scholarly journals Precisão da adaptação de próteses totais confeccionadas pela tecnologia CAD/CAM: Uma revisão sistemática

2020 ◽  
Vol 9 (10) ◽  
pp. e6839109154
Author(s):  
Laércio Almeida de Melo ◽  
Camila Moreira Lima ◽  
Lucas Lactim Ferrarez ◽  
Delano Neves Silva ◽  
Fabíola Pessôa Pereira Leite

Objetivo: Avaliar a precisão da adaptação de próteses totais confeccionadas pela tecnologia utilizando o desenho e a manufatura assistidas por computador (CAD/CAM).Metodologia: Foi realizada uma revisão sistemática de estudos laboratoriais através das bases de dados Medline-PubMed, Scopus, Scielo, Lilacs, Web of Science e Cochrane Library, usando os descritores: “Complete denture”, “Complete dentures”, “Total denture”, “Total dentures”, “Complete prosthesis”, “Complete prostheses”, “Total prosthesis”, “Total prostheses”, “Computer Aied Design”, “Computer Aied Manufacturing”, “CAD/CAM”, Adaptation” e “Precision”. Três revisores calibrados obtiveram dados e compararam os resultados. Todos os estudos avaliaram a precisão da adaptação de próteses totais confeccionadas pela tecnologia CAD/CAM. Esta revisão seguiu as recomendações do Preferred Reporting Items for Systematic Reviews and Meta-analyzes (PRISMA). Resultados: A estratégia utilizada de busca eletrônica e manual resultou em 863 títulos e resumos. Destes, 10 foram selecionados pelos critérios de inclusão e exclusão e lidos na íntegra. Ao final, 7 foram eleitos para inclusão na revisão. Os estudos selecionados demonstraram resultados satisfatórios em relação a adaptação e efetividade sobre as próteses confeccionadas a partir do processo CAD/CAM quando comparadas aos métodos convencionais. Conclusão: Os estudos in vitro demonstraram que o processo de fabricação de prótese total por meio do sistema CAD/CAM apresenta melhor precisão de adaptação quando comparados ao método convencional. O método de fresagem apresentou resultados superiores quando comparado ao por impressão 3D.

2021 ◽  
Vol 10 (2) ◽  
pp. e7810212093
Author(s):  
Millena Silva Cardoso ◽  
Laís Ferrante de Faria ◽  
Camila Moreira Lima ◽  
Fabíola Pessôa Pereira Leite ◽  
Laércio Almeida de Melo

Objetivo: O objetivo dessa revisão sistemática foi avaliar a influência das diferentes concentrações do ácido hidrofluorídrico (HF) no condicionamento das cerâmicas vítreas. Materiais e Métodos: Esta revisão reuniu estudos in vitro a partir de buscas nas bases Cochrane Library, Lilacs, PubMed, SciElo, Scopus e Web of Science, através dos descritores “Veneers”, “Crowns”, “Ceramics”, “Ceramic”, “Surface Treatments”, “Surface”, “Hydrofluoric Acid Concentration”, “Acid Concentration”, “Adhesion”, “Hydrofluoric Acid”. Foram incluídos estudos que investigaram os efeitos da concentração do ácido hidrofluorídrico através de diferentes concentrações entre grupos. O nível de evidência dos artigos selecionados seguiu os princípios do Oxford Center for Evidence-Based Medicine. Esta revisão seguiu as recomendações do PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyzes). Resultados: As estratégias de busca encontraram 151 títulos, dos quais 8 foram eleitos e incluídos nessa revisão. Os parâmetros de avaliação incluíram a influência da concentração do ácido quanto a resistência a flexão, rugosidade superficial, ângulo de molhamento e resistência ao microcisalhamento. Nos estudos, as cerâmicas foram condicionadas com diferentes tipos de concentração e, no geral, o HF a 5% teve o melhor desempenho. Conclusão: Os estudos encontraram mais resultados negativos para as concentrações mais baixas (1% e 3%). Apesar de algumas vantagens, o HF a 10% também não teve os melhores resultados, os quais foram de autoria do HF a 5%. Além disso, a concentração não pode ser vista como o único e principal fator importante na qualidade de adesão das cerâmicas.


