scholarly journals Validation of Copy Number Variants Detection from Pregnant Plasma Using Low-Pass Whole-Genome Sequencing in Noninvasive Prenatal Testing-Like Settings

Diagnostics ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 569
Author(s):  
Michaela Hyblova ◽  
Maria Harsanyova ◽  
Diana Nikulenkov-Grochova ◽  
Jitka Kadlecova ◽  
Marcel Kucharik ◽  
...  

Detection of copy number variants as an integral part of noninvasive prenatal testing is increasingly used in clinical practice worldwide. We performed validation on plasma samples from 34 pregnant women with known aberrations using cell-free DNA sequencing to evaluate the sensitivity for copy number variants (CNV) detection using an in-house CNV fraction-based detection algorithm. The sensitivity for CNVs smaller than 3 megabases (Mb), larger than 3Mb, and overall was 78.57%, 100%, and 90.6%, respectively. Regarding the fetal fraction, detection sensitivity in the group with a fetal fraction of less than 10% was 57.14%, whereas there was 100% sensitivity in the group with fetal fraction exceeding 10%. The assay is also capable of indicating whether the origin of an aberration is exclusively fetal or fetomaternal/maternal. This validation demonstrated that a CNV fraction-based algorithm was applicable and feasible in clinical settings as a supplement to testing for common trisomies 21, 18, and 13.

2020 ◽  
Author(s):  
Marcel Kucharik ◽  
Jaroslav Budis ◽  
Michaela Hyblova ◽  
Gabriel Minarik ◽  
Tomas Szemes

Copy number variations (CNVs) are a type of structural variant involving alterations in the number of copies of specific regions of DNA, which can either be deleted or duplicated. CNVs contribute substantially to normal population variability; however, abnormal CNVs cause numerous genetic disorders. Nowadays, several methods for CNV detection are used, from the conventional cytogenetic analysis through microarray-based methods (aCGH) to next-generation sequencing (NGS). We present GenomeScreen - NGS based CNV detection method based on a previously described CNV detection algorithm used for non-invasive prenatal testing (NIPT). We determined theoretical limits of its accuracy and confirmed it with extensive in-silico study and already genotyped samples. Theoretically, at least 6M uniquely mapped reads are required to detect CNV with a length of 100 kilobases (kb) or more with high confidence (Z-score > 7). In practice, the in-silico analysis showed the requirement at least 8M to obtain >99% accuracy (for 100 kb deviations). We compared GenomeScreen with one of the currently used aCGH methods in diagnostic laboratories, which has a 200 kb mean resolution. GenomeScreen and aCGH both detected 59 deviations, GenomeScreen furthermore detected 134 other (usually) smaller variations. Furthermore, the overall cost per sample is about 2-3x lower in the case of GenomeScreen.


2021 ◽  
Author(s):  
Jing He ◽  
Xuan Feng ◽  
Xing Wang ◽  
Qinghua Zhang ◽  
Lei Zheng ◽  
...  

Abstract Background: Noninvasive prenatal testing (NIPT) is based on second-generation genomic sequencing technology to scan cell-free fetal DNA originating from the placenta in maternal plasma. As the depth of sequencing increases, it can be used to focus on chromosomal aneuploidies, copy number variants (CNVs), and monogenic diseases. It can significantly improve the accuracy of prenatal screening and reduces the number of invasive testing.Methods: In this study, we retrospectively analyzed 16128 naturally conceived singleton pregnancies who underwent expanded NIPT to calculate the true positive rate (TPR) of chromosomal aneuploidies and CNVs, and analyzed the potential influence of maternal sex chromosome abnormalities (SCAs) and maternal CNVs on expanded NIPT results.Results: After invasive prenatal diagnosis and follow-up, 103 pregnancies were found to be true-positive, including 73 cases of chromosomal abnormalities and 30 cases of CNVs. The TPR of T21 was 84.62%, T18 was 50.00%, T13 was 22.22%, SCA was 34.06%, and CNVs was 40.28%. In addition, we found that the positive rate of aneuploidies increased with maternal age and that maternal SCAs accounted for 13.33% of the 60 false positive cases of SCAs.Conclusion: Expanded NIPT showed high sensitivity and specificity in detecting diseases of chromosomal abnormalities. It also shows good performance in detecting CNVs, but maternal SCAs and CNVs confused some NIPT results, indicating it is still necessary to study the potential maternal influence on expanded NIPT results and to report related clinical validation studies.


