scholarly journals Numerical Investigations of the Effects of the Rotating Shaft and Optimization of Urban Vertical Axis Wind Turbines

Energies ◽  
2018 ◽  
Vol 11 (7) ◽  
pp. 1870 ◽  
Author(s):  
Lidong Zhang ◽  
Kaiqi Zhu ◽  
Junwei Zhong ◽  
Ling Zhang ◽  
Tieliu Jiang ◽  
...  

The central shaft is an important and indispensable part of a small scale urban vertical axis wind turbines (VAWTs). Normally, it is often operated at the same angular velocity as the wind turbine. The shedding vortices released by the rotating shaft have a negative effect on the blades passing the wake of the wind shaft. The objective of this study is to explore the influence of the wake of rotating shaft on the performance of the VAWT under different operational and physical parameters. The results show that when the ratio of the shaft diameter to the wind turbine diameter (α) is 9%, the power loss of the wind turbine in one revolution increases from 0% to 25% relative to that of no-shaft wind turbine (this is a numerical experiment for which the shaft of the VAWT is removed in order to study the interactions between the shaft and blade). When the downstream blades pass through the wake of the shaft, the pressure gradient of the suction side and pressure side is changed, and an adverse effect is also exerted on the lift generation in the blades. In addition, α = 5% is a critical value for the rotating shaft wind turbine (the lift-drag ratio trend of the shaft changes differently). In order to figure out the impacts of four factors; namely, tip speed ratios (TSRs), α, turbulence intensity (TI), and the relative surface roughness value (ks/ds) on the performance of a VAWT system, the Taguchi method is employed in this study. The influence strength order of these factors is featured by TSRs > ks/ds > α > TI. Furthermore, within the range we have analyzed in this study, the optimal power coefficient (Cp) occurred under the condition of TSR = 4, α = 5%, ks/ds = 1 × 10−2, and TI = 8%.

Author(s):  
Jim Shih-Jiun Chen ◽  
Zhi Chen ◽  
Saroj Biswas ◽  
Jiun-Jih Miau ◽  
Cheng-Han Hsieh

Vertical axis wind turbines (VAWT) have been valued in recent years for their low manufacturing cost, structural simplicity and convenience of applications in urban settings. Despite their advantages, VAWTs have several drawbacks including low power coefficient, poor self-starting ability, negative torque and the associated cyclic stress at certain azimuth angles. Using pitch control ideas, our research is aimed at solving the above problems. In this study, a small-scale Giromill VAWT using three NACA-0015 airfoils with a cord length of 0.09 m and a wind turbine radius of 0.6 m is investigated. During each rotation, the angle of attack depends on the wind velocity, angular velocity and current azimuth angle for each turbine blade. Negative torques at certain angles are attributed to the inherent unsteady aerodynamic behavior at high angles of attack. Without optimal pitch control, the Double-Multiple Streamtube (DMS) model predicts negative torques at certain azimuth angles and very low power coefficients for tip speed ratios below 2.5. The unfavorable negative torques are eliminated using an optimal pitch control strategy, which maximizes the tangential force coefficients and thus the torque coefficients by iterations of all possible relative angles of attack for various tip speed ratios. As a result, the power coefficient is significantly improved especially at low tip speed ratios in the range of zero to three (λ = 0 – 3). Blade pitch control can also solve the self-starting problem and reduce the vibration of vertical axis wind turbines.


2018 ◽  
Vol 10 (9) ◽  
pp. 168781401879954
Author(s):  
Soo-Yong Cho ◽  
Sang-Kyu Choi ◽  
Jin-Gyun Kim ◽  
Chong-Hyun Cho

In order to augment the performance of vertical axis wind turbines, wind power towers have been used because they increase the frontal area. Typically, the wind power tower is installed as a circular column around a vertical axis wind turbine because the vertical axis wind turbine should be operated in an omnidirectional wind. As a result, the performance of the vertical axis wind turbine depends on the design parameters of the wind power tower. An experimental study was conducted in a wind tunnel to investigate the optimal design parameters of the wind power tower. Three different sizes of guide walls were applied to test with various wind power tower design parameters. The tested vertical axis wind turbine consisted of three blades of the NACA0018 profile and its solidity was 0.5. In order to simulate the operation in omnidirectional winds, the wind power tower was fabricated to be rotated. The performance of the vertical axis wind turbine was severely varied depending on the azimuthal location of the wind power tower. Comparison of the performance of the vertical axis wind turbine was performed based on the power coefficient obtained by averaging for the one periodic azimuth angle. The optimal design parameters were estimated using the results obtained under equal experimental conditions. When the non-dimensional inner gap was 0.3, the performance of the vertical axis wind turbine was better than any other gaps.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Abhijeet M. Malge ◽  
Prashant Maruti Pawar

