scholarly journals Investigation and Evaluation of Winter Indoor Air Quality of Primary Schools in Severe Cold Weather Areas of China

Energies ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1602 ◽  
Author(s):  
Fusheng Ma ◽  
Changhong Zhan ◽  
Xiaoyang Xu

The indoor air quality (IAQ) in classrooms has attracted more and more attention. Unfortunately, there is limited information relating to IAQ in the primary schools in severe cold weather areas of China. In this study, a field investigation on the IAQ of a primary school of Shenyang in northeast China was carried out by physical measurements and questionnaire surveys. The carbon dioxide (CO2) concentration in selected classrooms was continuously measured for a week, and the corresponding ventilation rate was calculated. Meanwhile, the perceptions of the IAQ, the purpose and the comfort degree of window opening have also been recorded from 106 pupils, aged 9–12. The results indicate the ventilation rate is considerably inadequate in about 99% of the class time due to the low frequency of window opening. The average daily CO2 concentration in these classrooms is 1510–3863 ppm, which is far higher than the recommended value of 1000 ppm. Most pupils understand that the purpose of opening windows in winter is to improve air quality. However, there are big differences between the measurement results and subjective judgments of indoor air quality. Contrary to the high measured CO2 concentration, around 70% pupils consider the air fresh, and only 3.7% pupils are dissatisfied and even very dissatisfied with IAQ in their classroom. It is necessary to change the existing manual window opening mode, because the pupils’ subjective judgment affects the window opening behavior.

2021 ◽  
Vol 13 (8) ◽  
pp. 4139
Author(s):  
Muriel Diaz ◽  
Mario Cools ◽  
Maureen Trebilcock ◽  
Beatriz Piderit-Moreno ◽  
Shady Attia

Between the ages of 6 and 18, children spend between 30 and 42 h a week at school, mostly indoors, where indoor environmental quality is usually deficient and does not favor learning. The difficulty of delivering indoor air quality (IAQ) in learning facilities is related to high occupancy rates and low interaction levels with windows. In non-industrialized countries, as in the cases presented, most classrooms have no mechanical ventilation, due to energy poverty and lack of normative requirements. This fact heavily impacts the indoor air quality and students’ learning outcomes. The aim of the paper is to identify the factors that determine acceptable CO2 concentrations. Therefore, it studies air quality in free-running and naturally ventilated primary schools in Chile, aiming to identify the impact of contextual, occupant, and building design factors, using CO2 concentration as a proxy for IAQ. The monitoring of CO2, temperature, and humidity revealed that indoor air CO2 concentration is above 1400 ppm most of the time, with peaks of 5000 ppm during the day, especially in winter. The statistical analysis indicates that CO2 is dependent on climate, seasonality, and indoor temperature, while it is independent of outside temperature in heated classrooms. The odds of having acceptable concentrations of CO2 are bigger when indoor temperatures are high, and there is a need to ventilate for cooling.


Author(s):  
Maria do Carmo Freitas ◽  
Nuno Canha ◽  
Maria Martinho ◽  
Marina Almeida-Silva ◽  
Susana Marta ◽  
...  

Author(s):  
Marek Telejko ◽  
Ewa Zender-Swiercz

Most primary school buildings in Poland rely on natural ventilation. This fact is attributed to the age of these buildings constructed more than dozen or even several tens of years ago. Few of them were fitted with a mechanical ventilation system allowing for the adjustment of microclimate parameters. The national requirements for gravity ventilation provide general guidelines, specifying strict description only for the airtightness of windows and doors and the minimum airflow to be supplied to the rooms. The minimum airflow supplied is independent of the number of occupants and purpose of the room. Low indoor air quality (IAQ) can impact occupants’ health and lead to poor productivity or low academic performance. Therefore the provision of good IAQ in classrooms and laboratories is very important. This paper presents the results of the investigation devoted to the quality of indoor air in classrooms of selected Polish primary school. Six primary school in a town with a population of 200 000 inhabitants were involved in the investigations. The participating school buildings were built between 1976 and 1994 and had gravity ventilation systems. The variability of basic IAQ parameters, i.e., temperature, relative humidity and carbon dioxide level, was analysed and the assessment of the classrooms in terms of microbiological purity was performed. The outcomes confirmed the low quality of the indoor air in these buildings. The maximum value of CO2 concentration amounted to more than 4000 ppm. Certain modifications aimed at improving IAQ were proposed during the investigations. Two solutions were implemented. The results of this study indicate that the proposed solution offers the potential to improve IAQ within classrooms.