2021 ◽  
Vol 10 (2) ◽  
pp. e18819212240
Author(s):  
Laís Ferrante de Faria ◽  
Millena Silva Cardoso ◽  
Camila Moreira Lima ◽  
Laércio Almeida de Melo ◽  
Fabíola Pessôa Pereira Leite

Objetivo: Objetivou-se avaliar a influência do tempo de condicionamento do Ácido Hidrofluorídrico (HF) em diferentes cerâmicas vítreas, a fim de estabelecer o melhor protocolo que viabilize uma adequada adesão protética do material restaurador. Metodologia: Trata-se de uma revisão sistemática de estudos in vitro. Para a sua realização, utilizou-se os descritores “Veneers”, “Crowns”, “Ceramics”, “Ceramic”, “Etching Time”, “Application Time”, “Surface Treatments”, “Hydrofluoric Acid” e “Adhesion” nas bases Scopus, PubMed, Cochrane Library, SciElo, Web of Science e Lilacs. Estudos que investigaram os efeitos do tempo de aplicação do HF sobre a adesão de cerâmicas vítreas foram incluídos. O nível de evidência dos artigos selecionados seguiu os princípios do Oxford Center for Evidence-Based Medicine. Esta revisão seguiu as recomendações do Preferred Reporting Items for Systematic Reviews and Meta-analyzes (PRISMA). Resultados: A estratégia de busca resultou em 290 estudos, dos quais 5 foram incluídos na revisão. Os estudos demonstraram diferentes parâmetros avaliativos como rugosidade microestrutural, molhabilidade, resistência ao cisalhamento, resistência à flexão biaxial e microdureza das cerâmicas, a fim de investigar a influência do tempo de condicionamento do HF nas cerâmicas vítreas, incluindo feldspáticas, de silicato de lítio reforçada por zircônia e dissilicato de lítio. O condicionamento com HF por 60s é recomendado para cerâmicas feldspáticas, enquanto para cerâmicas de silicato de lítio reforçada por zircônia e de dissilicato de lítio é indicado por 20s. Conclusão: O tempo de condicionamento da cerâmica com HF influencia na adesão. Tempos prolongados de condicionamento são prejudiciais às cerâmicas vítreas, refletindo em redução da adesão protética.


Author(s):  
Alexandro Andrade ◽  
Thais Cristina Siqueira ◽  
Anderson D’Oliveira ◽  
Fábio Hech Dominski

The authors aimed to provide an overview of the evidence on the effects of exercise in people with Alzheimer’s disease through a comprehensive review of the existing systematic reviews and meta-analyses. A literature search was performed in CINAHL, Cochrane Library, EMBASE, PubMed, SPORTDiscus, Scopus, and Web of Science databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The AMSTAR-2-Tool was used for the quality assessment. Twenty-three reviews fulfilled the criteria. Most of the reviews investigated the effects of aerobic exercise on Alzheimer’s disease symptoms. The largest effects of exercise were seen in terms of improved cognition by multiple exercises. The majority of the reviews were rated as being of moderate quality and none were classified as having high quality. Exercise is an effective way to treat Alzheimer’s disease symptoms and has a low incidence of related adverse events. As most reviews were evaluated as low-moderate quality, caution is needed in the interpretation of the results.


Author(s):  
Simon Gruber ◽  
Porawit Kamnoedboon ◽  
Mutlu Özcan ◽  
Murali Srinivasan

2020 ◽  
Vol 11 (SPL3) ◽  
pp. 1371-1377
Author(s):  
Farhat Yaasmeen Sadique Basha ◽  
Venkatesh Kommi ◽  
Raj S S

There has been an increase in the incidence of complete edentulism among the elder patients. Complete dentures are the most common and preferred treatment of choice. Complete dentures help in masticatory function and restore the facial shape of the edentulous patients. Fabrication of the complete dentures is, therefore, a very important task for the clinician to ensure patient satisfaction. Errors may occur during the denture fabrication and these are called processing errors. It is a multifactorial process. The aim of the survey is to study the errors that occur during processing of a complete denture. It is a questionnaire based study conducted with a batch of 100 dental students. The questionnaire consisted of 16 questions focused on different fabrication techniques, timing, materials used, etc. by various students. The data collected was represented statistically and discussed. Dough technique was the most preferred method adopted by 39% of the students. Shorter curing cycles produced less defects, but majority of the students used longer cycles (41%). Most of them reported fractures (16%) and microporosities (11%) as defects. We can conclude that there are a few areas of error during the processing of dentures by the dental students. The incidence of these errors, however appears to be low. There is a scope for CAD/CAM complete dentures in the future to eliminate the possibilities of errors.


