scholarly journals Bonding Performance of Universal Adhesives Applied to Nano-Hydroxyapatite Desensitized Dentin Using Etch-and-Rinse or Self-Etch Mode

Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4746
Author(s):  
Yuchen Meng ◽  
Fan Huang ◽  
Silin Wang ◽  
Meiwen Li ◽  
Yi Lu ◽  
...  

The study assessed the bonding performance of three universal adhesives on desensitized dentin with etch-and-rinse mode or self-etch mode after nano-hydroxyapatite (nHAp)-based desensitizers application. Simulated sensitive dentin specimens were prepared and separated into four groups: no treatment as the negative control, groups desensitized by Biorepair toothpaste, Dontodent toothpaste, or nHAp paste. Three universal adhesives of All-Bond Universal, Single Bond Universal, and Clearfil Universal Bond with etch-and-rinse or self-etch mode were bonded to the desensitized dentin specimens separately, followed by resin composite build-ups. Micro-tensile bond strength was measured using a micro-tensile tester. The wettability of desensitized dentin was evaluated by the contact angle of the adhesives. Resin infiltration was observed by confocal laser scanning microscopy. Dentin tubular occlusion and nanoleakage were observed by scanning electron microscope. The results showed that the etch-and-rinse or self-etch mode of each adhesive showed similar bond strength when bonding to nHAp-based desensitized dentin. The dentin surface was partially covered by desensitizers after desensitization. Compared with the self-etch mode, stronger demineralization and more reopened dentin tubules were observed in the etch-and-rinse mode after acid etching; longer resin tags and more nanoleakage in the resin–dentin interface were observed when using the etch-and-rinse mode. When bonding to nHAp-based desensitized dentin with universal adhesives, no significant difference in bond strength was found between self-etch mode or etch-and-rinse mode; while the latter produced more nanoleakage in the resin–dentin interfaces.

2020 ◽  
Author(s):  
Shuangfeng Liu ◽  
Yanxia Zhu ◽  
Tana Gegen

Abstract The objective of this study was to analyze morphologically the all-etching bonding system and self-etching bonding system for enamel with different degrees of fluorosis and evaluate the bond strength of each system. Teeth that were indicated for extraction owing to orthodontic or periodontal problems were selected. According to Dean’s index and the Thylstrup-Fejerskov index, 180 extracted teeth were divided into three groups of mild, moderate, and severe dental fluorosis (DF), with 60 teeth in each group. The teeth in each group were randomly divided into two subgroups (n = 30), which were then subjected to the all-etching bonding system (Prime & Bond NT) and self-etching bonding system (SE-Bond). Each group of adhesives was used to bond Z350 universal resin (3M) to the etched dental enamel. Tensile and shear tests were conducted to determine the bond strength. Subsequently, the fractured specimens were investigated using scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). The Prime & Bond NT was statistically significant for the tensile and shear strength of enamel with mild fluorosis (P < 0.05) but did not exhibit a significant difference for moderate and severe DF (P > 0.05). The SE-Bond was not statistically significant for the tensile and shear strength of mild, moderate, or severe DF (P > 0.05). The SEM and CLSM results reveal that the mild fluorosis enamel crystals were relatively dense, and a small amount of resin remained. The moderate fluorosis enamel crystals were loosely arranged, and the gaps were widened. The severe fluorosis enamel crystals were irregularly arranged. The disorder was aggravated, and the dentinal orifice was exposed by partial enamel exfoliation. The bonding strength of mild fluorosis enamel with the Prime & Bond NT was better than that with the SE-Bond, and cohesive failure was the most common mode of failure. Because there was no difference in the bonding strength of the SE-Bond for different degrees of DF, we recommend the use of the all-etching adhesive system in the clinical treatment of teeth with mild fluorosis.


2019 ◽  
Vol 30 (6) ◽  
pp. 555-562
Author(s):  
Maybell Tedesco ◽  
Marcelo Carvalho Chain ◽  
Wilson Tadeu Felippe ◽  
Ana Maria Hecke Alves ◽  
Lucas da Fonseca Roberti Garcia ◽  
...  

