scholarly journals Variation of Passive Biomechanical Properties of the Small Intestine along Its Length: Microstructure-Based Characterization

2021 ◽  
Vol 8 (3) ◽  
pp. 32
Author(s):  
Dimitrios P. Sokolis

Multiaxial testing of the small intestinal wall is critical for understanding its biomechanical properties and defining material models, but limited data and material models are available. The aim of the present study was to develop a microstructure-based material model for the small intestine and test whether there was a significant variation in the passive biomechanical properties along the length of the organ. Rat tissue was cut into eight segments that underwent inflation/extension testing, and their nonlinearly hyper-elastic and anisotropic response was characterized by a fiber-reinforced model. Extensive parametric analysis showed a non-significant contribution to the model of the isotropic matrix and circumferential-fiber family, leading also to severe over-parameterization. Such issues were not apparent with the reduced neo-Hookean and (axial and diagonal)-fiber family model, that provided equally accurate fitting results. Absence from the model of either the axial or diagonal-fiber families led to ill representations of the force- and pressure-diameter data, respectively. The primary direction of anisotropy, designated by the estimated orientation angle of diagonal-fiber families, was about 35° to the axial direction, corroborating prior microscopic observations of submucosal collagen-fiber orientation. The estimated model parameters varied across and within the duodenum, jejunum, and ileum, corroborating histologically assessed segmental differences in layer thicknesses.

2021 ◽  
Vol 2 ◽  
Author(s):  
Nikolaos Papadimas ◽  
Timothy Dodwell

Abstract This article recasts the traditional challenge of calibrating a material constitutive model into a hierarchical probabilistic framework. We consider a Bayesian framework where material parameters are assigned distributions, which are then updated given experimental data. Importantly, in true engineering setting, we are not interested in inferring the parameters for a single experiment, but rather inferring the model parameters over the population of possible experimental samples. In doing so, we seek to also capture the inherent variability of the material from coupon-to-coupon, as well as uncertainties around the repeatability of the test. In this article, we address this problem using a hierarchical Bayesian model. However, a vanilla computational approach is prohibitively expensive. Our strategy marginalizes over each individual experiment, decreasing the dimension of our inference problem to only the hyperparameter—those parameter describing the population statistics of the material model only. Importantly, this marginalization step, requires us to derive an approximate likelihood, for which, we exploit an emulator (built offline prior to sampling) and Bayesian quadrature, allowing us to capture the uncertainty in this numerical approximation. Importantly, our approach renders hierarchical Bayesian calibration of material models computational feasible. The approach is tested in two different examples. The first is a compression test of simple spring model using synthetic data; the second, a more complex example using real experiment data to fit a stochastic elastoplastic model for 3D-printed steel.


Author(s):  
Jennifer M. Bastiaan ◽  
Amir Khajepour

A physical testing program is performed in support of finite element model creation for a 50-series passenger car tire. ABAQUS finite element analysis software is used along with its standard material models. Uniaxial tension testing of tire samples cut from the tread composite, tread rubber and sidewall composite is performed in order to obtain material properties. Hyper-elastic material coefficients for tread rubber are fit using uniaxial tension test data. Results show that the Arruda-Boyce hyper-elastic material model fits the test data well and it predicts reasonable overall behavior in uniaxial tension and uniaxial compression. Most other hyperelastic material models are found to predict unrealistic behavior in uniaxial compression for the tire samples, especially in the 0 to 20% compressive strain range. Frequency response testing of two inflated passenger car tires of different sizes, makes and models is also performed to assist in defining the viscoelastic material model for tread rubber. Test results show that tire modal damping is in the 2 to 4% range for most modes below 200 Hz, and the response curves, modal density and modal damping are remarkably similar for the two tires tested. The tire finite element model with updated material properties is simulated for nine combinations of air inflation pressure and vertical load in order to calculate static loaded radius. The analysis results are compared with physical test results and the analysis results are found to deviate at most by 3% compared to the tests.


2014 ◽  
Vol 905 ◽  
pp. 161-166
Author(s):  
Zoltan Major ◽  
Matei C. Miron ◽  
Umut D. Cakmak

Different grades of several thermoplastic elastomer types were selected and are investigated over a wide frequency/time, temperature and loading range in a research project of the authors. Relevant material models are selected for different loading situations and based on these experimental data the material model parameters were determined either directly or by applying fitting procedures. These models along with the proper data were used for modeling the deformation and the failure behavior of typical engineering thermoplastic elastomer components. Furthermore, based on the modeling of various elastomers under different service relevant loading situation several design proposals were formulated.


