scholarly journals Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics

2021 ◽  
Vol 10 (15) ◽  
pp. 3268
Author(s):  
Ladislav Viktor Nováček ◽  
Marie Němcová ◽  
Kateřina Tyx ◽  
Kristýna Lahodová ◽  
Leoš Rejmont ◽  
...  

This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)—the Liberty® 677MY or the AT LISA® tri 839M—in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome ±0.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20/20 uncorrected distance visual acuity (UDVA) and 20/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs.

2017 ◽  
Vol 27 (4) ◽  
pp. 460-465 ◽  
Author(s):  
Ramón Ruiz-Mesa ◽  
Antonio Abengózar-Vela ◽  
Ana Aramburu ◽  
María Ruiz-Santos

Purpose To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal. Methods Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire. Results The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05). Conclusions Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.


2021 ◽  
Vol 14 (3) ◽  
pp. 371-377
Author(s):  
Hui Liu ◽  
◽  
Hai-Jun Xia ◽  
Jin Zhou ◽  
◽  
...  

AIM: To analyze postoperative clinical results after implantation of trifocal intraocular lenses (IOLs) in highly myopic eyes with different axial lengths (ALs). METHODS: This retrospective study describes 61 eyes of 44 patients that were implanted with trifocal diffractive IOLs (AT LISA tri 839MP). Twenty-one eyes (15 patients) were included in the AL<26 mm group, 19 eyes (13 patients) in the AL≥26 mm and <28 mm group, and 21 eyes (16 patients) in the AL≥28 mm group. Postoperative outcomes, including corrected and uncorrected distance visual acuity (UDVA), intermediate and near visual acuity at 167 cd/m2 luminance, depth of focus at 85 cd/m2 luminance, and objective optical quality parameters assessed using the Optical Quality Analysis System (OQAS), were compared among the groups at 3mo. RESULTS: There were no significant differences in the mean UDVA, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (DCNVA) among the three groups (P>0.05). Better near and intermediate visual acuity (from -1.5 D to -3.0 D) were noted on the defocus curve of the AL<26 mm group (P<0.01 vs AL≥28 mm group). Significantly higher objective scatter index (OSI) values and lower modulation transfer function (MTF) cut-off values, Strehl ratio (SR), and OQAS values (OVs) were observed in the AL≥28 mm group (P<0.01 vs AL<26 mm group). All OQAS parameters had statistically significant correlations with DCNVA and visual acuity at the vergence of -2.5 D (P<0.05 to P<0.01). CONCLUSION: Implantation of trifocal IOLs provides good short-term visual and refractive outcomes in highly myopic eyes with different ALs. However, the near vision decreases in the extremely myopic eyes at lower luminance, which is associated with the lower objective optical quality in these eyes.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Florian T. A. Kretz ◽  
Detlev Breyer ◽  
Vasilios F. Diakonis ◽  
Karsten Klabe ◽  
Franziska Henke ◽  
...  

Purpose.To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation.Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec). Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated.Results.Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better.Conclusions.Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction.


2019 ◽  
Author(s):  
Jae Hyuck Lee ◽  
Hun Lee ◽  
Jin Ah Lee ◽  
Aeri Yoo ◽  
Jae Yong Kim ◽  
...  

Abstract Background To evaluate the clinical outcomes of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses (IOLs) with different add powers. Methods We retrospectively reviewed the medical records of 18 patients who underwent bilateral mix-and-match implantation of diffractive multifocal IOLs with different add powers. Multifocal IOLs with add powers of +2.75 diopters (D) and +4.00 D were implanted into the patients’ dominant and nondominant eyes, respectively. At 1 and 3-month postoperatively, monocular and binocular visual acuity was measured using logMAR charts and manifest refraction was performed. Specifically, logMAR charts were used to measure uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and corrected distance visual acuity (CDVA). Defocus curves, contrast sensitivity, and patient satisfaction were assessed at 3-month postoperatively. Results Binocular logMAR measurements (mean ± standard deviation) at 3-month postoperatively were 0.01±0.04 (UDVA), 0.16±0.05 (UIVA), and 0.11±0.07 (UNVA). Postoperative spherical equivalent was -0.43±0.35 D and -0.39±0.21 D in the dominant and nondominant eyes, respectively. Defocus curves showed significant differences between -1.50 and -4.00 D among binocular, dominant, and nondominant eye measurements, except between -2.50 and -3.00 D. Eyes implanted with +2.75 and +4.00 D IOLs showed good contrast sensitivity under photopic and mesopic conditions. Over 80% of patients reported high satisfaction with their near vision. Conclusions Bilateral mix-and-match implantation of diffractive multifocal IOLs with add powers of +2.75 D and +4.00 D showed good near, intermediate, and far vision.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Sri Ganesh ◽  
Sheetal Brar ◽  
Archana Pawar ◽  
Kirti J. Relekar

