scholarly journals FFC NMR Relaxometer with Magnetic Flux Density Control

2019 ◽  
Vol 9 (3) ◽  
pp. 22
Author(s):  
António Roque ◽  
Duarte M. Sousa ◽  
Pedro Sebastião ◽  
Elmano Margato ◽  
Gil Marques

This paper describes an innovative solution for the power supply of a fast field cycling (FFC) nuclear magnetic resonance (NMR) spectrometer considering its low power consumption, portability and low cost. In FFC cores, the magnetic flux density must be controlled in order to perform magnetic flux density cycles with short transients, while maintaining the magnetic flux density levels with high accuracy and homogeneity. Typical solutions in the FFC NMR literature use current control to get the required magnetic flux density cycles, which correspond to an indirect magnetic flux density control. The main feature of this new relaxometer is the direct control of the magnetic flux density instead of the magnet current, in contrast with other equipment available in the market. This feature is a great progress because it improves the performance. With this solution it is possible to compensate magnetic field disturbances and parasitic magnetic fields guaranteeing, among other possibilities, a field control below the earth magnetic field. Experimental results validating the developed solution and illustrating the real operation of this type of equipment are shown.

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2522
Author(s):  
Guangdou Liu ◽  
Shiqin Hou ◽  
Xingping Xu ◽  
Wensheng Xiao

In the linear and planar motors, the 1D Halbach magnet array is extensively used. The sinusoidal property of the magnetic field deteriorates by analyzing the magnetic field at a small air gap. Therefore, a new 1D Halbach magnet array is proposed, in which the permanent magnet with a curved surface is applied. Based on the superposition of principle and Fourier series, the magnetic flux density distribution is derived. The optimized curved surface is obtained and fitted by a polynomial. The sinusoidal magnetic field is verified by comparing it with the magnetic flux density of the finite element model. Through the analysis of different dimensions of the permanent magnet array, the optimization result has good applicability. The force ripple can be significantly reduced by the new magnet array. The effect on the mass and air gap is investigated compared with a conventional magnet array with rectangular permanent magnets. In conclusion, the new magnet array design has the scalability to be extended to various sizes of motor and is especially suitable for small air gap applications.


2010 ◽  
Vol 129-131 ◽  
pp. 692-696
Author(s):  
Jian Bing Meng ◽  
Xiao Juan Dong ◽  
Chang Ning Ma

A mathematical model was developed to describe the oscillating amplitude of the plasma arc injected transverse to an external transverse alternating magnetic field. The characteristic of plasma arc under the external transverse alternating magnetic field imposed perpendicular to the plasma current was discussed. The effect of processing parameters, such as flow rate of working gas, arc current, magnetic flux density and the standoff from the nozzle to the workpiece, on the oscillation of plasma arc were also analyzed. The results show that it is feasible to adjust the shape of the plasma arc by the transverse alternating magnetic field, which expands the region of plasma arc thermal treatment upon the workpiece. Furthermore, the oscillating amplitude of plasma arc decreases with decrease of the magnetic flux density. Under the same magnetic flux density, more gas flow rate, more arc current, and less standoff cause the oscillating amplitude to decrease. The researches have provided a deeper understanding of adjusting of plasma arc characteristics.


Author(s):  
Seok Woo Lee ◽  
Seung S. Lee

In this paper, PDMS membrane for a large displacement is fabricated by new fabrication process which can be integrated with electrical components on substrates fabricated by conventional microfabrication processes and the performance of the membrane using electromagnetism was evaluated. Rectangular PDMS membranes are designed as 2mm and 3mm in width, respectively and are actuated by Lorentz force induced by current paths spread on the membrane. The PDMS membrane is fabricated by reducing a viscosity of uncured PDMS with dilution and spin coating on the substrate on which electric components generating Lorentz force. Finally, PDMS membrane including electric components is opened by a bulk micromachining. The device is tested in magnetic field induced by Nd-Fe-B magnet whose magnetic flux density is 90G. When applied currents are 20, 25, and 30mA, the maximum deflections of membranes are 1.21, 3.07, and 20.2μm for 1.5mm width membrane and 3.34, 31.0, and 50.9μm for width 3mm membrane, respectively. The large displacement PDMS membrane actuator has potentially various applications such as fluidics, optics, acoustics, and electronics. Currently, we are planning to measure the optical performance of the actuator as a focal tunable liquid lens.


Author(s):  
Ping-Hsun Lee ◽  
Jen-Yuan (James) Chang

Abstract In this paper we proposed a platform for measuring shear force of magnetorheological (MR) fluid by which the relationship of yield stress and magnetic flux density of specific material can be determined. The device consisted of a rotatable center tube in a frame body and the magnetic field was provided by two blocks of permanent magnets placed oppositely outside the frame body. The magnitude and direction of the magnetic field were manipulated by changing the distance of the two permanent magnets from the frame body and rotating the center tube, respectively. For determining the magnetic field of the device, we adopted an effective method by fitting the FEM (finite element method) result to the measured one and then rebuilt the absent components to approximate the magnetic field, which was hardly to be measured simultaneously as different device setup were required. With the proposed platform and analytical methods, the drawing shear force and the corresponding yield stress contributed by MR fluid could be evaluated in respect to the magnitude and direction of given magnetic flux density with acceptable accuracy for specific designing purposes without a large, complex, and expensive instrument.


