scholarly journals Comparison of force degradation and color change of esthetic elastomeric chains

2021 ◽  
Vol 10 (4) ◽  
pp. e54310414307
Author(s):  
Maria Julia Lima Motta ◽  
Victor de Miranda Ladewig ◽  
Joel Ferreira Santiago Junior ◽  
Renata Rodrigues Almeida-Pedrin ◽  
Thais Maria Freire Fernandes Poleti ◽  
...  

Objective: this study compared the force degradation and color change of esthetic elastomeric chains of four commercial brands. Materials and methods: the study analyzed 10 medium-force esthetic elastomeric chains with 6 links of Morelli, Orthometric, Eurodonto and 3M brands from sealed packages within the expiration date. The elastics were stretched twice their length, according to the manufacturer's recommendations, and were immersed in artificial saliva at 37°C. The forces were measured with an orthodontic dynamometer at onset and at intervals of 1, 7, 14, 21 and 30 days after immersion. The force degradation was evaluated calculating the percentage of force lost in relation to the initial force in each time interval, for each group tested separately and also between them. The color change was evaluated by visual analysis scale by observation of photographs of chain elastics before and after study completion by 31 examiners. The ANOVA test of repeated measures was applied considering 2 factors, time and groups, and the Tukey test was used for analysis of multiple comparisons. A significance value of 0.05% was adopted for the analyses. Results: the elastics showed great force degradation. After 7 days the groups presented degradation around 50% of the initial force. In the evaluation between groups, the elastics showed significantly different mean forces. When assessing color change, the scores assigned by examiners evidenced less color changes for elastics of Eurodonto brand. Conclusion: regardless of the commercial brand, transparent elastomeric chains show significant force degradation values ​​after 1 day. The scores assigned to color change evidenced that all commercial brands showed staining, with the best results for Eurodonto elastics.

2015 ◽  
Vol 44 (5) ◽  
pp. 262-267 ◽  
Author(s):  
José Vitor Quinelli Mazaro ◽  
Luiz Miguel Minani ◽  
Adriana Cristina Zavanelli ◽  
Caroline Cantieri de Mello ◽  
Cleidiel Aparecido Araújo Lemos

AbstractIntroductionTemporary restorative materials are widely used, however, little is know about their color stability.Objectiveto evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage.Material and methodFour materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) and 30 test specimens (15 mm in diameter and 2 mm thick) per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee) and storage time intervals (2, 5, 7 and 15 days). Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%.ResultAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767). As regards solutions tested, coffee showed the highest color change values (p<0.001), and the longer the storage time interval, the greater was the color change in all the temporary restorative materials analyzed (p<0.001).ConclusionAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.


2021 ◽  
Vol 24 (3) ◽  
Author(s):  
Heba El-khayat ◽  
Hesham Katamish ◽  
Amr El-Etreby ◽  
Mostafa Aboushahba

Objective: The aim of this study is to evaluate the effect of varying thickness and artificial aging on the color and translucency of cubic zirconia and lithium disilicate ceramics. Material and Methods: A total of 30 square shaped disks (12 mm x 12 mm) were fabricated from the cubic zirconia (Bruxzir Anterior) blank and lithium disilicate blocks (E.max CAD), used in three thicknesses (0.5mm, 0.8mm and 1mm). Portable spectrophotometer Vita Easyshade Advance was used to obtain color coordinates, which were substituted in formulas and used to calculate color change and translucency parameter values before and after aging (thermocycling for lithium disilicate and hydrothermal aging for cubic zirconia). Repeated measures Analysis of Variance (ANOVA) was used to study the effect of ceramic type, thickness, aging and their interaction on mean translucency parameter. Two-way (ANOVA) was used to study the effect of ceramic type, thickness and their interaction on mean color change (E). Results: Statistical analysis showed that E.max CAD HT is more translucent than Bruxzir Anterior. Translucency decreased as thickness increased. There was a statistically significant decrease in TP after aging for both materials. Lithium disilicate showed statistically significant greater E when subjected to aging than cubic zirconia, with both E values being clinically imperceptible. As thickness increased, E decreased. Conclusions: Thickness highly affected translucency and color of ceramics. As thickness increases, translucency parameter decreases and color change becomes less evident. Aging also causes a significant decrease in translucency parameter and induces color change however color changes are imperceptible. Keywords Aging; Ceramics; Color; Translucency.


