scholarly journals Experimental study on web crippling of lapped cold-formed steel channels subjected to interior two-flange loading

2021 ◽  
Author(s):  
Quzzafi Rahman

The current North American Specifications for the Design of Cold-Formed Steel (CFS) Structural Members, AISI-S136-01, specifies expressions for web crippling strength of different joist geometries in case of exterior end and concentrated load locations. However, it does not permit an in increase two-flange loading. Thus, the objective of this research in this thesis is to generate experimental data for CFS channels where both webs of channel members are lapped at the interior support location and being loaded simultaneously. This thesis summarizes the results of a parametric study to examine few parameters that affect web crippling strength of such lapped channels. These parameters include the unbraced length of channel member, the presence screws, the level of flange restraint at the interior support location, channel six and load bearing length (i.e. lap length). Test specimens were loaded to failure and load history and the failure pattern were recorded. Based on experimental findings, a reliable and economical design expression was developed for web crippling strength of lapped CFS channels at interior support location when subjected to two-flange loading.

2021 ◽  
Author(s):  
Quzzafi Rahman

The current North American Specifications for the Design of Cold-Formed Steel (CFS) Structural Members, AISI-S136-01, specifies expressions for web crippling strength of different joist geometries in case of exterior end and concentrated load locations. However, it does not permit an in increase two-flange loading. Thus, the objective of this research in this thesis is to generate experimental data for CFS channels where both webs of channel members are lapped at the interior support location and being loaded simultaneously. This thesis summarizes the results of a parametric study to examine few parameters that affect web crippling strength of such lapped channels. These parameters include the unbraced length of channel member, the presence screws, the level of flange restraint at the interior support location, channel six and load bearing length (i.e. lap length). Test specimens were loaded to failure and load history and the failure pattern were recorded. Based on experimental findings, a reliable and economical design expression was developed for web crippling strength of lapped CFS channels at interior support location when subjected to two-flange loading.


2010 ◽  
Vol 163-167 ◽  
pp. 90-101 ◽  
Author(s):  
Xing You Yao ◽  
Yuan Qi Li ◽  
Zu Yan Shen

Distortional buckling may occur for Cold-formed thin-walled steel lipped channel member except local buckling and overall buckling. The buckling of flange and lip are the important factor for the occurrence the distortional buckling. The different design codes have different design method for calculating plate buckling coefficient of flange and lip using the effective width method. So the effective width method in different codes are introduced and the load-carrying capacities of 100 lipped channel section compressive members collected from reference are computed using ‘Cold-formed steel structures (AS/NZS 4600:2005)’, ‘Supplementary rules for cold-formed members and sheeting(EN1993-1-3:2006)’, ‘North American specification for the design of cold-formed steel Structural Members(AISI-S100:2007)’, ‘Specification for the design of cold-formed steel structural members (AISI:1996)’ and ‘Technical code of cold-formed thin-walled steel structures’(GB50018-2002). The calculated results show that ‘Technical code of cold-formed thin-walled steel structures (GB50018-2002)’ and ‘Supplementary rules for cold-formed members and sheeting (EN1993-1-3:2006)’ are conservative and ‘Cold-formed steel structures (AS/NZS 4600:2005)’, ‘North American specification for the design of cold-formed steel Structural Members (AISI-S100:2007)’ and ‘Specification for the design of cold-formed steel structural members (AISI:1996)’ are unsafe. The elastic buckling stress of different lipped channel sections are predicted by finite strip program (CUFSM) and get the suggested calculation formula of plate buckling coefficient of flange according to regression Analysis. The calculated results using suggested plate buckling coefficient of flange are agree to test results.


2012 ◽  
Vol 166-169 ◽  
pp. 322-328
Author(s):  
Huai Lin Peng ◽  
Feng Zhou ◽  
Le Wei Tong

A series of tests on cold-formed steel square and rectangular hollow sections subjected to web crippling is reported in this paper. The web crippling tests were conducted under two loading conditions of end-two-flange (ETF) and interior-two-flange (ITF), which are specified in the current North American Specification for cold-formed steel structures. The concentrated load was applied by means of bearing plates, which act across the full flange width of the specimen sections. Different bearing lengths were investigated. The test specimens were fabricated by cold-rolling from steel sheet with nominal yield strength of 345MPa. The measured web slenderness values of the tubes ranged from 15.5 to 46.0. The test strengths obtained from this study are compared with the design strengths obtained using the current North American Specification, Australia Standard, European Code and Chinese Code for cold-formed steel structures. It is shown that the design strengths predicted by the specifications are either unreliable or too conservative.