1999 ◽  
Vol 3 (2) ◽  
pp. 157-161 ◽  
Author(s):  
Yunbo Zhong ◽  
Zhongming Ren ◽  
Kang Deng ◽  
Guochang Jiang ◽  
Kuangdi Xu

2014 ◽  
Vol 565 ◽  
pp. 133-137
Author(s):  
Athirot Mano ◽  
Wisut Titiroongruang

In a measurement of magnetic flux density with high accuracy by using Hall effect sensor must be considered position of Hall sensor, that perfect perpendicular with magnetic flux line for measurement. Only one Hall element can cause measuring error. Therefore, this paper presents an application of independent directional magnetic field measurement technique on two dimensions for high accuracy magnetometer. It is presented by using two Hall sensors locate perpendicular to each other and use the relation of the two voltage output signal from both Hall sensors to calculate constant Hall voltage and Magnetic flux density with high accuracy by using trigonometric function with Lab-View programming. And as the result of experiment, this technique can reduce the limitation in term of this angle in the range magnetic flux density can be measured 0-1800 gauss. A calibration curve of this system compare with standard Gauss meter shows the coefficient of determination (R2) equal to 1 and has the accuracy percentage as less than 0.5%.


Author(s):  
Gui-Ping Zhu ◽  
Nam-Trung Nguyen

This paper reports the numerical and experimental investigation on magnetic particle concentration in a uniform magnetic field. The flow system consists of water-based ferrofluid and glycerol/DI water mixture streams. Two regimes were observed with spreading and mixing phenomena. With a low magnetic field strength, the spread of magnetic particles is caused by improved diffusion migration. With a relatively high field strength, instability at the interface would occur due to the mismatch in magnetization of the fluid streams. The transport of magnetic particles is induced by chaotic mixing of the fluids caused by a secondary flow. The mixing phenomena are characterized by magnetic flux density. For configuration with flow rate and viscosity ratio (between diamagnetic and magnetic streams) being set at 1 and 0.5, the mixing efficiency analyzed based on magnetic particles concentration increases approximately by 0.3 at around 3.5 mT. This value of magnetic flux density indicates the requirement on instability inception. The mixing efficiency increases with magnetic flux density increases further. Complete mixing can be achieved with a magnetic flux density at around 10 mT. The magnetic approach offers a wireless, heat-free and pH-independent solution for a lab-on-a-chip system.


Author(s):  
Alireza Hekmati ◽  
Siamak Arzanpour

This paper presents a mathematical modeling of a modified voice coil generator, which consists of a moving coil within a fixed magnetic circuit. The simulation has been done with Comsol Multiphysics software, which is a powerful tool to demonstrate the pattern of magnetic field and calculate the induced current in the coil. In our simulations, the magnetic circuit consists of the magnetic conductor and the air gap. In this analysis, the magnetic flux density and the magnetic field intensity are calculated. Moreover, through calculation of the total reluctance of the magnetic circuit and employing the ohm’s law for magnetic circuits, the effect of the length and cross section of the total circuit on the magnetic flux are investigated. Finally, a pattern for the magnetic flux density are demonstrated and the simulation result indicates that the magnetic field is well concentrated on the coil area, therefore this prototype can capture and convert most of the kinetic energy to electricity. A prototype has been fabricated and tested on the shaker. The experimental results indicate that this setup is able to produce the maximum voltage of 0.326 V and the peak power equal to 2.605 mW in 35 Hz frequency and 1 mm peak to peak amplitude.


2013 ◽  
Vol 811 ◽  
pp. 347-352 ◽  
Author(s):  
Athirot Mano ◽  
Narin Atiwongsangthong ◽  
Wisut Titiroongruang

The independent directional magnetic field measurement is a new technique for magnetic flux density measurement with high accuracy. This technique can reduce the limitation in term of angle that magnetic flux lines interact with Hall sensors. However, the original system limits the uniformity and symmetry of magnetic field patterns, which can cause an error for measurement system. Therefore, the aim of this research is to present the method to increase measurement accuracy of system, by improve magnetic field uniformity which can be done by using electromagnet instead of permanent magnet. The system is also improved the mechanical circle motion by using stepping motor, it is used to rotate Hall sensors in magnetic field which is generated by electromagnet. The result from experiment has shown of this method that can reduce the error percentage as 5% compare with original system. This method is shown 0.99997 of coefficient of determination, which represents to accuracy in magnetic flux density measurement range 0-1350 Gauss.


Sign in / Sign up

Export Citation Format

Share Document