scholarly journals A Hybrid Approach for Cardiac Blood Flow Vortex Ring Identification Based on Optical Flow and Lagrangian Averaged Vorticity Deviation

2021 ◽  
Vol 12 ◽  
Author(s):  
Ke Yang ◽  
Shiqian Wu ◽  
Oluwarotimi W. Samuel ◽  
Hui Zhang ◽  
Dhanjoo N. Ghista ◽  
...  

Objective: The measurement of cardiac blood flow vortex characteristics can help to facilitate the analysis of blood flow dynamics that regulates heart function. However, the complexity of cardiac flow along with other physical limitations makes it difficult to adequately identify the dominant vortices in a heart chamber, which play a significant role in regulating the heart function. Although the existing vortex quantification methods can achieve this goal, there are still some shortcomings: such as low precision, and ignoring the center of the vortex without the description of vortex deformation processes. To address these problems, an optical flow Lagrangian averaged vorticity deviation (Optical flow-LAVD) method is proposed.Methodology: We examined the flow within the right atrium (RA) of the participants’ hearts, by using a single set of scans pertaining to a slice at two-chamber short-axis orientation. Toward adequate extraction of the vortex ring characteristics, a novel approach driven by the Lagrangian averaged vorticity deviation (LAVD) was implemented and applied to characterize the trajectory integral associated with vorticity deviation and the spatial mean of rings, by using phase-contrast magnetic resonance imaging (PC-MRI) datasets as a case study. To interpolate the time frames between every larger discrete frame and minimize the error caused by constructing a continuous velocity field for the integral process of LAVD, we implemented the optical flow as an interpolator and introduced the backward warping as an intermediate frame synthesis basis, which is then used to generate higher quality continuous velocity fields.Results: Our analytical study results showed that the proposed Optical flow-LAVD method can accurately identify vortex ring and continuous velocity fields, based on optical flow information, for yielding high reconstruction outcomes. Compared with the linear interpolation and phased-based frame interpolation methods, our proposed algorithm can generate more accurate synthesized PC-MRI.Conclusion: This study has developed a novel Optical flow-LAVD model to accurately identify cardiac vortex rings, and minimize the associated errors caused by the construction of a continuous velocity field. Our paper presents a superior vortex characteristics detection method that may potentially aid the understanding of medical experts on the dynamics of blood flow within the heart.

2019 ◽  
Author(s):  
Wentao Zhu ◽  
Yufang Huang ◽  
Mani A Vannan ◽  
Shizhen Liu ◽  
Daguang Xu ◽  
...  

AbstractEchocardiography has become routinely used in the diagnosis of cardiomyopathy and abnormal cardiac blood flow. However, manually measuring myocardial motion and cardiac blood flow from echocar-diogram is time-consuming and error-prone. Computer algorithms that can automatically track and quantify myocardial motion and cardiac blood flow are highly sought after, but have not been very successful due to noise and high variability of echocardiography. In this work, we propose a neural multi-scale self-supervised registration (NMSR) method for automated myocardial and cardiac blood flow dense tracking. NMSR incorporates two novel components: 1) utilizing a deep neural net to parameterize the velocity field between two image frames, and 2) optimizing the parameters of the neural net in a sequential multi-scale fashion to account for large variations within the velocity field. Experiments demonstrate that NMSR yields significantly better registration accuracy than the state-of-the-art methods, such as advanced normalization tools (ANTs) and Voxel Morph, for both myocardial and cardiac blood flow dense tracking. Our approach promises to provide a fully automated method for fast and accurate analyses of echocardiograms.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1205
Author(s):  
Ruiqi Wang ◽  
Riqiang Duan ◽  
Haijun Jia

This publication focuses on the experimental validation of film models by comparing constructed and experimental velocity fields based on model and elementary experimental data. The film experiment covers Kapitza numbers Ka = 278.8 and Ka = 4538.6, a Reynolds number range of 1.6–52, and disturbance frequencies of 0, 2, 5, and 7 Hz. Compared to previous publications, the applied methodology has boundary identification procedures that are more refined and provide additional adaptive particle image velocimetry (PIV) method access to synthetic particle images. The experimental method was validated with a comparison with experimental particle image velocimetry and planar laser induced fluorescence (PIV/PLIF) results, Nusselt’s theoretical prediction, and experimental particle tracking velocimetry (PTV) results of flat steady cases, and a good continuity equation reproduction of transient cases proves the method’s fidelity. The velocity fields are reconstructed based on different film flow model velocity profile assumptions such as experimental film thickness, flow rates, and their derivatives, providing a validation method of film model by comparison between reconstructed velocity experimental data and experimental velocity data. The comparison results show that the first-order weighted residual model (WRM) and regularized model (RM) are very similar, although they may fail to predict the velocity field in rapidly changing zones such as the front of the main hump and the first capillary wave troughs.


