scholarly journals Association between the On-Plane Angular Motions of the Axle-Chain System and Clubhead Speed in Skilled Male Golfers

2020 ◽  
Vol 10 (17) ◽  
pp. 5728
Author(s):  
Morgan V. Madrid ◽  
Marco A. Avalos ◽  
Nicholas A. Levine ◽  
Noelle J. Tuttle ◽  
Kevin A. Becker ◽  
...  

The on-plane rotations of the inclined axle-chain system on the functional swing plane (FSP) can represent the angular motions of the golfer–club system closely. The purpose of this study was to identify key performance factors in golf through a comprehensive investigation of the association between the angular motion characteristics of the axle-chain system and clubhead speed in skilled golfers. Sixty-six male golfers (handicap ≤ 3) performed full-effort shots in three club conditions: driver, 5-iron, and pitching wedge. Swing trials were captured with an optical motion capture system, and the hip/shoulder lines, upper lever, club, and wrist angular positions/velocities were calculated. Time, angular position, range of rotation, and peak angular velocity parameters were extracted and their correlation coefficients (Pearson and Spearman) to actual and normalized clubhead speeds were computed (p < 0.05). Higher clubhead speed was associated with shorter downswing phases, larger rotation ranges (hip/shoulder lines, and upper lever), larger hip–shoulder separation at impact, delayed transitions (hip line and upper lever), faster rotations (backswing, downswing, and impact), and larger angular velocity losses (hip line and upper lever) with additional club- and body-specific correlations. Clubhead speed was not well associated with wrist cock angles/ranges, X-factors/stretches, and timings of the downswing peak.

Author(s):  
Gabriel Delgado-García ◽  
Jos Vanrenterghem ◽  
Emilio J Ruiz-Malagón ◽  
Pablo Molina-García ◽  
Javier Courel-Ibáñez ◽  
...  

Whereas 3D optical motion capture (OMC) systems are considered the gold standard for kinematic assessment in sport science, they present some drawbacks that limit its use in the field. Inertial measurement units (IMUs) incorporating gyroscopes have been considered as a more practical alternative. Thus, the aim of the study was to evaluate the level of agreement for angular velocity between IMU gyroscopes and an OMC system for varying tennis strokes and intensities. In total, 240 signals of angular velocity from different body segments and types of strokes (forehand, backhand and service) were recorded from four players (two competition players and two beginners). The angular velocity of the IMU gyroscopes was compared to the angular velocity from the OMC system. Level of agreement was evaluated by correlation coefficients, magnitudes of errors in absolute and relative values and Bland-Altman plots. Differences between both systems were highly consistent within players’ skill (i.e. along the broad range of velocities) and axes ( x, y, z). Correlations ranged from 0.951 to 0.993, indicating a very strong relationship and concordance. The magnitude of the differences ranged from 4.4 to 35.4 deg·s−1. The difference relative to the maximum angular velocity achieved was less than 5.0%. The study concluded that IMUs and OMC systems showed comparable values. Thus, IMUs seem to be a valid alternative to detect meaningful differences in angular velocity during tennis groundstrokes in field-based experimentation.


Sensors ◽  
2020 ◽  
Vol 20 (20) ◽  
pp. 5963 ◽  
Author(s):  
Elke Warmerdam ◽  
Robbin Romijnders ◽  
Julius Welzel ◽  
Clint Hansen ◽  
Gerhard Schmidt ◽  
...  

Neurological pathologies can alter the swinging movement of the arms during walking. The quantification of arm swings has therefore a high clinical relevance. This study developed and validated a wearable sensor-based arm swing algorithm for healthy adults and patients with Parkinson’s disease (PwP). Arm swings of 15 healthy adults and 13 PwP were evaluated (i) with wearable sensors on each wrist while walking on a treadmill, and (ii) with reflective markers for optical motion capture fixed on top of the respective sensor for validation purposes. The gyroscope data from the wearable sensors were used to calculate several arm swing parameters, including amplitude and peak angular velocity. Arm swing amplitude and peak angular velocity were extracted with systematic errors ranging from 0.1 to 0.5° and from −0.3 to 0.3°/s, respectively. These extracted parameters were significantly different between healthy adults and PwP as expected based on the literature. An accurate algorithm was developed that can be used in both clinical and daily-living situations. This algorithm provides the basis for the use of wearable sensor-extracted arm swing parameters in healthy adults and patients with movement disorders such as Parkinson’s disease.


2021 ◽  
Author(s):  
Kohei Yoshimoto ◽  
Masahiro Shinya

Obstacle crossing is a typical adaptive locomotion known to be related to the risk of falls. Previous conventional studies have used elaborate and costly optical motion capture systems, which not only represent a considerable expense but also require participants to visit a laboratory. To overcome these shortcomings, we aimed to develop a practical and inexpensive solution for measuring obstacle-crossing behavior by using the Microsoft Azure Kinect, one of the most promising markerless motion capture systems. We validated the Azure Kinect as a tool to measure foot clearance and compared its performance to that of an optical motion capture system (Qualisys). We also determined the effect of the Kinect sensor placement on measurement performance. Sixteen healthy young men crossed obstacles of different heights (50, 150, and 250 mm). Kinect sensors were placed in front of and beside the obstacle as well as diagonally between those positions. As indices of measurement quality, we counted the number of measurement failures and calculated the systematic and random errors between the foot clearance measured by the Kinect and Qualisys. We also calculated the Pearson correlation coefficients between the Kinect and Qualisys measurements. The number of measurement failures and the systematic and random error were minimized when the Kinect was placed diagonally in front of the obstacle on the same side as the trail limb. The high correlation coefficient (r > 0.890) observed between the Kinect and Qualisys measurements suggests that the Azure Kinect has excellent potential for measuring foot clearance during obstacle-crossing tasks.