2019 ◽  
Vol 48 ◽  
Author(s):  
Mayra Teixeira Cortat LUCINDO ◽  
Diego Patrik Alves CARNEIRO ◽  
Felipe Alexandre de SOUZA ◽  
Américo Bortolazzo CORRER ◽  
Heloisa Cristina VALDRIGHI

Abstract Introduction Elastomers are considered important allies to orthodontic treatment and due to the aesthetic demand, aesthetic elastomers are increasingly used in adult patients. Objective The aim of this experimental in vitro study was to evaluate the degradation of force of esthetic elastomeric chains, of three different sizes: short, medium and long. Material and method For evaluating the degradation of force, 90 elastomeric chain segments were used, divided into 9 Groups (n=10), as follows: Morelli short elastomer, Morelli medium, Morelli long, Orthometric short, Orthometric medium, Orthometric long, American Orthodontic short, American Orthodontic medium and American Orthodontic long. Acrylic plates with pins were used to provide stretching of the elastomeric chains. The initial stretching force of the elastomeric chain was 150 grams, measured by a tensiometer. After this, they were prestretched to 50% of their original length, measured in an Instron 4411 Universal test machine, and placed on the seating pin on the plate. The plate was immersed in artificial saliva at 37 °C in a plastic receptacle, and removed for measurement after a time interval of 21 days. For statistical analysis, the methodology of mixed models for repeated measures in time and Tukey-Kramer test were used. Degradation of the forces was analyzed by 2-way analysis of variance (ANOVA) and the Tukey test. Result All the elastomeric chains showed statistically significant reduction in force (p<0.05). The American Orthodontic elastomeric chains showed higher reduction in force values, irrespective of the elastic size (p<0.05). Conclusion The three commercial brands studied underwent significant reduction in the quantity of force released; the American Orthodontic brand of elastomer showed the highest value of degradation in force.


2017 ◽  
Vol 751 ◽  
pp. 636-642
Author(s):  
Ratcha Raksakmanut ◽  
Ampaporn Nithipratheep ◽  
Ornjira Weeriyanan ◽  
Panida Pittayaporn ◽  
Waivich Komonpale ◽  
...  

The aim of this study was to evaluate the effects of bleaching on color change of stained resin composites. Ninety disk-shaped specimens were prepared with 3 different composite materials (Estelite ∑ Quick, Premise, and Filtek Z350 XT). After stored in artificial saliva at 37°C for 24 hours in an incubator, the 30 specimens of each material were divided into 3 subgroups and immersed in either coffee, red wine, or artificial saliva (control) at 37°C. After 24 days, spectrophotometric measurement was performed. After the staining process, the bleaching agent (Opalescence, 10% carbamide peroxide) was applied to the surface of the specimens, 8 hours per day for 14 days. After the bleaching process, spectrophotometric measurement was performed. The color differences between specimens before and after bleaching were statistically significant (ΔE*ab>3.3) for all composites in the red wine staining. The highest-level color change after bleaching was observed for Filtek Z350 XT in red wine staining, while the least value was found in Estelite ∑ Quick in coffee staining. In summary, color changes of all red wine-stained composites after bleaching were noticeable and have higher level of color change than coffee-stained composites.


2007 ◽  
Vol 21 (1) ◽  
pp. 51-57 ◽  
Author(s):  
Ana Cristina Soares Santos ◽  
André Tortamano ◽  
Sandra Regina Frazatto Naccarato ◽  
Gladys Cristina Dominguez-Rodriguez ◽  
Julio Wilson Vigorito

This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli®, (2) Abzil®, (3) TP Orthodontics® and (4) American Orthodontics®. The specimens were extended to twice their original length and stored in artificial saliva at 37°C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli®, 351 g for American Orthodontics®, 402 g for Abzil®, and 404 g for TP Orthodontics®. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics®, 208 g for TP Orthodontics®, 216 g for Abzil®, and 223 g for Morelli®. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4% for TP Orthodontics®, 48.1% for American Orthodontics®, 65.4% for Morelli®, and 71.6% for Abzil®. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6% for American Orthodontics®, 29.8% for Abzil®, 30.6% for Morelli®, and 45.8% for TP Orthodontics®. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.