Abstract This study correlated the bond strength (BS) and dentin penetration of different sealers by push-out test and Confocal Laser Scanning Microscopy (CLSM) analysis. Forty-five root canals were prepared according to the crown-down technique and filled with gutta-percha associated to the following sealers (n=15): Endofill, AH Plus and MTA Fillapex. Five canals of each group were filled with the sealers added with 0.1% Rhodamine B dye. Next, the specimens were transversely sectioned and submitted to the push-out test (n=10) and CLSM analysis (n=5). The BS data showed the following means (MPa) and standard deviation: AH Plus (4.17±1.86); MTA Fillapex (3.13±1.96) and Endofill (2.10±1.03). Statistical analysis (two-way ANOVA, α=0.05) showed significant difference among sealers (p<0.001) and root canal thirds (p<0.001). The BS results of Endofill and MTA Fillapex were statistically similar (p>0.05), however, they were statistically different from AH Plus (p<0.001). The regional analysis of BS showed similarity between middle and apical thirds (p>0.05), and both were different from coronal portion (p<0.001). CLSM analysis verified tags formation in all groups and higher penetration of the specimens filled with AH Plus (p<0.05). The Kendall test (correlation between BS to dentin and sealer penetration into dentinal tubules) and the Pearson test (between failures pattern and sealer penetration into dentinal tubules) did not show correlation between the variables evaluated for all the tested sealers (p>0.05). AH Plus group had higher BS to dentin, and deeper tags formation than the other sealers. There was no significant correlation between BS and intratubular penetration of the tested sealers.


2019 ◽  
Vol 30 (5) ◽  
pp. 467-475 ◽  
Author(s):  
Gabriela Cardoso de Cardoso ◽  
Leina Nakanishi ◽  
Cristina Pereira Isolan ◽  
Patrícia dos Santos Jardim ◽  
Rafael Ratto de Moraes

Abstract This study evaluated the immediate and 6-month dentin bond strength of universal adhesives used in etch-and-rinse or self-etch bonding strategies. The adhesives tested were Ambar Universal, G-Bond, Single Bond Universal, Tetric N-Bond Universal, and Ybond Universal. Gold standard adhesives (Scotchbond Multipurpose Plus and Clearfil SE Bond) were controls. Microtensile dentin bond strength (n=5 teeth), pH, and C=C conversion (n=3) were evaluated. Data were analyzed at α=0.05. All adhesives showed differences in pH. Ybond had intermediately strong aggressiveness, whereas the others were ultra-mild. The C=C conversion was different in most adhesives. In the etch-and-rinse strategy, all adhesives showed similar results generally except for G-Bond, which had lower bond strength than most adhesives. G-Bond and Tetric-N-Bond showed lower bond strengths after 6 months compared with 24 h, whereas the other adhesives had stable dentin bonds. In the self-etch strategy, G-Bond had lower bond strength than most adhesives. After 6 months, Ambar was the only adhesive showing lower dentin bond strength compared with 24 h. Most adhesives had discreet drops in bond strength during aging when used in the self-etch strategy. The failure modes were also material dependent, with a general pattern of increased adhesive and/or pre-testing failures after storage. In conclusion, the bonding performance of universal adhesives to dentin is material dependent. Most adhesives had stable dentin bonds with results comparable to the gold standard materials, particularly when applied in the self-etch mode. In general, it seems the use of universal adhesives in dentin should not be preceded by phosphoric acid etching.


2012 ◽  
Vol 37 (6) ◽  
pp. 610-616 ◽  
Author(s):  
RL Quock ◽  
JA Barros ◽  
SW Yang ◽  
SA Patel

SUMMARY The aim of this in vitro study was to investigate the effect of the cariostatic and preventive agent silver diamine fluoride (SDF) on the microtensile bond strength of resin composite to dentin. Forty-two caries-free, extracted molars were flattened occlusally and apically using a diamond saw, and the exposed occlusal dentin was polished with a series of silicon carbide papers, all under water irrigation. The teeth were then randomly divided into six groups of seven teeth each that were treated as follows: 1) Peak SE self-etch bonding agent; 2) 12% SDF + Peak SE; 3) 38% SDF + Peak SE; 4) Peak LC etch-and-rinse bonding agent; 5) 12% SDF + Peak LC; and 6) 38% SDF + Peak LC. Four-millimeter buildups of Amelogen Plus were incrementally placed on all teeth; after a 24-hour storage period in distilled water, the specimens were sectioned perpendicular to the adhesive interface to produce beams of cross-sectional surface area measuring approximately 1 mm2. The beams were placed on a microtensile testing machine, which utilized a single-speed pump motor and force gauge at 20 kgf × 0.01 second to record maximum tensile force before failure occurred. Two-way analysis of variance and post hoc Tukey tests were performed to compare the effects of the SDF on microtensile bond strength, with statistical significance set at α = 0.05. None of the experimental groups treated with different concentrations of SDF showed a significant difference in bond strength compared to the control groups, and there was no significant difference in bond strength between self-etch and etch-and-rinse groups. However, the effect of SDF on self-etch bonded teeth compared to etch-and-rinse bonded teeth was statistically significant (p=0.0363), specifically at the 12% concentration. SDF does not adversely affect the bond strength of resin composite to noncarious dentin.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2021 ◽  
Author(s):  
TP Leandrin ◽  
E Fernández ◽  
RO Lima ◽  
JF Besegato ◽  
WG Escalante-Otárola ◽  
...  

