scholarly journals Gas Engine-Driven Heat Pumps for Small-Scale Applications: State-of-the-Art and Future Perspectives

Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4845
Author(s):  
Carlo Roselli ◽  
Elisa Marrasso ◽  
Maurizio Sasso

Gas engine-driven heat pumps are an interesting option to satisfy space heating and cooling demands aiming at energy saving, environmental impact and operating costs’ reduction. This work presents (i) a comprehensive review updated on gas engine-driven heat pumps research activities, (ii) the investigation of the central role of this technology in the air conditioning sector and (iii) the future perspectives regarding gas engine heat pumps’ diffusion in the context of the energy sector decarbonisation. The outcomes highlight that gas engine heat pumps could have better environmental performance compared to electric heat pumps both in heating and cooling operations. Moreover, they could play a pivotal role in the fight against climate change and energy security since they can guarantee an energy mix differentiation moving from electricity to natural gas and renewable gases’ usage. Indeed, by 2030, a lower-carbon gas grid could be supported by renewable gases. A further investigation has concerned diffusion of gas heat pumps activated from biofuels produced by local biomass in an energy community scenario based on a low-temperature energy district network. A novel biomass-based GEHP interacting with a low-temperature district heating network is proposed here. This system could save more than 30% of primary energy compared to biomass-fuelled boilers.

2019 ◽  
Vol 9 (15) ◽  
pp. 3194 ◽  
Author(s):  
Urbanucci ◽  
Testi ◽  
Bruno

District heating and cooling networks based on trigeneration systems and renewable energy technologies are widely acknowledged as an energy efficient and environmentally benign solution. These energy systems generally include back-up units, namely fossil-fuel boilers and electric chillers, to enhance system flexibility and cover peak energy demand. On the other hand, 4th generation district heating networks are characterized by low-temperature water distribution to improve energy and exergy efficiencies. Moreover, reversible heat pumps are a versatile technology, capable of providing both heating and cooling, alternately. In this paper, the integration of reversible heat pumps as single back-up units in hybrid renewable trigeneration systems serving low-energy micro-district heating and cooling networks is investigated. A detailed modeling of the system is provided, considering part-load and ambient condition effects on the performance of the units. Size and annual operation of the proposed system are optimized in a case study, namely a large office building located in Pisa (Italy), by means of a genetic algorithm-based procedure. A comparison with the conventional trigeneration system is performed in terms of economic and environmental perspectives. Results show that the integration of reversible heat pumps is an economically viable solution capable of reducing by 7% the equivalent annual cost, increasing the installed power of renewables up to 23%, and lowering by 11% carbon dioxide emissions, compared to the energy system with conventional back-up units.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 954 ◽  
Author(s):  
Hanne Kauko ◽  
Daniel Rohde ◽  
Armin Hafner

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.


Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2347
Author(s):  
Elżbieta Hałaj ◽  
Jarosław Kotyza ◽  
Marek Hajto ◽  
Grzegorz Pełka ◽  
Wojciech Luboń ◽  
...  

Krakow has an extensive district heating network, which is approximately 900 km long. It is the second largest city in terms of the number of inhabitants in Poland, resulting in a high demand for energy—for both heating and cooling. The district heating of the city is based on coal. The paper presents the conception of using the available renewable sources to integrate them into the city’s heating system, increasing the flexibility of the system and its decentralization. An innovative solution of the use of hybrid, modular heat pumps with power dependent on the needs of customers in a given location and combining them with geothermal waters and photovoltaics is presented. The potential of deep geothermal waters is based on two reservoirs built of carbonate rocks, namely Devonian and Upper Jurassic, which mainly consist of dolomite and limestone. The theoretical potential of water intake equal to the nominal heating capacity of a geothermal installation is estimated at 3.3 and 2.0 MW, respectively. Shallow geothermal energy potential varies within the city, reflecting the complex geological structure of the city. Apart from typical borehole heat exchangers (BHEs), the shallower water levels may represent a significant potential source for both heating and cooling by means of water heat pumps. For the heating network, it has been proposed to use modular heat pumps with hybrid sources, which will allow for the flexible development of the network in places previously unavailable or unprofitable. In the case of balancing production and demand, a photovoltaic installation can be an effective and sufficient source of electricity that will cover the annual electricity demand generated by the heat pump installation, when it is used for both heating and cooling. The alternating demand of facilities for heating and cooling energy, caused by changes in the seasons, suggests potential for using seasonal cold and heat storage.


Author(s):  
Mohammad Omar Temori ◽  
František Vranay

In this work, a mini review of heat pumps is presented. The work is intended to introduce a technology that can be used to income energy from the natural environment and thus reduce electricity consumption for heating and cooling. A heat pump is a mechanical device that transfers heat from one environmental compartment to another, typically against a temperature gradient (i.e. from cool to hot). In order to do this, an energy input is required: this may be mechanical, electrical or thermal energy. In most modern heat pumps, electrical energy powers a compressor, which drives a compression - expansion cycle of refrigerant fluid between two heat exchanges: a cold evaporator and a warm condenser. The efficiency or coefficient of performance (COP), of a heat pump is defined as the thermal output divided by the primary energy (electricity) input. The COP decreases as the temperature difference between the cool heat source and the warm heat sink increases. An efficient ground source heat pump (GSHP) may achieve a COP of around 4. Heat pumps are ideal for exploiting low-temperature environmental heat sources: the air, surface waters or the ground. They can deliver significant environmental (CO2) and cost savings.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 810 ◽  
Author(s):  
Alessandro Guzzini ◽  
Marco Pellegrini ◽  
Edoardo Pelliconi ◽  
Cesare Saccani

Among the available solutions for building heating and cooling, district heating (DH) and district cooling (DC) systems are considered some of the best options since they can ensure a better control of pollutant emissions and greater efficiency than individual systems. Nevertheless, improvements are needed to increase their sustainability and reliability. The so-called “low temperature district heating” (LTDH) concept has been introduced in recent years in an attempt (i) to reduce the distribution heat losses through a temperature decrease in the DH network, (ii) to favor the integration with renewable energy sources, and (iii) to create the conditions required for the development of future smart energy systems. However, many concerns have been raised about its implementation in both existing and new systems. For this reason, this paper aims to identify the stakeholders’ ranking of the barriers against LTDH system development and implementation over the next few years. Aiming to this, a questionnaire was designed, including an analysis of current gaps and strengths, and then submitted to more than 50 Italian and international experts in the field of DH. An in-depth analysis of the received answers was performed, focusing in particular on the Italian experts’ answers. Comments and suggestions on how to promote the transition to the new LTDH approach are reported.


Energy ◽  
2014 ◽  
Vol 73 ◽  
pp. 399-415 ◽  
Author(s):  
Z.X. Jing ◽  
X.S. Jiang ◽  
Q.H. Wu ◽  
W.H. Tang ◽  
B. Hua

Sign in / Sign up

Export Citation Format

Share Document