scholarly journals The Effect of an Active Plant-Based System on Perceived Air Pollution

Author(s):  
Tatiana Armijos Moya ◽  
Marc Ottelé ◽  
Andy van den Dobbelsteen ◽  
Philomena M. Bluyssen

Active plant-based systems are emerging technologies that aim to improve indoor air quality (IAQ). A person’s olfactory system is able to recognize the perceived odor intensity of various materials relatively well, and in many cases, the nose seems to be a better perceiver of pollutants than some equipment is. The aim of this study was to assess the odor coming out of two different test chambers in the SenseLab, where the participants were asked to evaluate blindly the level of acceptability, intensity, odor recognition, and preference at individual level with their noses. Two chambers were furnished with the same amount of new flooring material, and one of the chambers, Chamber A, also included an active plant-based system. The results showed that in general, the level of odor intensity was lower in Chamber B than in Chamber A, the level of acceptability was lower in Chamber A than in Chamber B, and the participants identified similar sources in both chambers. Finally, the preference was slightly higher for Chamber B over Chamber A. When people do not see the interior details of a room and have to rely on olfactory perception, they prefer a room without plants.

Arsitektura ◽  
2021 ◽  
Vol 19 (2) ◽  
pp. 167
Author(s):  
Dady Wicaksono ◽  
Sugini Sugini

<p class="Abstract"><em><span lang="EN-GB">The air pollution problem had become a big problem for many cities in the world. In line with the rapid development of these cities, the concept of sustainability also continues to develop with various solutions to overcome existing problems. To solve the air pollution problem, the authors evaluated the selected building object, The Khabele School, to see the extent of the building's contribution to overcoming the air pollution problem.  The evaluation was carried out based on the DGNB (German Sustainable Building Council) certification system, the variables measured were biotope area factor (BAF), indoor air quality, daylight factor, and zero-carbon mobility. The results reveal that indoor air quality and daylight factors could meet the desired standards, while BAF and zero-carbon mobility had not met the standard. Based on theoretical and empirical studies, this paper discussed alternative design strategies, to improve the quality of the building, so that they can contribute more to overcoming air pollution problem.</span></em></p>


Author(s):  
Mohd Saleem ◽  
Mohd Adnan Kausar ◽  
Fahmida Khatoon ◽  
Sadaf Anwar ◽  
Syed Monowar Alam Shahid ◽  
...  

In many aspects of life quality, bio-contaminants and indoor air quality have had catastrophic consequences, including a negative impact on human health with an increased prevalence of allergic respiratory reactions, asthma, and infectious diseases. We aimed to evaluate the quality of indoor air environment and find out the association between human health and indoor air pollution and also to assess the physical health status of a group of Saudi and non-Saudi populations during this pandemic. Also, we aimed to assess the most common health condition or symptoms associated with ventilation. A questionnaire was distributed online to test indoor air quality, ventilation status, common signs and symptoms of any allergy or mental status and their relationship to certain variables. A total of 362 respondents were included. Before living in the current home, flu or Influenza and chapped lips were more prevalent than allergies and chapped lips signs while living in the current home. (12.2% , 10.8% vs. 18.5% , 13.55% before and after respectively) Multiple colds were the second most common symptom (10.2%). Hoarse voice and headaches were the least common symptoms experienced; each constituted 4.4%. During the COVID-19 Pandemic, most respondents wore a facemask, approximately 76.5%; and almost one-third of respondents had bright natural light inside the current home (43.1%). The presence of natural light within the current home was significantly associated with symptoms experienced during living in the current house (p<0.05). Natural sunlight exposure could decrease allergic symptoms and minor health problems associated with poor ventilation and air quality indoors. In current living homes, the majority of respondents never used air purifiers (72.9 percent). In order to get attention from people to enhance the quality and ventilation mechanism of indoor air, special care and awareness of the effects of the use of air purifiers on human health is needed.