SUMMARY Objective: This study aimed to evaluate the effect of fiber post customization on the bond strength (24 hours and 6 months), resin cement thickness, and dentinal penetrability of Adper Scotchbond Multi-Purpose – RelyX ARC (AS-RA), RelyX U200 (R2), and Scotchbond Universal – RelyX Ultimate (SU-RU) cementation systems to root dentin from the cervical-, middle-, and apical-thirds of the post space. Methods: One hundred twenty bovine incisors were endodontically treated. After post space preparation, the roots were divided into six groups, according to the luting protocols (AS–RA, R2, SU– RU) and the type of fiber post [noncustomized post (NC) and customized post (C)]. Customization procedures were peformed using a resin composite (Z350 XT). 24 hours (n=60) or 6 months later (n=60), specimens from the cervical-, middle-, and apical-thirds of the post space were submitted to cementation system thickness measurement, bond strength evaluation, and dentinal penetrability analysis with Confocal Laser Scanning Microscopy (CLSM). Failure mode was classified as adhesive, cohesive, or mixed. Data were submitted to ANOVA and Tukey tests (α=0.05). Results: Cementation protocols with customized fiber posts presented the lowest cementation system thickness, regardless of the cementation system or post space-third (p&lt;0.05), and the highest bond strength values (p&lt;0.05), regardless of the third space (p&gt;0.05), for both periods (24 hours or 6 months). The comparison of push-out bond strength values between 24 hours and 6 months showed a reduction in all groups for the cervical-third (p&lt;0.05). For the middle-third, only noncustomized groups showed reduction (p&lt;0.05). For the apical-third, no reduction was observed (p&gt;0.05). Conclusions: Anatomical customization favored both the bond strength of cements to dentin and the dentinal penetrability, but with lower cementation system thickness, regardless of cement composition and adhesive strategy.


2016 ◽  
Vol 41 (5) ◽  
pp. 520-530 ◽  
Author(s):  
T Suzuki ◽  
T Takamizawa ◽  
WW Barkmeier ◽  
A Tsujimoto ◽  
H Endo ◽  
...  

SUMMARY The purpose of this study was to determine the enamel bond durability of three universal adhesives in different etching modes through fatigue testing. The three universal adhesives used were Scotchbond Universal, Prime&Bond Elect universal dental adhesive, and All-Bond Universal light-cured dental adhesive. A single-step self-etch adhesive, Clearfil S3 Bond Plus was used as a control. The shear bond strength (SBS) and shear fatigue strength (SFS) to human enamel were evaluated in total-etch mode and self-etch mode. A stainless steel metal ring with an internal diameter of 2.4 mm was used to bond the resin composite to the flat-ground (4000-grit) tooth surfaces for determination of both SBS and SFS. For each enamel surface treatment, 15 specimens were prepared for SBS and 30 specimens for SFS. The staircase method for fatigue testing was then used to determine the SFS of the resin composite bonded to the enamel using 10-Hz frequencies for 50,000 cycles or until failure occurred. Scanning electron microscopy was used to observe representative debonded specimen surfaces and the resin-enamel interfaces. A two-way analysis of variance and the Tukey post hoc test were used for analysis of the SBS data, whereas a modified t-test with Bonferroni correction was used for the SFS data. All adhesives in total-etch mode showed significantly higher SBS and SFS values than those in self-etch mode. Although All-Bond Universal in self-etch mode showed a significantly lower SBS value than the other adhesives, there was no significant difference in SFS values among the adhesives in this mode. All adhesives showed higher SFS:SBS ratios in total-etch mode than in self-etch mode. With regard to the adhesive systems used in this study, universal adhesives showed higher enamel bond strengths in total-etch mode. Although the influence of different etching modes on the enamel-bonding performance of universal adhesives was found to be dependent on the adhesive material, total-etch mode effectively increased the enamel bond strength and durability, as measured by fatigue testing.