Purpose. To evaluate the outcomes following bilateral ERV intraocular lens implantation with micromonovision.Methods. 25 subjects underwent bilateral Tecnis Symfony IOL implantation with micromonovision. The dominant eye was targeted for emmetropia and the nondominant eye for myopia of −0.75 D. Uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CIVA), and near visual acuity (UNVA, DCNVA); reading performance; defocus curve; and contrast sensitivity were studied. Follow-ups were conducted at 1 week and 1 and 6 months postoperatively.Results. At 6 months postoperatively, the mean binocular UDVA, CDVA, UNVA, and DCNVA were −0.036 ± 0.09, −0.108 ± 0.07, 0.152 ± 0.11, and 0.216 ± 0.10 logMAR, respectively. Binocular UIVA and DCIVA were 0.048 ± 0.09 and 0.104 ± 0.08 logMAR, respectively, at 60 cm and −0.044 ± 0.09 and 0.012 ± 0.09 logMAR, respectively, at 80 cm. All patients had ≥0.2 logMAR UDVA and UNVA. Reading acuity and reading speeds showed improvement over time. Between defocus range of −2.50 and +1.00 D, the visual acuity remained ≥0.2 logMAR. Contrast sensitivity scores were within the normal range. 4 patients used reading glasses for very fine print.Conclusion. Bilateral ERV IOL implantation leads to excellent outcomes for far and intermediate vision, satisfactory outcomes for near vision, and good tolerance to micromonovision at the end of the 6 months. This trial is registered withCTRI/2015/10/006246.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Hirotaka Tanabe ◽  
Hitoshi Tabuchi ◽  
Tomohiro Shojo ◽  
Tomofusa Yamauchi ◽  
Kosuke Takase

Abstract To compare the visual performance of a monofocal intraocular lens (IOL) (ZCB00) and a multifocal IOL (ZMB00) of the same material and basic design, we evaluated postoperative parameters at 10 weeks after the last surgery in cataract patients who underwent bilateral ZCB00 or ZMB00 implantation from December 13, 2010, to July 29, 2019, with the right and left lenses implanted within 3 months of each other. The study enrolled 2,230 eyes of 1,115 patients. The monofocal group comprised 904 eyes of 452 patients (72.3 ± 6.8 years; females/males, 268/184), and the multifocal group comprised 1,326 eyes of 663 patients (67.0 ± 7.8 years; females/males, 518/145). Contrast sensitivity (4.0/2.5/1.6/1.0/0.7 degrees), contrast sensitivity with glare (1.6/1.0/0.7 degrees), and the VFQ-25 score for driving at night were significantly better in the monofocal group (p < 0.00068, Wald test). Uncorrected intermediate/near visual acuity and near spectacle independence were significantly better in the multifocal group (p < 0.00068, Wald test). The two IOL groups had different characteristics in terms of contrast sensitivity, night-time driving, uncorrected intermediate/near visual acuity and near spectacle independence.


2016 ◽  
Vol 27 (1) ◽  
pp. 26-30 ◽  
Author(s):  
Jose M. Martinez-de-la-Casa ◽  
Jesús Carballo-Alvarez ◽  
Javier Garcia-Bella ◽  
Jose M. Vazquez-Molini ◽  
Laura Morales ◽  
...  

Purpose To assess photopic and mesopic vision in patients implanted with 2 different trifocal intraocular lenses (IOLs). Methods Fifty patients with cataract in both eyes had surgery with bilateral implantation of a trifocal FineVision (FV, n = 25) or AT LISA tri 839MP (LisaTri, n = 25) IOL. Three months after surgery, high-contrast photopic uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were determined using the Early Treatment Diabetic Retinopathy Study test. Intermediate (65 cm) and near (40 cm) visual acuity were also measured, both with best distance correction (DCIVA and DCNVA, respectively). The CSV1000 test chart was used for binocular and monocular contrast sensitivity. Defocus curves were constructed under photopic and mesopic conditions. Results Mean patient age was 68.4 ± 5.5 years (FV) and 67.3 ± 5.6 years (LisaTri) (p = 0.540). No differences were found in terms of visual acuity between the groups. The CDVA, DCIVA, and DCNVA were 0.05 ± 0.06, 0.25 ± 0.10, and 0.13 ± 0.10 logMAR for FV and -0.04 ± 0.11, 0.32 ± 0.09, and 0.12 ± 0.11 logMAR for LisaTri, respectively (p = 0.09, p = 0.08, and p = 0.12). Photopic and mesopic defocus curves were comparable between the 2 IOL groups (p>0.05). Mesopic values were significantly worse than photopic in both groups for all the measured values (p<0.001). No differences in contrast sensitivity were observed between the 2 IOL groups (p>0.05). Conclusions Both trifocal diffractive IOLs provided good visual quality with a statistically significant decrease in mesopic conditions.