Genes ◽  
2020 ◽  
Vol 12 (1) ◽  
pp. 26
Author(s):  
Zhaochen Bai ◽  
Hu Zhao ◽  
Shaobin Lin ◽  
Linhuan Huang ◽  
Zhiming He ◽  
...  

As a novel type of genetic marker, the microhaplotype has shown promising potential in forensic research. In the present study, we analyzed maternal plasma cell-free DNA (cfDNA) samples from twin pregnancies to validate microhaplotype-based noninvasive prenatal testing (NIPT) for paternity, zygosity, and fetal fraction (FF). Paternity was determined with the combined use of the relMix package, zygosity was evaluated by examining the presence of informative loci with two fetal genome complements, and FF was assessed through fetal allele ratios. Paternity was determined in 19 twin cases, among which 13 cases were considered dizygotic (DZ) twins based on the presence of 3~10 informative loci and the remaining 6 cases were considered monozygotic (MZ) twins because no informative locus was observed. With the fetal genomic genotypes as a reference, the accuracy of paternity and zygosity determination were confirmed by standard short tandem repeat (STR) analysis. Moreover, the lower FF, higher FF, and combined FF in each DZ plasma sample were closely related to the estimated value. This present preliminary study proposes that microhaplotype-based NIPT is applicable for paternity, zygosity, and FF determination in twin pregnancies, which are expected to be advantageous for both forensic and clinical settings.


2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Yunsheng Ge ◽  
Jia Li ◽  
Jianlong Zhuang ◽  
Jian Zhang ◽  
Yanru Huang ◽  
...  

Abstract Background Noninvasive prenatal testing (NIPT) has been wildly used to screen for common aneuplodies. In recent years, the test has been expanded to detect rare autosomal aneuploidies (RATs) and copy number variations (CNVs). This study was performed to investigate the performance of expanded noninvasive prenatal testing (expanded NIPT) in screening for common trisomies, sex chromosomal aneuploidies (SCAs), rare autosomal aneuploidies (RATs), and copy number variations (CNVs) and parental willingness for invasive prenatal diagnosis in a Chinese prenatal diagnosis center. Methods A total of 24,702 pregnant women were retrospectively analyzed at the Women and Children’s Hospital from January 2013 to April 2019, among which expanded NIPT had been successfully conducted in 24,702 pregnant women. The high-risk expanded NIPT results were validated by karyotype analysis and chromosomal microarray analysis. All the tested pregnant women were followed up for pregnancy outcomes. Results Of the 24,702 cases, successful follow-up was conducted in 98.77% (401/446) of cases with common trisomies and SCAs, 91.95% (80/87) of RAT and CNV cases, and 76.25% (18,429/24,169) of cases with low-risk screening results. The sensitivity of expanded NIPT was 100% (95% confidence interval[CI], 97.38–100%), 96.67%(95%CI, 82.78–99.92%), and 100%(95%CI, 66.37–100.00%), and the specificity was 99.92%(95%CI, 99.87–99.96%), 99.96%(95%CI, 99.91–99.98%), and 99.88% (95%CI, 99.82–99.93%) for the detection of trisomies 21, 18, and 13, respectively. Expanded NIPT detected 45,X, 47,XXX, 47,XXY, XYY syndrome, RATs, and CNVs with positive predictive values of 25.49%, 75%, 94.12%, 76.19%, 6.45%, and 50%, respectively. The women carrying fetuses with Trisomy 21/Trisomy 18/Trisomy 13 underwent invasive prenatal diagnosis and terminated their pregnancies at higher rates than those at high risk for SCAs, RATs, and CNVs. Conclusions Our study demonstrates that the expanded NIPT detects fetal trisomies 21, 18, and 13 with high sensitivity and specificity. The accuracy of detecting SCAs, RATs, and CNVs is still relatively poor and needs to be improved. With a high-risk expanded NIPT result, the women at high risk for common trisomies are more likely to undergo invasive prenatal diagnosis procedures and terminate their pregnancies than those with unusual chromosome abnormalities.


