scholarly journals Investigation of a Ventilation System for Energy Efficiency and Indoor Environmental Quality in a Renovated Historical Building: A Case Study

Author(s):  
Richard Nagy ◽  
Ľudmila Mečiarová ◽  
Silvia Vilčeková ◽  
Eva Krídlová Burdová ◽  
Danica Košičanová

This paper emphasizes the importance of environmental protection regarding the reduction of energy consumption while maintaining living standards. The aim of the research is to observe the effects of mechanical and natural ventilation on energy consumption and building operation as well as indoor environmental quality (IEQ). The results of indoor environmental quality testing show that the mean relative humidity (31%) is in the permissible range (30%–70%); the mean CO2 concentration (1050.5 ppm) is above the recommended value of 1000 ppm according to Pettenkofer; and the mean PM10 concentration (43.5 µg/m3) is under the limit value of 50 µg/m3. A very large positive correlation is found between relative humidity and concentration of CO2 as well as between the concentration of PM5 and the concentration of CO2. The most commonly occurring sick building syndrome (SBS) symptoms are found to be fatigue and the feeling of a heavy head.

Sensors ◽  
2021 ◽  
Vol 21 (21) ◽  
pp. 7223
Author(s):  
Antonio J. Aguilar ◽  
María L. de la Hoz-Torres ◽  
Mª Dolores Martínez-Aires ◽  
Diego P. Ruiz

Since students and teachers spend much of their time in educational buildings, it is critical to provide good levels of indoor environmental quality (IEQ). The current COVID-19 pandemic has shown that maintaining a good indoor air quality level is an effective measure to control the transmission of the SARS-CoV-2 virus. This study used sensors to monitor key IEQ factors and assess several natural ventilation scenarios in a classroom of the University of Granada. Subsequently, the IEQ factors (temperature, relative humidity, CO2 concentration, acoustic environment, and air velocity) were evaluated for the selected ventilation scenarios in the occupied classroom, and the field monitoring was carried out in two different assessment periods, winter and summer. The obtained results show that the CO2 concentration levels were well below the recommended limits. However, the maintenance of the recommended thermal and acoustic IEQ factors was significantly affected by the natural ventilation strategies (temperature and relative humidity values were very close to the outside values, and the background sound pressure level was over 35 dBA during the entire assessment). The proper measurements and careful selection of the appropriate ventilation scenarios become of utmost importance to ensure that the ventilation rates required by the health authorities are achieved.


2016 ◽  
Vol 20 (suppl. 5) ◽  
pp. 1521-1529
Author(s):  
Tamara Bajc ◽  
Maja Todorovic ◽  
Agis Papadopoulos

This paper presents the part of the research that has been done at the Universities both in Belgrade and Thessaloniki, Greece, taking into account indoor environmental quality in office buildings and classrooms. The measurements that are presented were done in Process Equipment Design Laboratory at Aristotle University Thessaloniki, during March 2015. Indoor environmental quality regarding air temperature, relative humidity, and CO2 concentration in two representative offices is observed. The similar offices are located one on the north-east and the other one on the south-west side of the University building, so as to be representative of the orientation?s impact. Furthermore, the impact of natural ventilation on CO2 concentration and temperature is monitored, together with the offices? occupancy. Recommended parameters for indoor air quality are compared and discussed on the base of several standards: SRPS EN 15251:2010, ASHRAE standards 55 and 62.1, and ISO 7730. The main objectives, as set from these standards are discussed, together with the investigation results.


2015 ◽  
Vol 75 (5) ◽  
Author(s):  
Ang Qiu Mei ◽  
Md Azree Othuman Mydin

This study was done to investigate the relationship between indoor environmental quality and prevalence of Sick Building Syndrome in six small offices inPenangIsland. Indoor environmental quality measurement was conducted according to relevant standards. There are totally Sixty workers were selected to participate in an electronic questionnaire survey. Questionnaire was used to record the comfort level of respondents in the case studies and level of sick building syndrome faced by respondents. Through indoor environmental quality measurement, it is found that most of the offices facing the lighting and noise problem. The result from the questionnaire shows that in overall, the occupants satisfy with their working environment in term of indoor environmental quality although the result also shows the opinions of occupants on dissatisfaction on certain indoor environmental parameter according to case study. The study also found that most of the occupants feel drowsy and fatigue when they work within the offices. Besides, due to the difference of the indoor environmental quality of the buildings, the occupants are suffered from different symptoms of the sick building syndrome.