1983 ◽  
Vol 38 (5) ◽  
pp. 503-508 ◽  
Author(s):  
A. R. Jani ◽  
V. B. Gohel

Debye-Waller factors at different temperatures of four alkali and three noble metals have been computed on the basis of a screened shell phenomenological model. The theoretical values are compared with existing experimental data. Particularly for lithium and potassium, most recent experimental information has been included. A critical examination of the results reveals a satis­factory agreement between the theoretical and experimental findings.


2022 ◽  
Vol 1048 ◽  
pp. 321-332
Author(s):  
A. Kumar Suresh ◽  
M. Muthukannan ◽  
R. Kanniga Devi ◽  
K. Kumar Arun ◽  
Ganesh A. Chithambar

This study aims to analyze the use of Incinerated Bio-Medical Waste Ash (IBWA) in reinforced concrete structural member with ground granulated blast furnace slag (GGBS) as an alternate building ingredient instead of cement. Biomedical waste was produced from various medical resources such as hospitals, medical institutes and research centres. GGBS is the waste generated from the steel plant. The climate is now being affected by the release of CO2 (global warming) from the Portland cement industries. Therefore, greater attention must be paid to study efforts to use geopolymer concrete. Geopolymer is a novel inorganic eco-friendly binding agent derived from an alkaline solution that stimulates aluminosilicate source material (GGBS, Rice Husk Ash, Quartz Powder, metakaolin, fly ash and Silica Fume). In this research, laboratory tests for Reinforced Geopolymer Concrete (RGPC) beams (deflection, ductility factor, flexural strength and toughness index) and columns (load-carrying ability, stress-strain behaviour and load-deflection behaviour) were conducted for three types of proportions using [30% IBWA – 70% GGBS Geopolymer concrete, GGBS Geopolymer concrete and Reinforced Cement Concrete. The experimental findings revealed that the performance of reinforced 30% IBWA – 70% GGBS geo-polymer beams and columns worked more effectively than reinforced cement concrete beams and columns.


1983 ◽  
Vol 27 (04) ◽  
pp. 252-264
Author(s):  
Owen Hughes

In the design of plating subject to lateral loading, the principal load effect to be considered is the amount of permanent set, that is, the maximum permanent deflection in the center of each panel of plating bounded by the stiffeners and the crossbeams. The present paper is complementary to a previous paper [1]2 which dealt with uniform pressure loads. It first shows that for design purposes there are two types of concentrated loads, depending on the number of different locations in which they can occur; single location or multiple location. The hypothesis is then made that for multiple-location loads the eventual and stationary pattern of plasticity which is developed in the plating is very similar to that for uniform pressure loads, and hence the value of permanent set may be obtained by using the same formula as for uniform pressure loads, with a load parameter Q that is some multiple r of the load parameter for the concentrated load: 0 = rQP. The value of r is a function of the degree of concentration of the load and is almost independent of plate slenderness and aspect ratio. The general mathematical character of this function is established from first principles and from an analysis of the permanent set caused by a multiple-location point load acting on a long plate. The results of this theoretical analysis provide good support for the hypothesis, as do also the relatively limited experimental data which are available. The theory and the experimental data are combined to obtain a simple mathematical expression for r. A more precise expression can be obtained after further experiments have been performed with more highly concentrated loads. Single-location loads produce a different pattern of plasticity and require a different approach. A suitable design formula is developed herein by performing regression analysis on the data from a set of experiments performed with such loads. Both methods presented herein, one for multiple-location loads and the other for single-location loads, are valid for small and moderate values of permanent set and can be used for all static and quasistatic loads. Dynamic loads and applications involving large amounts of permanent set require formulas based on rigid-plastic theory. Such formulas are available for uniform pressure loads and were quoted in reference [1]. A formula for single-location loads has recently been derived by Kling [4] and is quoted herein.


Sign in / Sign up

Export Citation Format

Share Document