2003 ◽  
Vol 125 (2) ◽  
pp. 266-273 ◽  
Author(s):  
Yanling Dou ◽  
Jingbo Zhao ◽  
Hans Gregersen

The stress-strain relationship is determined by the inherent mechanical properties of the intestinal wall, the geometric configurations, the loading conditions and the zero-stress state of the segment. The purpose of this project was to provide morphometric and biomechanical data for rat duodenum, jejunum and ileum. The circumferential strains were referenced to the zero-stress state. Large morphometric variations were found along the small intestine with an increase in the outer circumferential length and luminal area and a decrease in wall thickness in distal direction. The serosal residual strain was tensile and decreased in distal direction P<0.05. The mucosal residual strain was compressive and the absolute value decreased in distal direction P<0.001. The stress-strain experiments showed that the duodenum was stiffest. All segments were stiffest in longitudinal direction P<0.05. In conclusion, axial variation in morphometric and biomechanical properties was found in the small intestine. The zero-stress state must be considered in future biomechanical studies in the gastrointestinal tract.


2015 ◽  
Vol 1 (1) ◽  
pp. 442-445 ◽  
Author(s):  
T. Reuter ◽  
I. Ponomarev

AbstractThe biomechanical properties are crucial indicators for the functional characterization of cartilaginous tissue. In this contribution native articular cartilage and three-dimensional scaffold-free cartilage constructs (SFCCs) are characterized by hyperelastic material models (Yeoh, Ogden and Demiray). SFCCs were developed for the therapy of damaged articular cartilage. The normalized error (NE) of fit and experiment is in the range of 0.04 and 0.13. The material model Yeoh with two parameters yields the best fit. The stress-like parameterc20 is 0.489 MPa for native cartilage, 0.120 MPa and 0.041 MPa for SFCCs produced from mesenchymal stem cells and chondrocytes, respectively. The significance of the fits and the derived parameters are presented and evaluated.


Author(s):  
D. Kamalakannan ◽  
V. Arun Baskar ◽  
B. Prabu

The material behaviour of elastomers can be simulated through Strain Energy Density (SED) function which can be defined by the following hyper plastic material models: (i) Neo-Hookean, (ii) Mooney-Rivlin, (iii) Yeoh and (iv) Ogden. The stress-strain relations of the above-mentioned SED functions for uni-axial tension, planar (pure shear) tension and equi-biaxial tension are validated with Treloar’s data. Different combinations of Treloar’s data are used to determine the co-efficient of SED functions of the above said models. These co-efficient values are determined using the software like ANSYS, MATLAB and POLYMATH and the validation of the results is carried out based on sum of squared error (SSE) which is calculated between the experimental values and predicted values. From the result, it is found that SSE less than 5 and closer to 0 can be taken as good prediction for selection of material model and co-efficient of material models. The engineering stress-strain behaviour of synthetic rubber (NBR) is obtained experimentally from uni-axial tension test and the co-efficient of SED functions are determined.


Author(s):  
А.А. Коваленко ◽  
Г.П. Титова ◽  
В.К. Хугаева

Оперативное лечение различных заболеваний кишечника сопровождается осложнениями в виде нарушений микроциркуляции в области анастомоза кишки. Ранее нами показана способность лимфостимуляторов пептидной природы восстанавливать нарушенную микроциркуляцию, что послужило основой для настоящего исследования. Цель работы - оценка влияния стимуляции лимфотока в стенке кишки на процессы восстановления микроциркуляции, структуры и функции тонкой кишки в области оперативного вмешательства. Методика. В экспериментах на наркотизированных крысах (хлоралгидрат в дозе 0,6 г/кг в 0,9% растворе NaCl) моделировали различные поражения тонкой кишки (наложение лигатуры, перевязка 1-3 брыжеечных артерий, перекрут петли кишки вокруг оси брыжейки, сочетание нескольких видов повреждений). Резекция поврежденного участка через 1 сут. с последующим созданием тонкокишечного анастомоза завершалась орошением операционного поля раствором пептида-стимулятора лимфотока (40 мкг/кг массы животного в 1 мл 0,9% раствора NaCl). На 7-е сут. после операции проводили гистологическое исследование фрагмента кишки в области анастомоза. Результаты. На 7-е сут. после резекции у выживших животных (летальность вследствие кишечной непроходимости составляла 30%) имеют место морфологические признаки острых сосудистых нарушений стенки кишки, изменений кровеносных и лимфатических микрососудов, интерстициальный отек всех слоев стенки кишки, дилатация просвета кишки, повреждение всасывающего эпителия ворсин с истончением щеточной каемки клеток, морфологические признаки гиперфункции бокаловидных клеток. Использование лимфостимулятора пептидной природы после операции увеличивало выживаемость животных на 24%. У части животных отмечалось уменьшение расширения просвета кишки, у других практически полная его нормализация. Восстанавливалась форма кишечных ворсин и распределение бокаловидных клеток. Отсутствовали признаки внутриклеточного и межмышечного отека. Отмечено умеренное полнокровие венул. Заключение. Использование лимфостимулятора при хирургическом лечении кишечной непроходимости увеличивает выживаемость животных на 24% по сравнению с контролем, способствует более раннему восстановлению структуры и функции тонкой кишки. Полученные результаты свидетельствуют о перспективности использования стимуляции лимфотока при операциях на кишечнике. Surgical treatment of bowel diseases is associated with complications that cause microcirculatory disturbances in the anastomosis area and may lead to a fatal outcome. This study was based on our previous finding that peptide-type lymphatic stimulators are able to restore impaired microcirculation. The aim of this work was stimulating the lymph flow in the intestinal wall to facilitate recovery of microcirculation, structure and function of the small intestine in the area of surgical intervention. Methods. In experiments on anesthetized rats (0.6 g/kg chloral hydrate in 0.9% NaCl), various small bowel lesions were modeled (bowel ligation, ligation of 1-3 mesenteric arteries, gut torsion, combination of several lesion types). In 24 h, the damaged area was resected, and a small intestine anastomosis was creased. The surgery was completed with irrigation of the operative field with a solution of lymph flow stimulating peptide (40 мg/kg body weight in 1 ml of 0.9% NaCl). A gut fragment from the anastomosis area was examined histologically on day 7 after the surgery. Results. On the 7th day after removing the intestinal obstruction, the surviving animals (lethality 30%) had morphological signs of acute vascular disorders in the intestinal wall; changes in blood and lymphatic microvessels; interstitial edema of all intestinal wall layers; dilatation of the intestinal lumen; damage to the absorptive epithelium of villi with thinning of the brush border, and hyperfunction of mucous (goblet) cells. The use of the peptide after surgery increased the survival rate of animals by 24% and provided a smaller dilatation of the intestinal lumen in some animals. In other animals, the lumen recovered. The shape of intestinal villi and distribution of goblet cells were restored. Signs of intracellular and intermuscular edema were absent. Moderate venular congestion was noticed. Conclusion. Using the lymphatic stimulator in surgical treatment of intestinal obstruction increases the survival rate of animals by 24% compared to the control, facilitates earlier restoration of the small intestine structure and function. The obtained results indicated the effectiveness of lymphatic stimulation in intestinal surgery.