2014 ◽  
Vol 26 (6) ◽  
pp. 688 ◽  
Author(s):  
Jung Im Na ◽  
Sang Young Byun ◽  
Mi Young Jeong ◽  
Kyoung Chan Park ◽  
Chang Hun Huh

Atmosphere ◽  
2019 ◽  
Vol 10 (12) ◽  
pp. 742 ◽  
Author(s):  
Ewa Brągoszewska ◽  
Magdalena Bogacka ◽  
Krzysztof Pikoń

Air pollution, a by-product of economic growth, generates an enormous environmental cost in Poland. The issue of healthy living spaces and indoor air quality (IAQ) is a global concern because people spend approximately 90% of their time indoors. An increasingly popular method to improve IAQ is to use air purifiers (APs). Indoor air is often polluted by bioaerosols (e.g., viruses, bacteria, fungi), which are a major concern for public health. This work presents research on culturable bacterial aerosol (CBA) samples collected from dwellings with or without active APs during the 2019 summer season. The CBA samples were collected using a six-stage Andersen cascade impactor (ACI). The CBA concentrations were expressed as Colony Forming Units (CFU) per cubic metre of air. The average concentration of CBA in dwellings when the AP was active was 450–570 CFU/m3, whereas the average concentration when the AP was not active was 920–1000 CFU/m3. IAQ, when the APs were active, was on average almost 50% better than in cases where there were no procedures to decrease the concentration of air pollutants. Moreover, the obtained results of the particle size distribution (PSD) of CBA indicate that the use of APs reduced the proportion of the respirable fraction (the particles < 3.3 µm) by about 16%. Life cycle assessment (LCA) was used to assess the ecological cost of air purification. Our conceptual approach addresses the impact of indoor air pollution on human health and estimates the ecological cost of APs and air pollution prevention policies.


2016 ◽  
Vol 89-90 ◽  
pp. 138-146 ◽  
Author(s):  
Zheming Tong ◽  
Yujiao Chen ◽  
Ali Malkawi ◽  
Gary Adamkiewicz ◽  
John D. Spengler

10.14311/492 ◽  
2003 ◽  
Vol 43 (6) ◽  
Author(s):  
M. V. Jokl

Human physiology research makes evident that the Weber-Fechner law applies not only to noise perception but also to the perception of other environmental components. Based on this fact, new decibel units for dor component representing indoor air quality in majority locations have been proposed: decicarbdiox dCd (for carbon dioxide CO2) and decitvoc dTv (for total volatile organic compound TVOC). Equations of these new units have been proved by application of a) experimental relationships between odor intensity (representing odor perception by the human body) and odor concentrations of CO2 and TVOC, b) individually  measured CO2 and TVOC levels (concentrations) – from these new decibel units can be calculated and their values compared with decibel units of noise measured in the same locations. The undoubted benefit of using the decibel scale is that it gives much better approximation to human perception of odor intensity compared to the CO2 and TVOC concentration scales.


2020 ◽  
Author(s):  
Fritz Nieborowski

&lt;div&gt; &lt;p&gt;Improper ventilation of buildings may lead to an accumulation of pollutants indoors. In the case of a room with forced air ventilation and external air intake like most centralized and some home air conditioning units, this study will show CFD simulations of various indoor air quality conditions based on different forced ventilation AC unit intake conditions like common in housing situations like Hong Kong. Especially when close to roadways or other external pollution sources, the positioning of the air intake shows up to have a high significance for the infiltration rate resulting as influence for the indoor air quality as previous research shows (e.g. Zheming Tong et al., 2016). The same is the case for a forced ventilation case like air conditioning units with outside air intake. Research like earlier referenced paper has not been conducted with higher buildings or forced air intake yet. Parametrized CFD-based air quality models with using OpenFoam will be employed to quantify the impact of the air intake location and rate in a 2-dimensional interface on the indoor air quality of a forced ventilated section of a building. The findings of the CFD simulation will be simplified as average indoor air pollution and other external factors. As an approach to predict the estimate indoor infiltration rate, an ANN (Artificial Neuronal Network) will be used, trained and validated with said data. The neural network is supposed to predict the pollutant intake based on fewer and as easier to obtain meteorological parameters and air pollution data. Finally, the ANN predictions of the models will be verified with real life data from other papers. Results will show that a major part of indoor pollutants may emerge indoors and cannot be neglected. In comparison with real life data, it seems the model lacks significant input to predict with high accuracy.&amp;#160;&lt;/p&gt; &lt;/div&gt;