scholarly journals Energy and Economic Assessment of Energy Efficiency Options for Energy Districts: Case Studies in Italy and Egypt

Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1012
Author(s):  
Francesco Calise ◽  
Francesco L. Cappiello ◽  
Maria Vicidomini ◽  
Jian Song ◽  
Antonio M. Pantaleo ◽  
...  

In this research, a technoeconomic comparison of energy efficiency options for energy districts located in different climatic areas (Naples, Italy and Fayoum, Egypt) is presented. A dynamic simulation model based on TRNSYS is developed to evaluate the different energy efficiency options, which includes different buildings of conceived districts. The TRNSYS model is integrated with the plug-in Google SketchUp TRNSYS3d to estimate the thermal load of the buildings and the temporal variation. The model considers the unsteady state energy balance and includes all the features of the building’s envelope. For the considered climatic zones and for the different energy efficiency measures, primary energy savings, pay back periods and reduced CO2 emissions are evaluated. The proposed energy efficiency options include a district heating system for hot water supply, air-to-air conventional heat pumps for both cooling and space heating of the buildings and the integration of photovoltaic and solar thermal systems. The energy actions are compared to baseline scenarios, where the hot water and space heating demand is satisfied by conventional natural gas boilers, the cooling demand is met by conventional air-to-air vapor compression heat pumps and the electric energy demand is satisfied by the power grid. The simulation results provide valuable guidance for selecting the optimal designs and system configurations, as well as suggest guidelines to policymakers to define decarbonization targets in different scenarios. The scenario of Fayoum offers a savings of 67% in primary energy, but the associated payback period extends to 23 years due to the lower cost of energy in comparison to Naples.

Author(s):  
Praveen Cheekatamarla ◽  
Vishaldeep Sharma ◽  
Bo Shen

Abstract Economic and population growth is leading to increased energy demand across all sectors – buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Supporting the current and future building thermal energy needs to offset the total electric demand while lowering the carbon footprint and enhancing the grid flexibility is presented in this study. Performance assessment of heat pumps, renewable energy, non-fossil fuel-based cogeneration systems, and their hybrid configurations was conducted. The impact of design configuration, coefficient of performance (COP), electric grid's primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail.


2020 ◽  
Vol 160 ◽  
pp. 01004 ◽  
Author(s):  
Stanislav Chicherin ◽  
Lyazzat Junussova ◽  
Timur Junussov

Proper adjustment of domestic hot water (DHW) load structure can balance energy demand with the supply. Inefficiency in primary energy use prompted Omsk DH company to be a strong proponent of a flow controller at each substation. Here the return temperature is fixed to the lowest possible value and the supply temperature is solved. Thirty-five design scenarios are defined for each load deviation index with equally distributed outdoor temperature ranging from +8 for the start of a heating season towards extreme load at temperature of -26°C. All the calculation results are listed. If a flow controller is installed, the customers might find it suitable to switch to this type of DHW supply. Considering an option with direct hot water extraction as usual and a flow controller installed, the result indicates that the annual heat consumption will be lower once network temperatures during the fall or spring months are higher. The heat load profiles obtained here may be used as input for a simulation of a DH substation, including a heat pump and a tank for thermal energy storage. This design approach offers a quantitative way of sizing temperature levels in each DH system according to the listed methodology and the designer's preference.


2018 ◽  
Vol 70 ◽  
pp. 01001
Author(s):  
Jacek Biskupski

This paper gives a thorough description of the two different scenarios of retrofit of an existing detached country house (with high primary energy demand) to a net zero energy building (nZEB) or near zero energy (nearZEB) by using energy form on-site RES. Using a designed piece of modelling software author pointed out two possible solutions. First one, based on a bio boiler and small on-site PV generator (on-grid) and the other based on large PV generator and three heat pumps. A 24 months test was performed in order to find out the output of both scenarios. In first period, the bio boiler delivered energy for space heating and DHW, while energy from PV was used to cover all electricity needs of the household during the 12 months testing period. In the later, the energy received from 10 kWp PV of was partly used to cover the current needs of the entire household (switchable on/off-grid system), and surplus was stored in the national electricity grid and regained later in the winter for the space heating (by a GSHP) and ventilation (ASHP) and DHW (dedicated ASHP). In both cases the system proofed the possibility to achieve the nZEB (nearZEB in first scenario) state of the household, as all (in the first near all) energy needs were covered by renewable energy produced on-site.


Author(s):  
Benkechkache Imane

Energy is one of the common determinant factors related to social, environmental and economic problems, which can also contribute to their solution. Among sectors where studies could be done to reduce energy demand, is building. This latter is the largest primary energy consumer and responsible for more than 40% of total CO2 emissions. Therefore, improving energy efficiency in buildings represents an economic and ecological challenge. The built environment quality, with good insulation and high-performance building materials, constitutes the first step towards this aim. Yet, this is not enough to make buildings low energy consumption. But then again, a starting point for which, it is necessary to manage how it should be occupied and exploited. Improving energy efficiency of buildings involves several steps through which, coherent actions, will enable energy savings acting on different human and material parameters. The conceptual approach for improving energy efficiency is identical for residential and tertiary sectors. However, in practice this is different due to divergences related to: technical aspects; used tools; operating and maintenance costs and return time of investment. The purpose of this research is to investigate an example of Energy Enhancement housing in Tafilelt ksar in the M’zab valley in Algeria (an example of ecologic planning with modern habitat perfectly adapted to environment), with the objective of creating adaptable housing according to changing needs of future generations.