Purpose Three different configurations of vertical axis wind turbines (VAWT) were fabricated by changing the storey height and their orientations. The purpose of this study is to find the effect of storey height and orientation on the performance of wind turbines. The multistory VAWT has three storeys. The first configuration had increased middle storey height, with 0–90-0 orientation of blades. Wherein the second turbine had equal storey heights. The third configuration had increased middle storey height with 0–120-240 orientation of blades. The blades were tested numerically and experimentally. Design/methodology/approach In this research work, prototypes of innovative multistory VAWT were built with different configurations and orientations. Three configurations of three-storey VAWT were fabricated by varying the height of storey of turbines. The orientations were made by keeping the storeys orthogonal to each other. Multistory VAWT was tested numerically and experimentally. ANSYS Fluent was used for computational fluid dynamic analysis of VAWT. K-epsilon model was used for numerical analysis of wind turbine. Experimentation was carried out in a wind tunnel for different tip speed ratios (TSR). Findings The three configurations of innovative multistory VAWT were tested numerically and experimentally for different TSR. It has been found that the VAWT with equal storey height had a better performance as compared to the other two configurations with increased middle storey height. The power coefficient of equal storey height VAWT was about 22%, wherein the power coefficient of turbines with reduced upper and lower storey height was between 5%–8% Research limitations/implications The research work of multi-storey VAWT is very novel and original. The findings of the research will contribute to the existing work done in the field of VAWT. This will help other researchers to have insight into the development of multistory VAWT. The effect of storey height and configuration of multi-storey VAWT is studied numerically and experimentally, which concludes that the performance of equal storey is superior as compared to other configurations. Practical implications The multi-storey concept of VAWT was developed to counter the problem of wind direction. The blades of each storey were arranged orthogonal to each other. This helped to harness wind power irrespective of the direction of the wind. This will make the VAWT more sustainable and financially viable for domestic use. Social implications The turbines are specially designed for remotely located housed in rural areas where the power grid is not yet reached. Users can install the turbine on their rooftop and harness wind power of 100 W capacity. This will help them to make their life easy. Originality/value This research work is very original and first of a kind. The multistory concept of the wind turbine was checked for the effect of storey height and orientations of blades on its performance. Different configurations and orientations of the vertical axis were designed and developed for the first time.


Author(s):  
Mosfequr Rahman ◽  
Khandakar N. Morshed ◽  
Jeffery Lewis ◽  
Mark Fuller

With the growing demand of energy worldwide, conventional energy is becoming more and more scarce and expensive. The United States is already facing an energy crunch as the fuel price soars. Therefore, there is an obvious need for alternative sources of energy—perhaps more than ever. Wind is among the most popular and fastest-growing forms of electricity generation in the world, which is pollution free and available almost at any time of the day, especially in the coastal regions. The main attraction of the vertical-axis wind turbine is its manufacturing simplicity compared to that of the horizontal-axis wind turbine. Among all different vertical axis wind turbines, Savonius wind turbine is the simplest one. Operation of the Savonius wind turbine is based on the difference of the drag force on its semi-spherical blades, depending on whether the wind is striking the convex or the concave part of the blades. The advantage of this type of wind turbine is its good self-starting and wind directional independence characteristic. It, however, has a relatively lower efficiency in comparison with the lift type vertical-axis wind turbines. Due to its simple design and low construction cost, Savonius rotors are primarily used for water pumping and wind power on a small scale. The main objective of this ongoing research work is to improve the aerodynamic performance of vertical axis Savonius wind turbine. Wind tunnel investigation has been performed on aerodynamic characteristics, such as drag coefficients, and static torque coefficient of three-bladed Savonius rotor model. Also the computational fluid dynamics (CFD) simulation has been performed using FLUENT software to analyze the static rotor aerodynamics such as drag coefficients and torque coefficient, and these results are compared with the corresponding experimental results for verification.


2019 ◽  
Vol 44 (2) ◽  
pp. 115-124 ◽  
Author(s):  
Gareth Erfort ◽  
Theodor W. von Backström ◽  
Gerhard Venter

Vertical axis wind turbines have a place in the small scale renewable energy market. They are not currently implemented on a commercial scale but have found a niche space in urban areas. Here, the turbulent wind conditions and limited space are more easily tapped into with a vertical axis wind turbine. However, the challenges facing these types of turbines have hampered deployment. One of these issues is the fluctuating torque experienced during operation, which can lead to over-designed power trains. Genetic- and gradient-based optimization is applied to an analytical model of a vertical axis wind turbine, in order to reduce the torque fluctuation while attempting to maintain a high power coefficient. The reduction in torque ripple is achieved through a sinusoidal pitching motion of the blades. The torque ripple can be reduced by 10% with a similar reduction in power coefficient.


