 3 (2) ◽  
pp. 81-89
Author(s):  
Angga Pirman Firdaus ◽  
Jonbi

Indonesia ranks second in the world's largest plastic waste producer after China. Each year, Indonesia can contributeup to 187.2 million tons of plastic waste, while China reaches 262.9 million tons of plastic waste. Based on the data, one way to utilize plastic waste by using plastic waste as a mixture of concrete, where the plastic used is polypropylene (PP) plastic with different percentage of concrete mixture, the test includes compressive strength test and tensile concrete. The results of concrete compressive strength testing with polypropylene (PP) plastic waste mixture of 5%, 10% and 15% at age 28 in aggregate aggregate mixture decreased by 5.15%, 6.89% and 13.53%. As for the result of concrete tensile strength test with polypropylene (PP) plastic waste mixture of 5%, 10% and 15% at age 28 in crude aggregate mixture decreased 17,61%, 24,13% dan 23,24%.


2019 ◽  
Vol 9 (1) ◽  
pp. 15-22
Author(s):  
Era Rizky Hasanah ◽  
Agustin Gunawan ◽  
Yuzuar Afrizal

Concrete has a high compressive strength, but it is low to tensile strength. The pinang skin fiber and wood powderuse to increase the tensile strength. The purpose of this research is to know the effect of addition toward tensile strength and addition percentage variation in concrete that will get the highest tensile strength.The cylindrical specimens with size of 30 cm high and 15 cm diameter to 20 specimens, they are 4 sample of normal concrete and 16 sample of variation oncrete. The addition of pinang skin fiber and wood powder with variation of 0.25%, 0.5%, 0.75%, and 1% of the weight volume of the specimen with used 50% pinang skin fiber and 50% wood powder.The mixture of concrete uses water cement ratioof 0.5 and 60-100 mm slump.The test specimen is immersed for 26 days and the concrete tensile strength test conducted after the concrete at 28 days adding 7 days for drying.The result of this research shows that the variation concrete of 0.25% and 0.5% have increased of tensile strength than the normal concrete as 12.272% and 4.369%. Beside that for the variation concrete of 0.75% and 1% have decreased as 5.044% and 11.929%. The increase of tensile strength value of optimal concrete is found in variation 0.25% that is 12.272% from normal concrete.


Copper slag is a rough blasting grit or a by-product acquired by the process of copper smelting and refining. These copper slags are recycled for copper recovery. In this paper, we analysed copper slag’s feasibility and evaluate its total competence in M25 grade concrete. In this observation, a concrete mixture is applied with copper slag as a fine aggregate ranging from 0%, 20%, 40%, 60%, 80%, and 100% respectively. The strength of copper slag’s implementation is accomplished on the basis of concrete’s flexural strength, compressive strength and splitting tensile strength. From the obtained results, in concrete 40% percentage of copper slag is used as sand replacement. On 28 days, the modulus of elasticity increased up to 32%, the compressive strength increased up to 34% and flexural strength is increased to 6.2%. From this experiment, it is proved technically that replacing sand using copper slag as a fine mixture in M25 grade concrete.


Sign in / Sign up

Export Citation Format

Share Document