2016 ◽  
Vol 21 (6) ◽  
pp. 2007-2019 ◽  
Author(s):  
Murali Srinivasan ◽  
Yoann Cantin ◽  
Albert Mehl ◽  
Harald Gjengedal ◽  
Frauke Müller ◽  
...  

2020 ◽  
Vol 40 (3) ◽  
pp. 554-569 ◽  
Author(s):  
Judith J. de Vries ◽  
Charlotte J.M. Snoek ◽  
Dingeman C. Rijken ◽  
Moniek P.M. de Maat

Objective: Post-translational modifications of fibrinogen influence the occurrence and progression of thrombotic diseases. In this systematic review, we assessed the current literature on post-translational modifications of fibrinogen and their effects on fibrin formation and clot characteristics. Approach and Results: A systematic search of Medline, Embase, Cochrane Library, and Web of Science was performed to find studies reporting post-translational modifications of fibrinogen and the effects on clot formation and structure. Both in vitro studies and ex vivo studies using patient material were included. One hundred five articles were included, describing 11 different modifications of fibrinogen. For the best known and studied modifications, conclusions could be drawn about their effect on clot formation and structure. Oxidation, high levels of nitration, and glycosylation inhibit the rate of polymerization, resulting in dense clots with thinner fibers, while low levels of nitration increase the rate of polymerization. Glycation showed different results for polymerization, but fibrinolysis was found to be decreased, as a consequence of increased density and decreased permeability of clots. Acetylation also decreases the rate of polymerization but results in increased fiber diameters and susceptibility to fibrinolysis. Other modifications were studied less or contrasting results were found. Therefore, substantial gaps in the knowledge about the effect of post-translational modifications remain. Conclusions: Overall, post-translational modifications do affect clot formation and characteristics. More studies need to be performed to reveal the effects of all post-translational modifications and the effects on thrombotic diseases. Expanding the knowledge about modifications of fibrinogen can ultimately contribute to optimizing treatments for thrombotic diseases.


2021 ◽  
Vol 13 (4) ◽  
pp. e6850
Author(s):  
Elivelton Sousa Montelo ◽  
Pedro Victor de Andrade Braga ◽  
Antonio Emerson Sousa da Silva ◽  
Ludmilla Karen Brandão Lima de Matos

Objetivo: Analisar os efeitos das técnicas de Mobilização do Conceito Mulligan (MCM) na cervicalgia crônica em adultos. Métodos: Revisão sistemática através das recomendações do “Preferred Reporting Items for Systematic Reviews and Meta-Analyses” (PRISMA), incluindo apenas Ensaios Clínicos Randomizados (ECR) com técnicas de MCM em participantes de 18 a 59 anos com cervicalgia grau I-II, com intensidades de dor e/ou incapacidades avaliadas por instrumentos validados, somente artigos com textos completos nos idiomas inglês, português ou espanhol, entre  2015 a 2020, nas bases PubMed, Web of Science, Science Direct, Embase, Scopus, Cochrane Library e PEDro, foi realizada a análise dos títulos e a leitura dos resumos para verificar os que seriam avaliados na íntegra. Essa etapa foi realizada por três pesquisadores de forma independente. Aplicou-se a ferramenta da Cochrane para avaliar a qualidade metodológica e risco de vieses. Resultados: Dos 65 estudos identificados, após a análise dos critérios de elegibilidade, selecionou-se 4 artigos para a síntese qualitativa. Considerações finais: MCM associadas com outras condutas proporcionam melhora na dor e incapacidades e indivíduos tratados com SNAGS de forma isolada obtiveram melhoras no limiar de pressão de dor.


2019 ◽  
Vol 7 (11) ◽  
Author(s):  
Caroline Costa Tavares ◽  
Julliana Cariry Palhano Freire ◽  
Stéphanie Cariry Palhano Freire ◽  
Eduardo Dias-Ribeiro ◽  
André Ulisses Dantas Batista