1991 ◽  
Vol 58 (3) ◽  
pp. 820-824 ◽  
Author(s):  
A. Bogobowicz ◽  
L. Rothenburg ◽  
M. B. Dusseault

A semi-analytical solution for plane velocity fields describing steady-state incompressible flow of nonlinearly viscous fluid into an elliptical opening is presented. The flow is driven by hydrostatic pressure applied at infinity. The solution is obtained by minimizing the rate of energy dissipation on a sufficiently flexible incompressible velocity field in elliptical coordinates. The medium is described by a power creep law and solutions are obtained for a range of exponents and ellipse eccentricites. The obtained solutions compare favorably with results of finite element analysis.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0247826
Author(s):  
Bård A. Bendiksen ◽  
Gary McGinley ◽  
Ivar Sjaastad ◽  
Lili Zhang ◽  
Emil K. S. Espe

Myocardial velocities carry important diagnostic information in a range of cardiac diseases, and play an important role in diagnosing and grading left ventricular diastolic dysfunction. Tissue Phase Mapping (TPM) Magnetic Resonance Imaging (MRI) enables discrete sampling of the myocardium’s underlying smooth and continuous velocity field. This paper presents a post-processing framework for constructing a spatially and temporally smooth and continuous representation of the myocardium’s velocity field from TPM data. In the proposed scheme, the velocity field is represented through either linear or cubic B-spline basis functions. The framework facilitates both interpolation and noise reducing approximation. As a proof-of-concept, the framework was evaluated using artificially noisy (i.e., synthetic) velocity fields created by adding different levels of noise to an original TPM data. The framework’s ability to restore the original velocity field was investigated using Bland-Altman statistics. Moreover, we calculated myocardial material point trajectories through temporal integration of the original and synthetic fields. The effect of noise reduction on the calculated trajectories was investigated by assessing the distance between the start and end position of material points after one complete cardiac cycle (end point error). We found that the Bland-Altman limits of agreement between the original and the synthetic velocity fields were reduced after application of the framework. Furthermore, the integrated trajectories exhibited consistently lower end point error. These results suggest that the proposed method generates a realistic continuous representation of myocardial velocity fields from noisy and discrete TPM data. Linear B-splines resulted in narrower limits of agreement between the original and synthetic fields, compared to Cubic B-splines. The end point errors were also consistently lower for Linear B-splines than for cubic. Linear B-splines therefore appear to be more suitable for TPM data.


IJARCCE ◽  
2015 ◽  
pp. 468-473
Author(s):  
Kazi Md. Shahiduzzaman ◽  
Khan Mamun Reza ◽  
Nusrat Tazin

2011 ◽  
Vol 4 (3) ◽  
pp. 1569-1610
Author(s):  
J. J. Fürst ◽  
O. Rybak ◽  
H. Goelzer ◽  
B. De Smedt ◽  
P. de Groen ◽  
...  

Abstract. We present a novel finite difference implementation of a three-dimensional higher-order ice sheet model that performs well both in terms of convergence rate and numerical stability. In order to achieve these benefits the discretisation of the governing force balance equation makes extensive use of information on staggered grid points. Using the same iterative solver, an existing discretisation that operates exclusively on the regular grid serves as a reference. Participation in the ISMIP-HOM benchmark indicates that both discretisations are capable of reproducing the higher-order model inter-comparison results. This allows a direct comparison not only of the resultant velocity fields but also of the solver's convergence behaviour which holds main differences. First and foremost, the new finite difference scheme facilitates convergence by a factor of up to 7 and 2.6 in average. In addition to this decrease in computational costs, the precision for the resultant velocity field can be chosen higher in the novel finite difference implementation. For high precisions, the old discretisation experiences difficulties to converge due to large variation in the velocity fields of consecutive Picard iterations. Finally, changing discretisation prevents build-up of local field irregularites that occasionally cause divergence of the solution for the reference discretisation. The improved behaviour makes the new discretisation more reliable for extensive application to real ice geometries. Higher precision and robust numerics are crucial in time dependent applications since numerical oscillations in the velocity field of subsequent time steps are attenuated and divergence of the solution is prevented. Transient applications also benefit from the increased computational efficiency.


2006 ◽  
Vol 652 (2) ◽  
pp. 1747-1754 ◽  
Author(s):  
Robin C. Colaninno ◽  
Angelos Vourlidas
Keyword(s):  

2013 ◽  
Vol 2013 ◽  
pp. 1-19 ◽  
Author(s):  
Daniel Carbunaru ◽  
Sabina Stefan ◽  
Monica Sasu ◽  
Victor Stefanescu

The mesoscale configurations are analysed associated withthesplitting process of convective cells responsible for severe weather phenomena in the south-eastern part of Romania. The analysis was performed using products from the S-band Doppler weather radar located in Medgidia. The cases studied were chosen to cover various synoptic configurations when the cell splitting process occurs. To detect the presence and intensity of the tropospheric jet, the Doppler velocity field and vertical wind profiles derived from radar algorithms were used. The relative Doppler velocity field was used to study relative flow associated with convective cells. Trajectories and rotational characteristics associated with convective cells were obtained from reflectivity and relative Doppler velocity fields at various elevations. This analysis highlights the main dynamic features associated with the splitting process of convective cells: the tropospheric jet and vertical moisture flow associated with the configuration of the flow relative to the convective cells for the lower and upper tropospheric layers. These dynamic characteristics seen in the Doppler based velocity field and in the relative Doppler velocity field to the storm can indicate further evolution of convective developments, with direct implications to very short range forecast (nowcasting).


Sign in / Sign up

Export Citation Format

Share Document