2019 ◽  
Vol 30 (1) ◽  
pp. 52-57 ◽  
Author(s):  
Eduardo Haruki Ozera ◽  
Fernanda Miori Pascon ◽  
Américo Bortolazzo Correr ◽  
Regina Maria Puppin-Rontani ◽  
Aline Rogéria de Castilho ◽  
...  

Abstract This study evaluated gloss and color changes of esthetic restorative materials subjected to different acidic beverages. Specimens of resin composites (Z350XT (Z350), IPS Empress Direct (ED), Charisma Diamond (CD)) were prepared and the initial surface gloss and color (ΔE) were measured (n=10). Then, the specimens were immersed in 4 mL of each of the different beverages (cranberry juice; Coca-Cola; coffee or artificial saliva) during 15 min, 3x/day for 14 days and new gloss and color readings were obtained. Color change was evaluated with the ΔE formula and gloss change values were obtained by the formula: (final gloss - initial gloss). Data was submitted to two-way ANOVA followed by Tukey’s post hoc test (a=0.05). CD showed the lowest color change among resin composites. The highest ΔE values were obtained after immersion in coffee and cranberry juice. Coffee promoted the highest gloss change (worst gloss retention), followed by cranberry juice, Coca-cola and artificial saliva (p<0.05). The type of beverage significantly influenced the gloss of resin composites. Coca-cola reduced gloss of the three resin composites in a similar manner. Coffee affected the ED gloss more than that of Z350 and CD, while cranberry juice affected Z350 more than ED and CD. Saliva had a more pronounced effect on the gloss retention of CD than ED. The beverages used in this study influenced the optical surface properties of the composites studied.


2019 ◽  
Vol 44 (3) ◽  
pp. 281-288 ◽  
Author(s):  
KY Kyaw ◽  
M Otsuki ◽  
MS Segarra ◽  
N Hiraishi ◽  
J Tagami

SUMMARY Objective: To investigate the effect of calcium-phosphate–based desensitizers, Teethmate AP paste (TMAP) and Teethmate Desensitizer (TMD) (Kuraray Noritake Dental, Tokyo, Japan), on the prevention of staining on acid-eroded enamel. Methods and Materials: Forty polished enamel samples (4×4×1 mm) from bovine incisors were randomly divided into five groups (n=8). After immersion in 50 mL of 0.5% citric acid (pH 2.5) for 15 minutes to form acid-eroded surfaces, the surfaces were subjected to different treatments with TMAP, TMD, and NaF (0.21% means 950 ppm) for five minutes. Another eroded group was not treated with desensitizer. For the control group, the samples were not eroded or treated. All the samples were stored in artificial saliva (AS) at pH 7.2 for 24 hours at 37°C. The TMAP, TMD, or NaF was reapplied at eight and 16 hours during the 24 hours of storage time. The surface roughness (Sa) was evaluated following ISO 25178 for surface texture using confocal laser scanning microscopy (VK-X 150 series, Keyence, Osaka, Japan) before acid erosion, after acid erosion, and after 24 hours of incubation in AS. Afterward, the color difference was measured with a dental colorimeter (Shade Eye NCC, Shofu, Kyoto, Japan) before and after staining with tea solution. Results: One-way repeated measures analysis of variance showed that acid erosion significantly increased Sa (p&lt;0.001). TMAP- and TMD-treated groups exhibited lower Sa values than the NaF group and the no-desensitizer treatment group. The greatest staining was observed in the NaF group and the no-desensitizer group, while the TMAP and TMD groups significantly decreased the formation of stains. Conclusions: Acid-eroded enamel increased surface roughness and tended to absorb more stains. However, the application of TMAP and TMD moderated the roughness and thus prevented the formation of extrinsic stains.


2010 ◽  
Vol 04 (02) ◽  
pp. 118-127 ◽  
Author(s):  
Randa Hafez ◽  
Doa Ahmed ◽  
Mai Yousry ◽  
Wafa El-Badrawy ◽  
Omar El-Mowafy