2018 ◽  
Vol 140 (4) ◽  
Author(s):  
Laura Hutchinson ◽  
Joel B. Schwartz ◽  
Amy M. Morton ◽  
Irene S. Davis ◽  
Kevin J. Deluzio ◽  
...  

When optical motion capture is used for motion analysis, reflective markers or a digitizer are typically used to record the location of anatomical landmarks identified through palpation. The landmarks are then used to construct anatomical coordinate systems. Failure to consistently identify landmarks through palpation over repeat tests creates artifacts in the kinematic waveforms. The purpose of this work was to improve intra- and inter-rater reliability in determining lower limb anatomical landmarks and the associated anatomical coordinate systems using a marker alignment device (MAD). The device aids the subject in recreating the same standing posture over multiple tests, and recreates the anatomical landmarks from previous static calibration trials. We tested three different raters who identified landmarks on eleven subjects. The subjects performed walking trials and their gait kinematics were analyzed with and without the device. Ankle kinematics were not improved by the device suggesting manual palpation over repeat visits is just as effective as the MAD. Intra-class correlation coefficients between gait kinematics registered to the reference static trial and registered to follow-up static trials with and without the device were improved between 1% and 33% when the device was used. Importantly, out-of-plane hip and knee kinematics showed the greatest improvements in repeatability. These results suggest that the device is well suited to reducing palpation artifact during repeat visits to the gait lab.


Author(s):  
Taisuke Ito ◽  
Yuichi Ota

AYUMI EYE is an accelerometer-based gait analysis device that measures the 3D accelerations of the human trunk. This study investigated the measurement accuracy of the AYUMI EYE as hardware as well as the accuracy of the gait cycle extraction program via simultaneous measurements using AYUMI EYE, a ground reaction force (GRF), and an optical motion capture system called VICON. The study was conducted with four healthy individuals as participants. The gait data were obtained by simulating four different patterns for three trials each: normal walking, anterior-tilt walking, hemiplegic walking, and shuffling walking. The AYUMI EYE and VICON showed good agreement for both the acceleration and displacement data. The durations of subsequent stride cycles calculated using the AYUMI EYE and GRF were in good agreement based on the calculated cross-correlation coefficients (CCs) with an r value of 0.896 and p-value less than 0.05, and their accuracies for these results were sufficient.


2021 ◽  
Vol 37 (6) ◽  
pp. 619-628
Author(s):  
Young-Hoo Kwon ◽  
Noelle J. Tuttle ◽  
Cheng-Ju Hung ◽  
Nicholas A. Levine ◽  
Seungho Baek

The purpose of this study was to investigate the linear relationships among the hand/clubhead motion characteristics in golf driving in skilled male golfers (n = 66; handicap ≤ 3). The hand motion plane (HMP) and functional swing plane (FSP) angles, the HMP–FSP angle gaps, the planarity characteristics of the off-plane motion of the clubhead, and the attack angles were computed from the drives captured by an optical motion capture system. The HMP angles were identified as the key variables, as the HMP and FSP angles were intercorrelated, but the plane angle gaps, the planarity bias, and the attack angles showed correlations to the HMP angles primarily. Three main swing pattern clusters were identified. The parallel HMP–FSP alignment pattern with a small direction gap was associated with neutral planarity and planar swing pattern. The inward alignment pattern with a large inward direction gap was characterized by flat planes, follow-through-centric planarity, spiral swing pattern, and inward/downward impact. The outward alignment pattern with a large outward direction gap was associated with steep planes, downswing-centric planarity, reverse spiral swing, and outward/upward impact. The findings suggest that practical drills targeting the hand motion pattern can be effective in holistically reprogramming the swing pattern.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2869
Author(s):  
Jiaen Wu ◽  
Kiran Kuruvithadam ◽  
Alessandro Schaer ◽  
Richie Stoneham ◽  
George Chatzipirpiridis ◽  
...  

The deterioration of gait can be used as a biomarker for ageing and neurological diseases. Continuous gait monitoring and analysis are essential for early deficit detection and personalized rehabilitation. The use of mobile and wearable inertial sensor systems for gait monitoring and analysis have been well explored with promising results in the literature. However, most of these studies focus on technologies for the assessment of gait characteristics, few of them have considered the data acquisition bandwidth of the sensing system. Inadequate sampling frequency will sacrifice signal fidelity, thus leading to an inaccurate estimation especially for spatial gait parameters. In this work, we developed an inertial sensor based in-shoe gait analysis system for real-time gait monitoring and investigated the optimal sampling frequency to capture all the information on walking patterns. An exploratory validation study was performed using an optical motion capture system on four healthy adult subjects, where each person underwent five walking sessions, giving a total of 20 sessions. Percentage mean absolute errors (MAE%) obtained in stride time, stride length, stride velocity, and cadence while walking were 1.19%, 1.68%, 2.08%, and 1.23%, respectively. In addition, an eigenanalysis based graphical descriptor from raw gait cycle signals was proposed as a new gait metric that can be quantified by principal component analysis to differentiate gait patterns, which has great potential to be used as a powerful analytical tool for gait disorder diagnostics.


Sign in / Sign up

Export Citation Format

Share Document