Buildings ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 124 ◽  
Author(s):  
Claire Tam ◽  
Yuqing Zhao ◽  
Zaiyi Liao ◽  
Lian Zhao

Indoor air quality and thermal conditions are important considerations when designing indoor spaces to ensure occupant health, satisfaction, and productivity. Carbon dioxide (CO2) concentration and indoor air temperature are two measurable parameters to assess air quality and thermal conditions within a space. Occupants are progressively affected by the indoor environment as the time spent indoors prolongs. Specifically, there is an interest in carrying out investigations on the indoor environment through surveying existing Heating, Ventilation, Air Conditioning (HVAC) system operations in classrooms. Indoor air temperature and CO2 concentration in multiple lecture halls in Toronto, Canada were monitored; observations consistently show high indoor air temperature (overheating) and high CO2 concentration. One classroom is chosen as a representative case study for this paper. The results verify a strong correlation between the number of occupants and the increase in air temperature and CO2 concentration. Building Energy Simulation (BES) is used to investigate the causes of discomfort in the classroom, and to identify methods for regulating the temperature and CO2 concentration. This paper proposes retro-commissioning strategies that could be implemented in institutional buildings; specifically, the increase of outdoor airflow rate and the addition of occupancy-based pre-active HVAC system control. The proposed retrofit cases reduce the measured overheating in the classrooms by 2-3 °C (indoor temperature should be below 23 °C) and maintain CO2 concentration under 900 ppm (the CO2 threshold is 1000 ppm), showing promising improvements to a classroom’s thermal condition and indoor air quality.


2020 ◽  
pp. 1420326X2092474
Author(s):  
Tingxuan Deng ◽  
Xiong Shen ◽  
Xiaojie Cheng ◽  
Junjie Liu

Indoor air quality (IAQ) is a key factor that could affect the indoor environment and people's health. In this study, we report a comprehensive study on IAQ in 30 dwellings in the temperate zone in China. Thirty naturally ventilated dwellings were selected in the urban area of Kunming, which is the largest city in temperate zone in China. In four seasons, short-term measurement of formaldehyde and benzene, toluene, xylenes-volatile organic compounds and air infiltration rate were conducted in these dwellings. A long-term 1-year monitoring of temperature, relative humidity, fine particulate matter (PM2.5), carbon dioxide (CO2), window-opening behaviour and night-time air change rate (ACR) were conducted in 13 of these dwellings by remote sensors. Short-term measurements showed the mean formaldehyde concentration in summer (100.76 μg/m3), benzene concentration in winter (8.46 µg/m3), PM2.5 concentration (80.4 µg/m3) in spring of 2017 exceeded the Chinese standard, the US Office of Environmental Health Hazard Assessment value and the World Health Organization guidelines. The night-time ACR was the highest in summer (2.1 h−1) and the lowest in winter (1.6 h−1) in bedrooms of 13 long-term monitored dwellings due to seasonal time variation in window opening in bedrooms, which was mainly driven by CO2 concentration, indoor temperature and outdoor PM10 concentration.


2014 ◽  
Vol 40 (3) ◽  
pp. 259-268 ◽  
Author(s):  
Ana Maria da Conceição Ferreira ◽  
Massano Cardoso