2020 ◽  
Vol 20 (4) ◽  
Author(s):  
Łukasz Smakosz ◽  
Ireneusz Kreja ◽  
Zbigniew Pozorski

Abstract The current report is devoted to the flexural analysis of a composite structural insulated panel (CSIP) with magnesium oxide board facings and expanded polystyrene (EPS) core, that was recently introduced to the building industry. An advanced nonlinear FE model was created in the ABAQUS environment, able to simulate the CSIP’s flexural behavior in great detail. An original custom code procedure was developed, which allowed to include material bimodularity to significantly improve the accuracy of computational results and failure mode predictions. Material model parameters describing the nonlinear range were identified in a joint analysis of laboratory tests and their numerical simulations performed on CSIP beams of three different lengths subjected to three- and four-point bending. The model was validated by confronting computational results with experimental results for natural scale panels; a good correlation between the two results proved that the proposed model could effectively support the CSIP design process.


Author(s):  
Marvin Hardt ◽  
Thomas Bergs

AbstractAnalyzing the chip formation process by means of the finite element method (FEM) is an established procedure to understand the cutting process. For a realistic simulation, different input models are required, among which the material model is crucial. To determine the underlying material model parameters, inverse methods have found an increasing acceptance within the last decade. The calculated model parameters exhibit good validity within the domain of investigation, but suffer from their non-uniqueness. To overcome the drawback of the non-uniqueness, the literature suggests either to enlarge the domain of experimental investigations or to use more process observables as validation parameters. This paper presents a novel approach merging both suggestions: a fully automatized procedure in conjunction with the use of multiple process observables is utilized to investigate the non-uniqueness of material model parameters for the domain of cutting simulations. The underlying approach is two-fold: Firstly, the accuracy of the evaluated process observables from FE simulations is enhanced by establishing an automatized routine. Secondly, the number of process observables that are considered in the inverse approach is increased. For this purpose, the cutting force, cutting normal force, chip temperature, chip thickness, and chip radius are taken into account. It was shown that multiple parameter sets of the material model can result in almost identical simulation results in terms of the simulated process observables and the local material loads.


2012 ◽  
Vol 02 (01) ◽  
pp. 45-47
Author(s):  
Shetty K. Padma ◽  
Harish S. Permi ◽  
C.N. Patil ◽  
Michelle Mathias

AbstractSarcomatoid carcinoma occurring in the small intestine is very rare. They can be monophasic or biphasic. We report a rare case of monophasic Sarcomatoid carcinoma of the small intestine in a 60 year old male patient. The tumor was an ulceronodular mass involving the ileum circumferentially. The tumor infiltrated the full thickness of the intestinal wall and the serosa of an adjacent loop of ileum. Microscopically, the tumor was composed of sheets of malignant spindle cells. The carcinomatous nature of the tumor was evident only after Immunohistochemistry. The diagnosis of sarcomatoid carcinoma should be considered in the differential diagnosis of malignant spindle cell tumor of small intestine and immunohistochemical stains are required for the correct diagnosis.


Sign in / Sign up

Export Citation Format

Share Document