scholarly journals Determination of the optimal duration of the process of washing parts in a synthetic detergent solution

Author(s):  
I.A. Uspensky ◽  
◽  
S.N. Kulik ◽  
E.V. Mitrokhina ◽  
I.V. Fadeev ◽  
...  
1983 ◽  
Vol 29 (8) ◽  
pp. 1513-1517 ◽  
Author(s):  
M W McGowan ◽  
J D Artiss ◽  
B Zak

Abstract A procedure for the enzymatic determination of lecithin and sphingomyelin in aqueous solution is described. The phospholipids are first dissolved in chloroform:methanol (2:1 by vol), the solvent is evaporated, and the residue is redissolved in an aqueous zwitterionic detergent solution. The enzymatic reaction sequences of both assays involve hydrolysis of the phospholipids to produce choline, which is then oxidized to betaine, thus generating hydrogen peroxide. The hydrogen peroxide is subsequently utilized in the enzymatic coupling of 4-aminoantipyrine and sodium 2-hydroxy-3,5-dichlorobenzenesulfonate, an intensely red color being formed. The presence of a non-reacting phospholipid enhances the hydrolysis of the reacting phospholipid. Thus we added lecithin to the sphingomyelin standards and sphingomyelin to the lecithin standards. This precise procedure may be applicable to determination of lecithin and sphingomyelin in amniotic fluid.


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Gianluca Trinco ◽  
Valentina Arkhipova ◽  
Alisa A. Garaeva ◽  
Cedric A. J. Hutter ◽  
Markus A. Seeger ◽  
...  

AbstractIt is well-established that the secondary active transporters GltTk and GltPh catalyze coupled uptake of aspartate and three sodium ions, but insight in the kinetic mechanism of transport is fragmentary. Here, we systematically measured aspartate uptake rates in proteoliposomes containing purified GltTk, and derived the rate equation for a mechanism in which two sodium ions bind before and another after aspartate. Re-analysis of existing data on GltPh using this equation allowed for determination of the turnover number (0.14 s−1), without the need for error-prone protein quantification. To overcome the complication that purified transporters may adopt right-side-out or inside-out membrane orientations upon reconstitution, thereby confounding the kinetic analysis, we employed a rapid method using synthetic nanobodies to inactivate one population. Oppositely oriented GltTk proteins showed the same transport kinetics, consistent with the use of an identical gating element on both sides of the membrane. Our work underlines the value of bona fide transport experiments to reveal mechanistic features of Na+-aspartate symport that cannot be observed in detergent solution. Combined with previous pre-equilibrium binding studies, a full kinetic mechanism of structurally characterized aspartate transporters of the SLC1A family is now emerging.


2018 ◽  
Vol 3 (1) ◽  
pp. 66-68
Author(s):  
M T Nasretdinova ◽  
H E Karabaev

Aim - to present the results of the observational program, the purpose of which was to reduce visual disorders associated with vestibular dysfunction, and restore balance, thereby reducing the risk of falls. Materials and methods. 46 patients took part in the observational study. Determination of the optimal duration of vestibular rehabilitation in patients with unilateral non-progressive peripheral vestibular disorder. Results. It was found that the optimal duration of treatment is no less than 2 months.


1969 ◽  
Vol 56 (1) ◽  
pp. 109-111 ◽  
Author(s):  
D. THIRKELL ◽  
M. I. S. HUNTER ◽  
J. CRAWFORD ◽  
A. S. FRACASSINI

Author(s):  
N. Hong Son ◽  
H. Van Nam ◽  
T. Trung Hieu ◽  
V. Van Khiem ◽  
H. Nhu Tan ◽  
...  

There are many parameters affecting the amount of removed rust on the steel surface during ultrasonic cleaning. This article presents the experimental study results to determine the value range of some paratmeters of machining process to ensure the amount of removed rust on the steel surface with great value. Tests were performed in two different detergent solution media of without using acid and using acid. The reasonable value ranges of machine power, machining time, distance from steel plate to ultrasonic transducer (called machining distance) and detergent solution concentration have been determined. From the results achieved in this paper, the development direction for the next studies has also been proposed.


Sign in / Sign up

Export Citation Format

Share Document