2021 ◽  
Vol 20 ◽  
Author(s):  
Amany A. Salem ◽  
Mohamed S. Nassif ◽  
Dalia I. El-Korashy

Aim. To evaluate the bond durability of two universal adhesives; mild and ultra-mild in both etch-and-rinse and self-etch modes after simulated in-vitro degradation by long-term water storage or thermocycling. Methods. A total of 144 specimens were used in this study; 120 specimens (prepared from 30 teeth) for microshear bond strength testing and fracture mode assessment, and 24 specimens for scanning electron microscopic evaluation (prepared from 24 teeth). Specimens were prepared from 54 recently extracted caries free third molars and randomly divided into 12 groups, according to the adhesive treatment (All Bond or Scotchbond Universal), etching mode (etch-andrinse or self-etch) and aging method (thermocycling or water storage). Each tooth was sectioned mesio-distally into two halves exposing free dentin surface for bonding where dentin substrate 1 mm below the dentino-enamel junction was used. After adhesive application and composite build up, specimens were tested in shear mode after storing in distilled water at 37˚C for 24 hours or 1 year, or after being thermocycled between 5 and 55 °C for 10,000 cycles (n=10). Microshear bond strength (μSBS) was tested using a universal testing machine. Adhesive-dentin interface was examined using scanning electron microscope (SEM) (n=2). Data were analyzed using 3 way AN0VA and pairwise comparisons was performed using Bonferroni correction at significance level of α ≤0.05. Results. Statistical analysis revealed non-significant difference for etching mode in both adhesives (p=0.596). After aging, the bond strength was only reduced in Scotchbond Universal after one year of water storage in both modes (p<0.001). SEM evaluation revealed intact hybrid layer and longer resin tags for etch-and-rinse mode than selfetch mode of both adhesives. Conclusion. The bond strength of universal adhesives is not affected by the etching mode, however its durability was shown to be material dependent.


2019 ◽  
Vol 10 (1) ◽  
pp. 124 ◽  
Author(s):  
Anna Zecin-Deren ◽  
Monika Lukomska-Szymanska ◽  
Agata Szczesio-Wlodarczyk ◽  
Ireneusz Piwonski ◽  
Jerzy Sokolowski ◽  
...  

Contemporary adhesives use etch-and-rinse, self-etch, and multimode adhesive strategies. Simplified and universal adhesives present lower bond strength to dentin than conventional, two-bottle etch-and-rinse adhesives. The purpose of this study was to evaluate bonding performance of simplified and universal adhesives to dentin after modifying their application protocol (multiplying applications and extending application time). Adhesive layer thickness (ALT) and shear bond strength (SBS), as well as the correlation between these parameters was calculated. Two universal (Single Bond Universal and Prime & Bond One Select) and two self-etch adhesives (Adper Easy One and Xeno V) were tested. Significant differences in ALT were detected between the adhesives, as well as within the same adhesive between study groups. Tested adhesives presented the thinnest adhesive layer when applied 2 times in 20 s. Single Bond Universal obtained the highest SBS results of all adhesives. Most adhesives (except for Prime & Bond One Select) obtained the highest SBS, when applied two or three times in 40 or 60 s, respectively. No correlation between the ALT and SBS was found. The study showed that increasing the number of applications and extending the application time of self-etch and universal adhesives can be recommended to improve their performance.


2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Fateme Vasei ◽  
Farahnaz Sharafeddin

Objective: To assess the shear bond strength (SBS) of resin composite to deep dentin, using 1 and 2.5% chitosan pretreatment as well as different adhesive systems. Material and Methods: 80 human maxillary molars were randomly divided to eight groups according to the type of adhesive system and dentin pretreatment (n = 10): I) two-step self-etch system (Clearfil SE bond); II) two-step etch-andrinse system (Adper single bond 2); III) 2.5% chitosan + Clearfil SE bond; IV) 2.5% chitosan +etch + Adper single bond 2; V) etch + 2.5% chitosan + Adper single bond 2; VI) 1% chitosan + Clearfil SE bond; VII) 1% chitosan + etch + Adper single bond 2; VIII) etch + 1% chitosan + Adper single bond 2 (chitosan solution (w/v): 2.5 g and 1 g of chitosan (Sigma Aldrich, USA) was dissolved in 100 ml of 1% acetic acid). Plastic molds were positioned on dentin and filled with composite (Z350, 3M ESPE, USA). SBS (MPa) was tested using a universal testing machine. ANOVA tests, Tukey’s test, and independent t test were used to analyze data (p < 0.05). Results: The highest SBS value among self-etch groups was observed with 1% chitosan (p = 0.001). In the etch-and-rinse group, the SBS of 1% chitosan was significantly lower than the other groups. Chitosan treatment following acid etching led to higher SBS in comparison to when chitosan was applied before etching, with the significant difference in 1% concentration (p = 0.030). A predominance of mix fractures was observed in dentin. Conclusion: Improved dentin bond strength can be achieved through immediate dentin pretreatment with 1% chitosan in self-etch adhesive systems. Chitosan Pretreatment may not be advantageous for etch-and-rinse adhesive systems. Keywords Adhesive system; Chitosan; Deep dentin; Shear strength.


Sign in / Sign up

Export Citation Format

Share Document