2021 ◽  
Vol 312 ◽  
pp. 06001
Author(s):  
Giorgio Villa ◽  
Rossano Scoccia ◽  
Tommaso Toppi ◽  
Marcello Aprile

The aim of this paper is to compare energy consumptions, CO2 emissions, and operative costs of condensing boilers, electric vapour compression heat pumps and gas driven absorption heat pumps to provide space heating and domestic hot water. The analysis is performed for 140 m2 single-family houses in five different Italian cities whose envelope features depend on the location. For each location, two different envelope conditions are considered. The first one is a non-insulated building, while the second one is the same building, but an external thermal insulation is added on vertical walls and roof. To avoid internal renovation, radiators are maintained as emission system. Combined dynamic simulations are performed to appreciate building and system interactions. A 6 second time step is set to evaluate properly interactions and the DHW profile demand. In addition, the GHP dynamic model is a grey box model experimentally validated. The results show that electric vapour compression heat pumps reach the highest non-renewable primary energy savings (>32%) compared to condensing boilers, but their operative costs are higher due to the higher specific cost of electricity in Italy. Gas driven absorption heat pumps achieve a lower consumption reduction than electric heat pumps (>22%), but they have also the minimum operative cost among the three technologies.


2016 ◽  
Vol 19 ◽  
pp. 50-58 ◽  
Author(s):  
Michael Beck ◽  
Karsten Müller ◽  
Wolfgang Arlt

A promising approach for increasing the energy efficiency of domestic households and buildings is to optimize the whole energy system by coupling of different heat sources and sinks. This procedure, known as heat integration, is state of the art in the industrial sector and is now applied to the residential sector. In this work several options for increasing the energy efficiency and for recovering waste heat are discussed. In order to reduce the primary energy demand different waste heat sources like domestic hot water or household appliances (refrigerators or freezers) were evaluated. The first step is the development of an advanced form of the stationary Pinch Analysis. This was subsequently applied to determine the thermodynamically possible energy saving for a single family home.


2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3350
Author(s):  
Theofanis Benakopoulos ◽  
William Vergo ◽  
Michele Tunzi ◽  
Robbe Salenbien ◽  
Svend Svendsen

The operation of typical domestic hot water (DHW) systems with a storage tank and circulation loop, according to the regulations for hygiene and comfort, results in a significant heat demand at high operating temperatures that leads to high return temperatures to the district heating system. This article presents the potential for the low-temperature operation of new DHW solutions based on energy balance calculations and some tests in real buildings. The main results are three recommended solutions depending on combinations of the following three criteria: district heating supply temperature, relative circulation heat loss due to the use of hot water, and the existence of a low-temperature space heating system. The first solution, based on a heating power limitation in DHW tanks, with a safety functionality, may secure the required DHW temperature at all times, resulting in the limited heating power of the tank, extended reheating periods, and a DH return temperature of below 30 °C. The second solution, based on the redirection of the return flow from the DHW system to the low-temperature space heating system, can cool the return temperature to the level of the space heating system return temperature below 35 °C. The third solution, based on the use of a micro-booster heat pump system, can deliver circulation heat loss and result in a low return temperature below 35 °C. These solutions can help in the transition to low-temperature district heating.


2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC


2006 ◽  
Vol 129 (2) ◽  
pp. 226-234
Author(s):  
Robert Hendron ◽  
Mark Eastment ◽  
Ed Hancock ◽  
Greg Barker ◽  
Paul Reeves

Building America (BA) partner McStain Neighborhoods built the Discovery House in Loveland, CO, with an extensive package of energy-efficient features, including a high-performance envelope, efficient mechanical systems, a solar water heater integrated with the space-heating system, a heat-recovery ventilator (HRV), and ENERGY STAR appliances. The National Renewable Energy Laboratory (NREL) and Building Science Consortium conducted short-term field-testing and building energy simulations to evaluate the performance of the house. These evaluations are utilized by BA to improve future prototype designs and to identify critical research needs. The Discovery House building envelope and ducts were very tight under normal operating conditions. The HRV provided fresh air at a rate of about 35L∕s(75cfm), consistent with the recommendations of ASHRAE Standard 62.2. The solar hot water system is expected to meet the bulk of the domestic hot water (DHW) load (>83%), but only about 12% of the space-heating load. DOE-2.2 simulations predict whole-house source energy savings of 54% compared to the BA Benchmark (Hendron, R., 2005 NREL Report No. 37529, NREL, Golden, CO). The largest contributors to energy savings beyond McStain’s standard practice are the solar water heater, HRV, improved air distribution, high-efficiency boiler, and compact fluorescent lighting package.


Sign in / Sign up

Export Citation Format

Share Document