Objectives: The purpose of this study was to determine color changes and surface roughness of composites when they were subjected to in-office bleaching.Methods: 12 discs 15 mm in diameter and 2 mm thick were prepared from two shades (A2 & A4) of two composites, Durafil VS (DF) and TPH3 (TPH). Specimens were polished and stored in distilled water for 24 hours at 37°C before being subjected to bleaching, staining, and re-bleaching. Each of the groups of specimens (DF-A2, DF-A4, TPH-A2 and TPH-A4) were subdivided into three subgroups (n=4) and bleached with Beyond, LumaWhite-Plus, and Opalescence-Boost. Specimens were then stained by immersing them in a coffee solution for 48 hours at 37°C, and then they were re-bleached. Colorimetric measurements were performed at baseline, after bleaching, after staining, and after rebleaching. Surface roughness was determined with environmental SEM before and after bleaching. Data were statistically-analyzed.Results: None of the bleaching systems notably changed the color of composites (delta-E<2). Coffee staining affected DF specimens more than TPH. Stained specimens showed variable responses to whitening with no significant color change observed with TPH (delta-E<2) and significant changes observed with DF. Surface roughness significantly changed with bleaching, but the degree varied according to composite shade and bleaching agent.Conclusions: Three in-office bleaching agents had no significant color changes on two composites. DF showed more color change than TPH when immersed in coffee. Stained composites showed different degrees of whitening, with DF showing more response. Bleaching may adversely affect the surface texture of composites. Dentists should take into consideration that composite restorations may not respond to bleaching in the same way that natural teeth do. (Eur J Dent 2010;4:118-127)


2015 ◽  
Vol 1088 ◽  
pp. 519-525
Author(s):  
Hua Li Huang ◽  
Dan Feng ◽  
Hai Huan Gong ◽  
Ai Yang Song ◽  
Song Zhu

Heat-cured denture base resin is an important component in removable partial dentures and complete dentures, and has been widely used in the clinic. However, during long-term use, its appearance may be affected by varying degrees of color change, affecting the appearance and longevity of the dentures. In this study we examined the color changes and water absorption and solubility of dental base resins to investigate the color stability of four types of resin materials: New Century, Heraeus, Nissin and BASIS-HI. They were soaked in artificial saliva (as control), red wine, cola, coffee and tea separately at 37°C for 1, 4 or 12 weeks. Results are presented on which the color changes of dental base resin materials were associated with different denture base resins, soak solutions and storage times. We found that most of the dental resins became darker at prolonged immersion time. Heraeus resins showed more significant changes after soaking in red wine for 12 weeks, and its water absorption and solubility values were also greater than those of the other three types of resins. The color changes of New Century, Nissin and BASIS-HI soaked in the four solutions were relatively stable. The information obtained here will help optimize maintenance of dentures and also inform choice of denture materials.


Author(s):  
Raíssa Manoel Garcia ◽  
Waldemir Francisco Vieira-Junior ◽  
Jéssica Dias Theobaldo ◽  
Flávio Henrique Baggio Aguiar ◽  
Débora Alves Nunes Leite Lima

Abstract Objectives The role of toothpaste used during aesthetic treatments is rarely investigated. The objective was to evaluate the effects of a bioactive glass-based toothpaste (BGT) used before or after the dental bleaching with 35% hydrogen peroxide (HP). Materials and Methods Bovine enamel blocks (4 × 4 mm; n = 12) were submitted to tooth bleaching and different treatments/storage, before or after HP, based on: (1) no toothpaste and immersion in artificial saliva (AS) after HP for 24 hours, 7 days, or 14 days (control); (2) daily BGT use and AS storage for 7 or 14 days (after HP); and (3) daily BGT use and AS storage for 7 or 14 days (prior to HP). Surface and in-depth color were determined using the CIE L*a*b* system (ΔL*, Δa*, Δb*, and ΔE) on enamel surface and underlying dentin. The surface microhardness (SMH) was evaluated using a Knoop microhardness tester. Statistical Analysis Data were submitted to analysis of variance (ANOVA) (color variables), repeated measures ANOVA (SMH), and Tukey’s test (α = 0.05). Results The color changes on the enamel or underlying dentin were not statistically different among the groups (p > 0.05). Twenty-four hours after HP presented a decrease in SMH differing from baseline (p < 0.01). This decrease did not occur in the groups previously exposed to BGT (p > 0.05). BGT use after HP for 7 days differed from group with exclusive AS storage (p < 0.05). Conclusion In-office tooth bleaching can decrease the microhardness of enamel surface; however, the use of BGT promotes the protection or enables the mineral recovery of tooth without the influence the bleaching efficacy.


Sign in / Sign up

Export Citation Format

Share Document