scholarly journals Tunable Stiffness and Damping Study on Flexible PVC Cantilever Structure Embedded with MR Fluid

Materials ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5024
Author(s):  
Gunasekaran Ramkumar ◽  
Arul Jesu Gnanaprakasam ◽  
Marimuthu Thirumarimurugan

The stiffness and damping of a flexible smart cantilever structure controlled by a magnetic field is investigated in this research. The cantilever structure is fabricated by using flexible polyvinyl chloride as a host structure of rectangular cross-section embedded with magnetorheological (MR) fluid. The deflection of the cantilever structure at the free end is used to analyze the stiffness change of the cantilever structure. The stiffness of the specimen with MR fluid at magnetic flux density of 0.171T is greater than that of the specimen without subjected to magnetic field. The strength of the applied magnetic field is directly related to the structure’s stiffness. Under the influence of a magnetic field, the MR fluid embedded inside the flexible PVC cantilever structure significantly dampens the vibrations of the structure.

Author(s):  
Ping-Hsun Lee ◽  
Jen-Yuan (James) Chang

Abstract In this paper we proposed a platform for measuring shear force of magnetorheological (MR) fluid by which the relationship of yield stress and magnetic flux density of specific material can be determined. The device consisted of a rotatable center tube in a frame body and the magnetic field was provided by two blocks of permanent magnets placed oppositely outside the frame body. The magnitude and direction of the magnetic field were manipulated by changing the distance of the two permanent magnets from the frame body and rotating the center tube, respectively. For determining the magnetic field of the device, we adopted an effective method by fitting the FEM (finite element method) result to the measured one and then rebuilt the absent components to approximate the magnetic field, which was hardly to be measured simultaneously as different device setup were required. With the proposed platform and analytical methods, the drawing shear force and the corresponding yield stress contributed by MR fluid could be evaluated in respect to the magnitude and direction of given magnetic flux density with acceptable accuracy for specific designing purposes without a large, complex, and expensive instrument.


2019 ◽  
Vol 82 (1) ◽  
Author(s):  
Ayob Nazmy Nanyan ◽  
Mohamad Nur Khairul Hafizi Rohani ◽  
Muzamir Isa ◽  
Afifah Shuhada Rosmi ◽  
Ahmad Zaidi Abdullah ◽  
...  

Overvoltage phenomenon is the common problem that always occurs in the power system and can cause the electrical system network breakdown, and in some cases, it may explode. The frequent overvoltage also can affect and degrade the lifespan of the electrical power system components and network. Thus, the overvoltage sensor is needed to overcome this problem matter. The Rogowski coil (RC) is one of an inductive coil group, and it is suitable for measuring the alternating current (AC) and transient currents or overvoltage. This paper demonstrated the effect of RC magnetic flux density, B with difference cross-section, geometries sizing and the number of turns by using Finite Element Method (FEM). Commonly, there are three types of RC widely used; rectangular, circular and oval. Each of these cross-sections has different characteristics in term of performance. The results have shown that the rectangular cross-section is better than oval and circular cross-section based on the number of magnetic flux density.


2016 ◽  
Vol 14 (1) ◽  
pp. 196-210 ◽  
Author(s):  
Mohammad Sadak Ali Khan ◽  
A. Suresh ◽  
N. Seetha Ramaiah

Purpose – The purpose of this paper is to evaluate the performance of the semi-active fluid damper. It is recognized that the performance of such a damper depends upon the magnetic and hydraulic circuit design. These dampers are generally used to control the vibrations in various applications in machine tools and robots. The present paper deals with the design of magneto-rheological (MR) damper. A finite element model is built to analyze and understand the performance of a 2D axi-symmetric MR damper. Various configurations of damper with modified piston ends are investigated. The input current to the coil and the piston velocity are varied to evaluate the resulting change in magnetic flux density (B), magnetic field (H), field dependent yield stress and magnetic force vectors. The simulation results of the various configurations of damper show that higher magnetic force is associated with plain piston ends. The performance of filleted piston ends is superior to that of other configurations for the same magnitude of coil current and piston velocity. Design/methodology/approach – The damper design is done based on the fact that mechanical energy required for yielding of MR fluid increases with increase in applied magnetic field intensity. In the presence of magnetic field, the MR fluid follows Bingham’s plastic flow model, given by the equation τ = η γ•+τ y (H) τ > τ y . The above equation is used to design a device which works on the basis of MR fluid. The total pressure drop in the damper is evaluated by summing the viscous component and yield stress component which is approximated as ΔP = 12ηQL/g3W + CτyL/g, where the value of the parameter, C ranges from a minimum of 2 (for ΔPτ ΔPη less than approximately 1) to a maximum of 3 (for ΔPτ/ΔPη greater than approximately 100). To calculate the change in pressure on either side of the piston within the cylinder, yield stress is required which is obtained from the graph of yield stress vs magnetic field intensity provided by Lord Corporation for MR fluid −132 DG. Findings – In this work, three different finite element models of MR damper piston are analyzed. The regression equations, contour plots and surface plots are obtained for different parameters. This study can be used as a reference for selecting the parameters for meeting different requirements. It is observed from the simulation of these models that the plain ends model gave optimum magnetic force and 2D flux lines with respect to damper input current. This is due to the fact that the plain ends model has more area when compared with that of other models. It is also observed that filleted ends model gave optimum magnetic flux density and yield stress. As there is reduced pole length in the filleted ends model, the MR fluid occupies vacant area, and hence results in increased flux density and yield shear stress. The filleted ends assist the formation of dense magnetic flux lines thereby increasing the flux density and yield stress. This implies that higher load can be carried by the filleted ends damper even with a smaller size. Originality/value – This work is carried out to manufacture different capacities of the dampers. This can be applied as vibration controls.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2522
Author(s):  
Guangdou Liu ◽  
Shiqin Hou ◽  
Xingping Xu ◽  
Wensheng Xiao