2019 ◽  
Author(s):  
Junhua Rao ◽  
Lihua Peng ◽  
Fang Chen ◽  
Hui Jiang ◽  
Chunyu Geng ◽  
...  

AbstractBackgroundNext-generation sequence (NGS) has rapidly developed in past years which makes whole-genome sequencing (WGS) becoming a more cost- and time-efficient choice in wide range of biological researches. We usually focus on some variant detection via WGS data, such as detection of single nucleotide polymorphism (SNP), insertion and deletion (Indel) and copy number variant (CNV), which playing an important role in many human diseases. However, the feasibility of CNV detection based on WGS by DNBSEQ™ platforms was unclear. We systematically analysed the genome-wide CNV detection power of DNBSEQ™ platforms and Illumina platforms on NA12878 with five commonly used tools, respectively.ResultsDNBSEQ™ platforms showed stable ability to detect slighter more CNVs on genome-wide (average 1.24-fold than Illumina platforms). Then, CNVs based on DNBSEQ™ platforms and Illumina platforms were evaluated with two public benchmarks of NA12878, respectively. DNBSEQ™ and Illumina platforms showed similar sensitivities and precisions on both two benchmarks. Further, the difference between tools for CNV detection was analyzed, and indicated the selection of tool for CNV detection could affected the CNV performance, such as count, distribution, sensitivity and precision.ConclusionThe major contribution of this paper is providing a comprehensive guide for CNV detection based on WGS by DNBSEQ™ platforms for the first time.


2014 ◽  
Author(s):  
Sean D Smith ◽  
Joseph K Kawash ◽  
Andrey Grigoriev

Amplifications or deletions of genome segments, known as copy number variants (CNVs), have been associated with many diseases. Read depth analysis of next-generation sequencing (NGS) is an essential method of detecting CNVs. However, genome read coverage is frequently distorted by various biases of NGS platforms, which reduce predictive capabilities of existing approaches. Additionally, the use of read depth tools has been somewhat hindered by imprecise breakpoint identification. We developed GROM-RD, an algorithm that analyzes multiple biases in read coverage to detect CNVs in NGS data. We found non-uniform variance across distinct GC regions after using existing GC bias correction methods and developed a novel approach to normalize such variance. Although complex and repetitive genome segments complicate CNV detection, GROM-RD adjusts for repeat bias and uses a two-pipeline masking approach to detect CNVs in complex and repetitive segments while improving sensitivity in less complicated regions. To overcome a typical weakness of RD methods, GROM-RD employs a CNV search using size-varying overlapping windows to improve breakpoint resolution. We compared our method to two widely used programs based on read depth methods, CNVnator and RDXplorer, and observed improved CNV detection and breakpoint accuracy for GROM-RD. GROM-RD is available at http://grigoriev.rutgers.edu/software/


BioTechniques ◽  
2020 ◽  
Author(s):  
Luca Bedon ◽  
Josef Vuch ◽  
Simeone Dal Monego ◽  
Germana Meroni ◽  
Vanna Pecile ◽  
...  

The discovery of circulating fetal DNA in the plasma of pregnant women has greatly promoted advances in noninvasive prenatal testing. Screening performance is enhanced with higher fetal fraction and analysis of samples whose fetal DNA fraction is lower than 4% are unreliable. Although current approaches to fetal fraction measurement are accurate, most of them are expensive and time consuming. Here we present a simple and cost-effective solution that provides a quick and reasonably accurate fetal fraction by directly evaluating the size distribution of circulating DNA fragments in the extracted maternal cell-free DNA. The presented approach could be useful in the presequencing stage of noninvasive prenatal testing to evaluate whether the sample is suitable for the test or a repeat blood draw is recommended.


Sign in / Sign up

Export Citation Format

Share Document