Author(s):  
Marek Telejko ◽  
Ewa Zender-Swiercz

Most primary school buildings in Poland rely on natural ventilation. This fact is attributed to the age of these buildings constructed more than dozen or even several tens of years ago. Few of them were fitted with a mechanical ventilation system allowing for the adjustment of microclimate parameters. The national requirements for gravity ventilation provide general guidelines, specifying strict description only for the airtightness of windows and doors and the minimum airflow to be supplied to the rooms. The minimum airflow supplied is independent of the number of occupants and purpose of the room. Low indoor air quality (IAQ) can impact occupants’ health and lead to poor productivity or low academic performance. Therefore the provision of good IAQ in classrooms and laboratories is very important. This paper presents the results of the investigation devoted to the quality of indoor air in classrooms of selected Polish primary school. Six primary school in a town with a population of 200 000 inhabitants were involved in the investigations. The participating school buildings were built between 1976 and 1994 and had gravity ventilation systems. The variability of basic IAQ parameters, i.e., temperature, relative humidity and carbon dioxide level, was analysed and the assessment of the classrooms in terms of microbiological purity was performed. The outcomes confirmed the low quality of the indoor air in these buildings. The maximum value of CO2 concentration amounted to more than 4000 ppm. Certain modifications aimed at improving IAQ were proposed during the investigations. Two solutions were implemented. The results of this study indicate that the proposed solution offers the potential to improve IAQ within classrooms.


2019 ◽  
Vol 17 (1) ◽  
pp. 90-106 ◽  
Author(s):  
Syahrul Nizam Kamaruzzaman ◽  
Ainur Mardiha Azmal

Purpose This paper aims to identify the indoor environmental quality in an affordable housing, as well as the health condition of users. Furthermore, it aims to find the relationship between quality of the indoor environment (IEQ) and sick building syndrome (SBS) and the satisfaction level of the occupants towards the IEQ factor, as well as the importance of the factors in the occupants’ view. Additionally, the purpose of this pilot study is to validate the questionnaire and identify the possible outcome of this research for the main study. Design/methodology/approach There are a few methods to achieve the objective of this paper: first is by literature review and second is by a survey. There are two types of survey made: observation survey and questionnaire survey. The purpose of observation survey is to survey the surrounding and the condition of the apartments, while questionnaire survey was distributed to the respondents in the affordable housing area. Next, is analysis and discussion of the survey, and finally, summary. Findings Aside from achieving the validity of the questionnaire survey, the results of the survey have found that the respondents are dissatisfied with the noise and glare level, as well as the amount of artificial lighting in their unit. Additionally, they have rated health, ventilation and amount of air movement as the most important IEQ factors. More importantly, the occupants have experienced the symptoms of SBS and the health condition of the building occupants. The results show that the most frequent symptoms affected the respondents are fatigue, dizziness and a headache. Originality/value This paper has indicated the IEQ in the affordable housing and identifies the health risk of occupants, specifically in Malaysia.


2019 ◽  
Vol 11 (23) ◽  
pp. 6591 ◽  
Author(s):  
Lexuan Zhong ◽  
Jing Yuan ◽  
Brian Fleck

In this paper, ventilation, indoor air quality (IAQ), thermal and acoustic conditions, and lighting were studied to evaluate the indoor environmental quality (IEQ) in an institutional building at the University of Alberta in Edmonton, Canada. This study examined IEQ parameters, including pressure, illuminance, acoustics, carbon dioxide (CO2) concentration, temperature, and humidity, with appropriate monitors allocated during a lecture (duration 50 min or 80 min) in four lecture classrooms repeatedly (N = 99) from October 2018 to March 2019 with the objectives of providing a comprehensive analysis of interactions between IEQ parameters. The classroom environments were maintained at 23 ± 1 °C and 33% ± 3% RH during two-season measurements. Indoor mean CO2 concentrations were 550–1055 ppm, and a mean sound level of 58 ± 3 dBA was observed. The air change rates were configured at 1.3–6.5 per hour based on continuous CO2 measurements and occupant loads in the lectures. A variance analysis indicated that the within-lecture classroom variations in most IEQ parameters exceeded between-lecture classrooms. A multilayer artificial neural network (ANN) model was developed on the basis of feedforward networks with a backpropagation algorithm. ANN results demonstrated the importance of the sequence of covariates on indoor conditions (temperature, RH, and CO2 level): Air change rate (ACR) > room operations (occupant number and light system) > outdoor conditions.


2020 ◽  
Vol 170 ◽  
pp. 05004
Author(s):  
Anjali Jadhav ◽  
Sushma Kulkarni ◽  
Ashish Rege

India has a great cultural heritage of temples across the country. There is a wide variety of temples of variety of deities constructed from East to West and North to South of India. Most of the temples are built centuries ago and still are in good condition and the centre of cultural activities. Mahalaxmi temple precinct is a very old precinct in Kolhapur, built in 8th century by Chalukyan rulers. Every year lacs of devotees are visiting this temple of goddess Mahalaxmi from most of the part of India. The temple is constructed of basalt stone with beautiful intricate carving on it. This paper focus on indoor environmental quality of the temple which is deteriorated due to the impact of increased number of devotees. Some of the devotees face the problem of suffocation, fatigue, fainting, irritation, nasal congestion; as provision of vents are absent and natural ventilation is not available inside the shrine of goddess Mahalaxmi. Due to lack of air exchange and natural ventilation the indoor environmental quality is deteriorated. It is observed that the CO2 level is increased, decreased in O2 level, rise in temperature and humidity above the standard level causing discomfort.