In the linear and planar motors, the 1D Halbach magnet array is extensively used. The sinusoidal property of the magnetic field deteriorates by analyzing the magnetic field at a small air gap. Therefore, a new 1D Halbach magnet array is proposed, in which the permanent magnet with a curved surface is applied. Based on the superposition of principle and Fourier series, the magnetic flux density distribution is derived. The optimized curved surface is obtained and fitted by a polynomial. The sinusoidal magnetic field is verified by comparing it with the magnetic flux density of the finite element model. Through the analysis of different dimensions of the permanent magnet array, the optimization result has good applicability. The force ripple can be significantly reduced by the new magnet array. The effect on the mass and air gap is investigated compared with a conventional magnet array with rectangular permanent magnets. In conclusion, the new magnet array design has the scalability to be extended to various sizes of motor and is especially suitable for small air gap applications.


2010 ◽  
Vol 129-131 ◽  
pp. 692-696
Author(s):  
Jian Bing Meng ◽  
Xiao Juan Dong ◽  
Chang Ning Ma

A mathematical model was developed to describe the oscillating amplitude of the plasma arc injected transverse to an external transverse alternating magnetic field. The characteristic of plasma arc under the external transverse alternating magnetic field imposed perpendicular to the plasma current was discussed. The effect of processing parameters, such as flow rate of working gas, arc current, magnetic flux density and the standoff from the nozzle to the workpiece, on the oscillation of plasma arc were also analyzed. The results show that it is feasible to adjust the shape of the plasma arc by the transverse alternating magnetic field, which expands the region of plasma arc thermal treatment upon the workpiece. Furthermore, the oscillating amplitude of plasma arc decreases with decrease of the magnetic flux density. Under the same magnetic flux density, more gas flow rate, more arc current, and less standoff cause the oscillating amplitude to decrease. The researches have provided a deeper understanding of adjusting of plasma arc characteristics.


2019 ◽  
Vol 9 (3) ◽  
pp. 22
Author(s):  
António Roque ◽  
Duarte M. Sousa ◽  
Pedro Sebastião ◽  
Elmano Margato ◽  
Gil Marques

This paper describes an innovative solution for the power supply of a fast field cycling (FFC) nuclear magnetic resonance (NMR) spectrometer considering its low power consumption, portability and low cost. In FFC cores, the magnetic flux density must be controlled in order to perform magnetic flux density cycles with short transients, while maintaining the magnetic flux density levels with high accuracy and homogeneity. Typical solutions in the FFC NMR literature use current control to get the required magnetic flux density cycles, which correspond to an indirect magnetic flux density control. The main feature of this new relaxometer is the direct control of the magnetic flux density instead of the magnet current, in contrast with other equipment available in the market. This feature is a great progress because it improves the performance. With this solution it is possible to compensate magnetic field disturbances and parasitic magnetic fields guaranteeing, among other possibilities, a field control below the earth magnetic field. Experimental results validating the developed solution and illustrating the real operation of this type of equipment are shown.


Author(s):  
Seok Woo Lee ◽  
Seung S. Lee

In this paper, PDMS membrane for a large displacement is fabricated by new fabrication process which can be integrated with electrical components on substrates fabricated by conventional microfabrication processes and the performance of the membrane using electromagnetism was evaluated. Rectangular PDMS membranes are designed as 2mm and 3mm in width, respectively and are actuated by Lorentz force induced by current paths spread on the membrane. The PDMS membrane is fabricated by reducing a viscosity of uncured PDMS with dilution and spin coating on the substrate on which electric components generating Lorentz force. Finally, PDMS membrane including electric components is opened by a bulk micromachining. The device is tested in magnetic field induced by Nd-Fe-B magnet whose magnetic flux density is 90G. When applied currents are 20, 25, and 30mA, the maximum deflections of membranes are 1.21, 3.07, and 20.2μm for 1.5mm width membrane and 3.34, 31.0, and 50.9μm for width 3mm membrane, respectively. The large displacement PDMS membrane actuator has potentially various applications such as fluidics, optics, acoustics, and electronics. Currently, we are planning to measure the optical performance of the actuator as a focal tunable liquid lens.


Sign in / Sign up

Export Citation Format

Share Document