Objective: To determine whether indoor air quality in schools is associated with the prevalence of allergic and respiratory diseases in children. Methods: We evaluated 1,019 students at 51 elementary schools in the city of Coimbra, Portugal. We applied a questionnaire that included questions regarding the demographic, social, and behavioral characteristics of students, as well as the presence of smoking in the family. We also evaluated the indoor air quality in the schools. Results: In the indoor air of the schools evaluated, we identified mean concentrations of carbon dioxide (CO2) above the maximum reference value, especially during the fall and winter. The CO2 concentration was sometimes as high as 1,942 ppm, implying a considerable health risk for the children. The most prevalent symptoms and respiratory diseases identified in the children were sneezing, rales, wheezing, rhinitis, and asthma. Other signs and symptoms, such as poor concentration, cough, headache, and irritation of mucous membranes, were identified. Lack of concentration was associated with CO2 concentrations above the maximum recommended level in indoor air (p = 0.002). There were no other significant associations. Conclusions: Most of the schools evaluated presented with reasonable air quality and thermal comfort. However, the concentrations of various pollutants, especially CO2, suggest the need for corrective interventions, such as reducing air pollutant sources and improving ventilation. There was a statistically significant association between lack of concentration in the children and exposure to high levels of CO2. The overall low level of pollution in the city of Coimbra might explain the lack of other significant associations.


Proceedings ◽  
2018 ◽  
Vol 2 (20) ◽  
pp. 1309 ◽  
Author(s):  
Antonio Rodero ◽  
Dorota Anna Krawczyk

Carbon dioxide concentration is an important parameter to know Indoor Air Quality of a building. One of the most important sources of CO2 in poor ventilated building is human activity. This work presents a method for experimental determination of human CO2 generation rate based on measuring of time evolution of indoor CO2 concentration. The method is applied to 5 rooms of an educational building from Bialystok (Poland). Similar carbon dioxide gains were obtained in all rooms, around 0.0046 L/s, which correspond to theoretical CO2 generation rates of a sedentary activity for persons, males and females, between 21–30 years old, characteristics of occupants of analyzed rooms.


Author(s):  
Cesira Pasquarella ◽  
Carla Balocco ◽  
Maria Eugenia Colucci ◽  
Elisa Saccani ◽  
Samuel Paroni ◽  
...  

Surgical staff behavior in operating theatres is one of the factors associated with indoor air quality and surgical site infection risk. The aim of this study was to apply an approach including microbiological, particle, and microclimate parameters during two simulated surgical hip arthroplasties to evaluate the influence of staff behavior on indoor air quality. During the first hip arthroplasty, the surgical team behaved correctly, but in the second operation, behavioral recommendations were not respected. Microbiological contamination was evaluated by active and passive methods. The air velocity, humidity, temperature, and CO2 concentration were also monitored. The highest levels of microbial and particle contamination, as well as the highest variation in the microclimate parameter, were recorded during the surgical operation where the surgical team behaved “incorrectly”. Turbulent air flow ventilation systems appeared more efficient than in the past and very low air microbial contamination was reached when behavior was correct. Therefore, adherence to behavioral recommendations in operating theatres is essential to not undermine the effectiveness of the heating, ventilation, and air conditioning systems and employed resources.


Atmosphere ◽  
2020 ◽  
Vol 11 (3) ◽  
pp. 271 ◽  
Author(s):  
Kanittha Pamonpol ◽  
Thanita Areerob ◽  
Kritana Prueksakorn

Optimum thermal comfort and good indoor air quality (IAQ) is important for occupants. In tropical region offices, an air conditioner is indispensable due to extreme high temperatures. However, the poor ventilation causes health issues. Therefore, the purpose of this study was to propose an improving IAQ method with low energy consumption. Temperature, relative humidity, and CO2 and CO concentration were monitored in a poorly ventilated office for one year to observe seasonal variation. The results showed that the maximum CO2 concentration was above the recommended level for comfort. Simple ventilated practices and placing a number of Sansevieria trifasciata (S. trifasciata) plants were applied to improve the IAQ with the focus on decreasing CO2 concentration as well as achieving energy saving. Reductions of 19.9%, 22.5%, and 58.2% of the CO2 concentration were achieved by ventilation through the door during lunchtime, morning, and full working period, respectively. Placing S. trifasciata in the office could reduce the CO2 concentration by 10.47%–19.29%. A computer simulation was created to observe the efficiency of simple practices to find the optimum conditions. An electricity cost saving of 24.3% was projected for the most feasible option with a consequent reduction in global warming potential, which also resulted in improved IAQ.