2019 ◽  
Vol 30 (2) ◽  
pp. 299-306 ◽  
Author(s):  
Irene Altemir-Gomez ◽  
Maria S Millan ◽  
Fidel Vega ◽  
Francisco Bartol-Puyal ◽  
Galadriel Gimenez-Calvo ◽  
...  

Objective: To compare visual quality in patients implanted with Tecnis® monofocal (ZCB00) and multifocal (ZMB00) intraocular lenses taking into account their optical quality measured in vitro with an eye model. Methods: In total, 122 patients participated in this study: 44 implanted with monofocal and 78 with multifocal intraocular lenses. Measurements of visual acuity and contrast sensitivity were performed. The optical quality of the intraocular lenses was evaluated in three image planes (distance, intermediate and near) using an eye model on a test bench. The metric considered was the area under the curve of the modulation transfer function. Results: Optical quality at the far focus of the monofocal intraocular lens (area under the curve of the modulation transfer function = 66.97) was considerably better than that with the multifocal lens (area under the curve of the modulation transfer function = 32.54). However, no significant differences were observed between groups at the distance-corrected visual acuity. Distance-corrected near vision was better in the multifocal (0.15 ± 0.20 logMAR) than that in the monofocal group (0.43 ± 0.21 logMAR, p < 0.001), which correlated with the better optical quality at near reached by the multifocal intraocular lens (area under the curve of the modulation transfer function = 29.11) in comparison with the monofocal intraocular lens (area under the curve of the modulation transfer function = 5.0). In intermediate vision, visual acuity was 0.28 ± 0.16 logMAR (multifocal) and 0.36 ± 0.14 logMAR (monofocal) with p = 0.014, also in good agreement with the values measured in the optical quality (area under the curve of the modulation transfer function = 10.69 (multifocal) and 8.86 (monofocal)). The contrast sensitivity was similar in almost all frequencies. Pelli–Robson was slightly better in the monofocal (1.73) than in the multifocal group (1.64; p = 0.023). Conclusion: Patients implanted with multifocal ZMB00 achieved a distance visual acuity similar to those implanted with monofocal ZCB00, but showed significantly better intermediate and near visual acuity. A correlation was found between intraocular lenses’ optical quality and patients’ visual acuity. Contrast sensitivity was very similar between the multifocal and monofocal groups.


2011 ◽  
Vol 21 (6) ◽  
pp. 732-740
Author(s):  
Yanwen Fang ◽  
Yi Lu ◽  
Xinhua Wu ◽  
Aizhu Miao ◽  
Yi Luo

Purpose. To evaluate and compare the objective and subjective visual function after implantation of 2 aspheric intraocular lenses (IOLs) in Chinese cataract patients. Methods. Forty-one eyes of 28 patients with cataract were randomly assigned to receive either the MC X11 ASP IOL or the AcrySof IQ IOL. Three months postoperatively, best-corrected visual acuity (BCVA), contrast sensitivity, wavefront aberrations, and subjective visual quality were measured. The degree of posterior capsule opacification (PCO) was recorded at last follow-up. Results. Postoperative mean monocular BCVA was 0.05±0.13 logMAR in the MC X11 group and 0.05±0.08 logMAR in the IQ group. There was no significant difference in visual acuity, contrast sensitivity, subjective visual quality, and degree of PCO between the 2 groups. For a 6-mm pupil diameter, the mean spherical aberration (Z40) was 0.075±0.076 μm in the MC X11 group and 0.056±0.111 μm in the IQ group. However, 45.5% and 57.9% of the eyes in the MC X11 and IQ groups had values >0.10 μm, respectively. The mean RMS values of the high-order aberrations were similar between the 2 groups except the higher fifth- and sixth-order aberrations, which were significantly higher in the MC X11 group. Conclusions. Both IOLs provided similar and good visual outcomes. However, the data suggest that the amount of negative spherical aberration generated by current available aspheric IOLs might not be optimal for Chinese eyes.


Sign in / Sign up

Export Citation Format

Share Document