2007 ◽  
Vol 31 (5) ◽  
pp. 363-368 ◽  
Author(s):  
A. Biswas ◽  
R. Gupta ◽  
K.K. Sharma

Savonius vertical axis wind turbines (VAWT) have advantages over horizontal axis wind turbines (HAWT), such as simple construction, acceptance of wind from any direction without orientation, self-starting, inexpensive etc. These advantages make it a viable proposition for small-scale applications in developing countries. In spite of the above advantages, VAWT are not gaining popularity mainly because of their poor efficiency. Hence, a three-bucket Savonius model rotor, having 8 cm bucket diameter and 20 cm height, was designed, fabricated, and tested in a sub-sonic wind tunnel. Provisions for variations of ‘blade’ overlap were included. Experiments were conducted for overlap conditions in the range of 16% to 35%. From the experimental investigations, power-coefficients (Cp) were calculated with and without blockage correction factors for tunnel interference. In both analyses, the power-coefficient increased if there was overlap, with an optimum value at 20% overlap of 47% without blockage correction, and 38% with blockage correction.


2021 ◽  
Vol 11 (17) ◽  
pp. 8011
Author(s):  
Sajad Maleki Dastjerdi ◽  
Kobra Gharali ◽  
Armughan Al-Haq ◽  
Jatin Nathwani

Two novel four-blade H-darrieus vertical axis wind turbines (VAWTs) have been proposed for enhancing self-start capability and power production. The two different airfoil types for the turbines are assessed: a cambered S815 airfoil and a symmetric NACA0018 airfoil. For the first novel wind turbine configuration, the Non-Similar Airfoils 1 (NSA-1), two NACA0018 airfoils, and two S815 airfoils are opposite to each other. For the second novel configuration (NSA-2), each of the S815 airfoils is opposite to one NACA0018 airfoil. Using computational fluid dynamics (CFD) simulations, static and dynamic conditions are evaluated to establish self-starting ability and the power coefficient, respectively. Dynamic stall investigation of each blade of the turbines shows that NACA0018 under dynamic stall impacts the turbine’s performance and the onset of dynamic stall decreases the power coefficient of the turbine significantly. The results show that NSA-2 followed by NSA-1 has good potential to improve the self-starting ability (13.3%) compared to the turbine with symmetric airfoils called HT-NACA0018. In terms of self-starting ability, NSA-2 not only can perform in about 66.67% of 360° similar to the wind turbine with non-symmetric airfoils (named HT-S815) but the power coefficient of NSA-2 at the design tip speed ratio of 2.5 is also 4.5 times more than the power coefficient of HT-S815; the power coefficient difference between HT-NACA0018 and HT-S815 (=0.231) is decreased significantly when HT-S815 is replaced by NSA-2 (=0.076). These novel wind turbines are also simple.


2019 ◽  
pp. 0309524X1987402 ◽  
Author(s):  
Gareth Erfort ◽  
Theodor W von Backström ◽  
Gerhard Venter

Vertical-axis wind turbines have been confined to small-scale generation in urban environments where their omnidirectional capability offers them an advantage over the more ubiquitous horizontal-axis wind turbine. With a drive towards renewable energy, more opportunities exist for the implementation of wind turbines in a multitude of environments. Based on its inherent operational drawbacks, the vertical-axis wind turbine has not undergone extensive investigation. Recently, there has been a resurgence of interest in the technology. This article addresses the torque ripple, a variation in torque produced by the turbine, present during operation. The variation in torque generated by a vertical-axis wind turbine increases the likelihood of failure due to fatigue. Current treatment is symptomatic and addresses the result of the torque fluctuation and not the cause. A novel blade design, capable of altering the lift and drag response through shape alteration, is presented as a solution. The blade design and operation is achieved through genetic algorithm optimization and computational fluid dynamic simulations. Comparisons with previous work show the novel blade presented here surpasses the reduction seen with pitching solutions. A 25% reduction in torque ripple was demonstrated for a 17% reduction in performance coefficient using the surface distortion approach. This surpasses the foil pitching approach which achieved a 15% torque ripple reduction for the same loss in performance coefficient.


2021 ◽  
pp. 0309524X2110618
Author(s):  
Syed Abdur Rahman Tahir ◽  
Muhammad Shakeel Virk

Vertical Axis Wind Turbine (VAWT) can be a promising solution for electricity production in remote ice prone territories of high north, where good wind resources are available, but icing is a challenge that can affect its optimum operation. A lot of research has been made to study the icing effects on the conventional horizontal axis wind turbines, but the literature about vertical axis wind turbines operating in icing conditions is still scarce, despite the importance of this topic. This paper presents a review study about existing knowledge of VAWT operation in icing condition. Focus has been made in better understanding of ice accretion physics along VAWT blades and methods to detect and mitigate icing effects.


Sign in / Sign up

Export Citation Format

Share Document