Introdução: A tecnologia CAD/CAM possui múltiplas aplicações protéticas, incluindo a prótese total. Objetivos: realizar uma revisão de literatura sobre a aplicabilidade dos sistemas CAD/CAM na fabricação de próteses totais, a fim de elucidar as propriedades das próteses confeccionadas através dessa tecnologia e as características desse sistema. Metodologia: A busca por artigos científicos que contemplassem o tema foi realizada através das bases de dados PUBMED e SCIELO, sem restrição de período. Foi feita a análise dos títulos e resumos e em seguida o acesso ao texto completo. Resultados: Dentre as características do sistema CAD/CAM, os estudos citaram menor necessidade de consultas e tempo clínico. É preciso conhecimento da tecnologia pelo cirurgião-dentista e o maior custo laboratorial é uma das desvantagens de sua utilização. Quanto às propriedades, observa-se a redução da rugosidade e porosidade, assim como da adesão de Candida albicans à base da prótese e teor de monômero residual. Maior dureza de superfície é verificada em comparação com as próteses totais convencionais. Conclusão: Menor número de consultas e tempo clínico são características do uso do sistema CAD/CAM em prótese total. Maior dureza da prótese e redução da rugosidade, porosidade, adesão de C. albicanse do teor de monômero residual são propriedades que as próteses totais apresentam quando confeccionadas por essa tecnologia.Descritores: Odontologia; Prótese Total; Projeto Auxiliado por Computador.ReferênciasAlbero A, Pacual A, Camps I, Grau-Benitez M. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network. J Clin Exp Dent. 2015;7(4):e495-500.Janeva N, Kovacevska G, Janev E. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method. Open Access Macedonian Journal of Medical Sciences. 2017;5(6):785-89.Baba NZ, Alrumaih HS, Goodacre BJ, Goodacre CJ.  Current   techniques  in  CAD/CAM  denture fabrication. Gen Dent. 2016;64(6):23-8.Alamari MR. The influence of polishing techniques on pre-polymerized CAD/CAM acrylic resin denture bases. Electronic Physician. 2017;9(10):5452-58.Steinmassl PA, Klaunzer F, Steinmassi O, Dumfahrt H, Grunert I. Evaluation of Currently Available CAD/CAM Denture Systems. Int J Prosthodont. 2017;30(2):116-22.de Mendonça AF, Furtado de Mendonça M, White GS, Sara G, Littlefair D. Total CAD/CAM Supported Method for Manufacturing Removable Complete Dentures. Case Reports in Dentistry. 2016;2016:1259581.Mclaughlin JB, Ramos VJr. Complete denture fabrication with CAD/CAM record bases. J Prosthet Dent. 2015;114(4):493-97.Schweiger J, Guth JF, Edelhoff D, Stumbaum J. Virtual evaluation for CAD-CAM-fabricated complete dentures. J Prosthet Dent. 2017;117(1):28-33.Liu PR, Essig ME. Panorama of dental CAD/CAM restorative systems. Compend Contin Educ Dent. 2008; 29:482, 4, 6-8 passim.Giordano R. Materials for chairside CAD/CAM-produced restorations. J Am Dent Assoc. 2006;137(Suppl):14S-21S.Bilgin MS, Baytaroglu EN, Erdem A, Dilber E. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication. European Journal of Dentistry. 2016;10(2):286-91.Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont. 1994;7:17–21.Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: Preliminary results. J Periodontol. 2005;76:503–7.Ucar Y, Akova T, Aysan I. Mechanical properties of polyamide versus different PMMA denture base materials. J Prosthodont. 2012;21(3):173–6.Lee HJ, Kim CW, Kim YS. The level of residual monomer in injection molded denture base materials. J Korean Acad Prosth. 2003;41(3):360–8.Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc. 2013;41(6):407–16.Consani RLX, Pucciarelli MGR, Mesquita MF, Nogueira MC, Barao VA. Polymerisation cycles on hardness and surface gloss of denture base. Int J Contemp Dent Med Rev. 2014;2014:1–6.Nakayama M, Takagi N. Methods for manufacturing dental resin block. US:2016.Murakami N, Wakabayashi N, Matsushima R, Kishida A, Igarashi Y. Effect of high-pressure polymerization on mechanical properties of PMMA denture base resin. J Mech Behav Biomed Mater. 2013;20:98-104.Al-Fouzan AF, Al-Mejarad Lamya A, Albarrag AM. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures. J Adv Prosthodont. 2017;9(5):402-8.Digholkar S, Madhav VN, Palaskar J. Evaluation of the flexural strength and microhardness of provisional crown and bridge materials fabricated by different methods. J Indian Prosthodont Soc. 2016;16(4):328-34.Ayman AD. The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins. Electron Physician. 2017;9(7):4766-72.


Sign in / Sign up

Export Citation Format

Share Document